0745745Q熱電偶輸出卡件
跳閘命令的分配(見(jiàn)第5.5.4.3節(jié)。)
用于分配跳閘命令的參數(shù)分組如下:“CB命令”子菜單。
輸出信號(hào)的分配取決于單個(gè)或三相跳閘已設(shè)置(參數(shù)“跳閘模式”)。在里面
在三相跳閘的情況下,三個(gè)跳閘輸出為分配給相同的輔助跳閘繼電器。單相跳閘(“跳閘模式”設(shè)置為“1PhTrip”或“3PhTripDel3”)需要三個(gè)單獨(dú)的輔助跳閘繼電器,即保護(hù)必須
配備至少兩個(gè)316DB61/62型二進(jìn)制I/O單元。3.5.31.12.信號(hào)(見(jiàn)第5.5.4.2節(jié)。)
將二進(jìn)制輸出分配給輔助信號(hào)繼電器的參數(shù)分組在“信號(hào)”子菜單中。一些信號(hào)輸出鎖存,直到全距離保護(hù)
功能復(fù)位(即,直到“啟動(dòng)R+S+T”復(fù)位,自動(dòng)重合閘(自動(dòng)重合閘)A、 應(yīng)用
該功能可配置為單相或三相自動(dòng)重合閘。該裝置可與三種保護(hù)功能(距離、縱向差動(dòng)和電流)中的任何一種一起運(yùn)行,并且內(nèi)部或外部同步檢查功能。
然而,額外的標(biāo)準(zhǔn)FUPLA邏輯T142詳細(xì)說(shuō)明在文件中,1KHF600220對(duì)于1?斷路器應(yīng)用中的單相重合閘是必要的。B、 特征最多4次快速或慢速重合閘嘗試第一個(gè)循環(huán),最多4個(gè)可單獨(dú)配置的單個(gè)和/或
三相重合閘嘗試
每個(gè)重合閘循環(huán)的獨(dú)立運(yùn)行指示器寬死區(qū)時(shí)間設(shè)置范圍
控制同步檢查裝置旁路的規(guī)定,以及通過(guò)外部信號(hào)延長(zhǎng)第一區(qū)域的死區(qū)時(shí)間
在以下過(guò)程中,對(duì)不斷變化的故障條件的明確響應(yīng):死區(qū)時(shí)間(不斷演變的故障)
邏輯1。第二。主保護(hù)(冗余),雙工主/從方案對(duì)信號(hào)名稱的注釋:專門用于冗余或雙工方案的I/O信號(hào)在其名稱中分別包括圖“2”和“3”。
屬于基本配置(1保護(hù))的信號(hào)
功能和1自動(dòng)重合閘功能)的名稱中不一定包含圖“1”。
參數(shù)說(shuō)明:將軍朗納普定義運(yùn)行函數(shù)的處理單元
Allocation of tripping commands
(see Section 5.5.4.3.)
The parameters for allocating tripping commands are grouped in
the ‘CB COMMANDS’ sub-menu.
The allocation of the output signals depends on whether single
or three-phase tripping has been set (parameter ‘TripMode'). In
the case of three-phase tripping, the three tripping outputs are
allocated to the same auxiliary tripping relay. Single-phase tripping ('TripMode’ set to ‘1PhTrip’ or ‘3PhTripDel3') requires three
separate auxiliary tripping relays, i.e. the protection has to be
equipped with at least two binary I/O units Type 316DB61/62.
3.5.31.12. Signals
(see Section 5.5.4.2.)
The parameters for allocating binary outputs to auxiliary signalling relays are grouped in the ‘SIGNALLING’ sub-menu.
Some signalling outputs latch until the entire distance protection
function resets (i.e. until ‘Start R+S+T’ resets,Auto-reclosure (Autoreclosure)
A. Application
The function can be configured for single or three-phase autoreclosure.
The unit can operate in conjunction with any of the three protection functions (distance, longitudinal differential and current) and
either an internal or external synchrocheck function.
However, an additional standard FUPLA logic T142 as detailed
in the document 1KHF600220 is necessary for single-phase reclosing in 1? breaker applications.
B. Features
up to 4 fast or slow reclosure attempts
first cycle with up to 4 individually configurable single and/or
three-phase reclosure attempts
independent operating indicators for each reclosure cycle
wide dead time setting range
provision to control bypassing of the synchrocheck unit and
extending the dead time for the first zone by external signals
clearly defined response to changing fault conditions during
the dead time (evolving faults)
Logic for 1st. and 2nd. main protection (redundant), duplex
and master/follower schemes Remarks on the signal designations:
The I/O signals specifically for redundant or duplex schemes include the figure ‘2’, respectively ‘3’ in their designations.
The signals belonging to the basic configuration (1 protection
function and 1 auto-reclosure function) do not necessarily include the figure ‘1’ in their designations.
Explanations of parameters:
GENERAL
RunOnCPU