87TS50R1214 GKWE驅(qū)動(dòng)控制卡
額定625…1250 A的控制器額定電流為625…1250 A的控制器需要共同控制才能正常工作活動(dòng)控制電源通過(guò)接線(xiàn)板連接到產(chǎn)品CP1,位于端子1和4。該單一連接點(diǎn)為控制器供電模塊、接觸器和風(fēng)扇??刂齐娫幢仨殲?10/120V AC或230/240V AC,僅50/60 Hz。至少800 VA的控制電源必修的??刂齐娫匆蟀刂颇K(75 VA),旁路接觸器(最大526 VA)和風(fēng)扇功率(150 VA)。
根據(jù)具體應(yīng)用,附加控制電路變壓器可能需要VA容量。
控制額定功率為230/240V AC的裝置有一個(gè)欠壓繼電器安裝。2014年之前建造的機(jī)組可能在欠壓繼電器。如果有電位計(jì),則必須對(duì)其進(jìn)行設(shè)置根據(jù)圖36,2014年以后建造的機(jī)組可能不會(huì)電位計(jì),因?yàn)樵O(shè)置在內(nèi)部編程到欠壓繼電器,無(wú)需調(diào)整。本節(jié)涵蓋了您需要解決的一些注意事項(xiàng),具體取決于在您的應(yīng)用程序上。
保護(hù)模塊您應(yīng)該安裝一個(gè)包含MOV(金屬)的保護(hù)模塊(見(jiàn)圖65氧化物變阻器),以保護(hù)SMC Flex電源組件免受電氣影響瞬態(tài)和/或電氣噪聲。您可以安裝額定電壓為200…600V的保護(hù)模塊控制器來(lái)保護(hù)來(lái)自電氣瞬變的功率元件。
保護(hù)模塊卡夾線(xiàn)路上產(chǎn)生的電壓瞬變
以防止此類(lèi)浪涌損壞SCR。強(qiáng)烈建議使用MOV,因?yàn)?80V和600V MOV分別提供1400V和1600V的最大保護(hù)??赡軙?huì)出現(xiàn)兩種情況,表明需要用于使用保護(hù)模塊。1.瞬態(tài)峰值-瞬態(tài)峰值通常會(huì)出現(xiàn)在線(xiàn)路上為SMC Flex控制器饋電或從SMC Flex饋電負(fù)載控制器。當(dāng)設(shè)備帶有開(kāi)路的載流電感。當(dāng)觸點(diǎn)斷開(kāi)電路。這些示例包括輕載電機(jī)、變壓器、螺線(xiàn)管、全電壓起動(dòng)器和機(jī)電制動(dòng)器。閃電也會(huì)導(dǎo)致尖峰。
2.快速上升的Wavefronts-如果SMC Flex控制器安裝在存在快速上升波前的系統(tǒng),盡管不是可能需要高峰值電壓、保護(hù)模塊。閃電也會(huì)導(dǎo)致這種類(lèi)型的響應(yīng)。此外,如果控制器與其他SCR設(shè)備(如AC/DC)在同一總線(xiàn)上驅(qū)動(dòng)器、感應(yīng)加熱設(shè)備或焊接設(shè)備)、點(diǎn)火這些設(shè)備中的SCR可能會(huì)產(chǎn)生噪音
Controllers rated 625…1250 A
Controllers that are rated 625…1250 A require common control for proper operation. Control power is connected to the product through terminal block CP1, at terminals 1 and 4. This single connection point feeds the control module, contactors, and fans. Control power must be supplied as 110/120V AC or 230/240V AC, 50/60 Hz only. A control power source of at least 800 VA is required. The control power requirements include the control module (75 VA), bypass contactors (526 VA max), and fan power (150 VA). Depending on the specific application, additional control circuit transformer VA capacity may be required. Units with a control power rating of 230/240V AC have an undervoltage relay installed. Units built prior to 2014 may have potentiometers on the undervoltage relay. If potentiometers are present, you must set them according to Figure 36. Units built later than 2014 may not have potentiometers, because the settings are programmed internally to the undervoltage relay and no adjustment is required.
This section covers some considerations
that you need to address, depending on your application. Protective Modules You should install a protective module (see Figure 65) containing MOVs (Metal Oxide Varistors) to protect the SMC Flex power components from electrical transients and/or electrical noise. You can install protective modules controllers rated from 200…600V to protect the power components from electrical transients. The protective modules clip voltage transients that are generated on the lines to prevent such surges from damaging the SCRs. The use of MOVs is highly recommended, because 480V and 600V MOVs offer maximum protection of 1400V and 1600V, respectively.
There are two general situations that may occur that could indicate the need for using the protective modules. 1. Transient Spikes — Transient spikes will typically occur on the lines feeding the SMC Flex controller or feeding the load from the SMC Flex controller. Transient spikes are created on the line when devices are attached with current- carrying inductances that are open-circuited. The energy stored in the magnetic field is released when the contacts open the circuit. Examples of these include lightly loaded motors, transformers, solenoids, full voltage starters, and electromechanical brakes. Lightning can also cause spikes. 2. Fast-rising Wavefronts — If the SMC Flex controller is installed on a system that has fast-rising wavefronts present, although not necessarily high peak voltages, protective modules may be needed. Lightning can also cause this type of response. Additionally, if the controller is on the same bus as other SCR devices (such as AC/DC drives, induction heating equipment, or welding equipment), the firing of the SCRs in those devices can cause noise.