中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗(yàn),請(qǐng)點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪問(wèn)瑞昌明盛自動(dòng)化設(shè)備有限公司網(wǎng)站!

圖片名

全國(guó)訂購(gòu)熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

SYHNC100-NIB-23/W-24-P-D-E23-A012

SYHNC100-NIB-23/W-24-P-D-E23-A012

SYHNC100-NIB-23/W-24-P-D-E23-A012伺服模塊在一個(gè)工業(yè)區(qū)或更大的工業(yè)場(chǎng)地。然而,如果機(jī)器配備交流驅(qū)動(dòng)器,在住宅或小型工業(yè)中運(yùn)行區(qū)域和無(wú)線電干擾抑制變得必要,則符合DIN VDE 0875第節(jié)的B類(lèi)限值1、3和11或EN 55011、EN 55014、EN 50081、CISPR 11和CISPR 14是通過(guò)安裝噪音過(guò)濾器直接粘附在機(jī)器上,該過(guò)濾器:INDRAMAT建議...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

SYHNC100-NIB-23/W-24-P-D-E23-A012

    微信圖片_20220907175947.jpg

    SYHNC100-NIB-23/W-24-P-D-E23-A012伺服模塊

    在一個(gè)工業(yè)區(qū)或更大的工業(yè)場(chǎng)地。然而,如果機(jī)器配備交流驅(qū)動(dòng)器,在住宅或小型工業(yè)中運(yùn)行區(qū)域和無(wú)線電干擾抑制變得必要,則符合DIN VDE 0875第節(jié)的B類(lèi)限值

    1、3和11或EN 55011、EN 55014、EN 50081、CISPR 11和CISPR 14是通過(guò)安裝噪音過(guò)濾器直接粘附在機(jī)器上,該過(guò)濾器:INDRAMAT建議接入電源電纜。

    當(dāng)電機(jī)電源電纜長(zhǎng)度較長(zhǎng)時(shí),進(jìn)一步建議:使用了電纜,并且這些電機(jī)電源電纜沒(méi)有在金屬中布線套管

    –使用屏蔽電纜,甚至更好,–這些電纜應(yīng)敷設(shè)在接地金屬管道或接地電纜中軸內(nèi)襯金屬。注:僅INDRAMAT驅(qū)動(dòng)器所需的調(diào)試步驟在此描述。機(jī)器制造商必須按照以下要求提交整個(gè)機(jī)器或設(shè)施的調(diào)試流程:個(gè)人申請(qǐng)。危險(xiǎn)源:?端子L1、L2和L3處的高電源電壓?L+時(shí)的高鏈路電路電壓,L-?端子A1、A2、A3和電機(jī)電纜插件處的電機(jī)電壓高終端安全覆蓋所有熱部件,以避免任何意外接觸!

    用塑料蓋蓋住電源連接!?如有可能,關(guān)閉控制柜。

    授權(quán)電氣人員必須固定打開(kāi)的電氣控制柜、可接近的電氣設(shè)施和設(shè)備,可能高溫,防止危險(xiǎn)人員接觸。

    ?檢查所有保護(hù)導(dǎo)體的固定連接電氣設(shè)備和電機(jī)符合連接計(jì)劃!僅允許在以下情況下進(jìn)行操作:連接的保護(hù)導(dǎo)體在其適當(dāng)位置設(shè)備和電機(jī)插頭,即使用于快速測(cè)量或用于測(cè)試目的。防止與電源間接接觸:采取必要的保護(hù)措施防止接觸它們是針對(duì)當(dāng)前的電源情況而規(guī)定的。F1保護(hù)功能(故障電流保護(hù)功能)不能用于交流驅(qū)動(dòng)器!接觸防護(hù)必須:以其他方式固定,例如過(guò)電流保護(hù)特征(符合DIN VDE 0160第6.5.2.4節(jié))。由于故障,存在意外移動(dòng)的危險(xiǎn)?布線和電纜中?在NC或NC程序中

    ?在測(cè)量值編碼器(如增量編碼器)中

    ?在機(jī)器運(yùn)行中,例如關(guān)閉安全功能和監(jiān)視器檢查操作和設(shè)置。

    這些故障可能會(huì)發(fā)生?調(diào)試后,但,?在正常運(yùn)行期間的不確定時(shí)間后。

    Suppression of radio interference is generally not needed within an

    industrial area or over larger industrial sites. If, however, machinery

    equipped with AC drives is operated in residential or smaller industrial

    areas and suppression of radio interference becomes necessary, then

    the limiting values of Class B in accordance with DIN VDE 0875, Sections

    1, 3 and 11 or EN 55011, EN 55014, EN 50081, CISPR 11, CISPR 14 are

    adhered to directly at the machine by mounting a noise filter which

    INDRAMAT recommends into the mains cable.

    It is further recommended when longer cable lengths of the motor power

    cable are used and those motor power cables are not routed in a metal

    casing

    – that a shielded cable be used, or even better,

    – that these be routed in grounded metal pipes or in grounded cable

    shafts lined with metal.Note: The commissiong steps required for the INDRAMAT drives only

    are described here. The machine manufacturer must submit the commissioning process for the entire machine or facility as required for the

    individual application.Sources of Danger:

    ? high mains voltage at terminals L1, L2, L3

    ? high link circuit voltage at L+, L-

    ? high motor voltage at terminals A1, A2, A3 and motor cable plug-in

    terminals.? Securely cover all hot parts to avoid any accidental contact!

    Cover the power connections with plastic lids!

    ? Close the control cabinet, if possible. Authorized electrical

    personnel must secure open electrical control cabinets, accessible electrical facilities and equipment, which could be

    hot, against contact by personnel at risk.

    ? Check the fixed connection of the protective conductor of all

    the electrical equipment and motors, in accordance with the

    connection plans! Operation is only permitted with firmly

    attached protective conductors in their proper positions on

    equipment and motor plug, even for quick measuring or

    testing purposes.Protection against indirect contact with the mains:

    Secure against contact by taking the necessary protective measures

    which are prescribed for the mains situation at hand.

    An F1 protective feature (fault current protective feature) cannot be used for the AC drives! Protection against contact must

    be secured in some other way, e.g., an over-current protective

    feature (in accordance with DIN VDE 0160, Section 6.5.2.4).

    Danger from unwanted movement exists because of faults

    ? in the wiring and cables

    ? in the NC or NC program

    ? in the measuring value encoders such as the incremental encoder,

    ? in the operation of the machine, e.g., switching-off safety functions and

    monitors to check operation and setting.

    These faults can occur

    ? right after commissioning, but also,

    ? after an indeterminate length of time during normal operation.

    品牌:REXRTOH

    型號(hào):SYHNC100-NIB-23/W-24-P-D-E23-A012

    產(chǎn)地:美國(guó)

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號(hào)