A-B 80190-100-01-R光纖接口板

A-B 80190-100-01-R光纖接口板

產(chǎn)品內(nèi)容介紹A-B 80190-100-01-R光纖接口板1.禁止驅(qū)動(dòng)器連接或斷開(kāi)通信卡控制器試圖通過(guò)它配置安全速度監(jiān)視器模塊使用ADC。2.將安全速度監(jiān)視器模塊參數(shù)1[密碼]設(shè)置為模塊的當(dāng)前密碼。3.將安全速度監(jiān)視器模塊參數(shù)5[鎖定狀態(tài)]設(shè)置為“0”(解鎖)。4.將安全速度監(jiān)視器模塊參數(shù)6[操作模式]設(shè)置為“0”(程序)。5.如果安全速度監(jiān)視器模塊的當(dāng)前密碼不是“0”,則更改模塊的密碼設(shè)置為“0...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

A-B 80190-100-01-R光纖接口板

    產(chǎn)品內(nèi)容介紹

    A-B 80190-100-01-R光纖接口板

    1.禁止驅(qū)動(dòng)器連接或斷開(kāi)通信卡控制器試圖通過(guò)它配置安全速度監(jiān)視器模塊使用ADC。

    2.將安全速度監(jiān)視器模塊參數(shù)1[密碼]設(shè)置為模塊的當(dāng)前密碼。

    3.將安全速度監(jiān)視器模塊參數(shù)5[鎖定狀態(tài)]設(shè)置為“0”(解鎖)。

    4.將安全速度監(jiān)視器模塊參數(shù)6[操作模式]設(shè)置為“0”(程序)。

    5.如果安全速度監(jiān)視器模塊的當(dāng)前密碼不是“0”,則更改模塊的密碼設(shè)置為“0”

    6.將安全速度監(jiān)視器模塊參數(shù)1[密碼]設(shè)置為模塊的當(dāng)前密碼。

    7.將安全速度監(jiān)視器模塊參數(shù)13[新密碼]設(shè)置為“0”

    8.將安全速度監(jiān)視器模塊參數(shù)17[密碼命令]設(shè)置為“1”(更改PW)。

    9.取消禁止連接或重新連接電纜。

    控制器可以下載新配置,包括新配置暗語(yǔ)安裝安全速度監(jiān)視器模塊需要以下手動(dòng)步驟進(jìn)入運(yùn)行模式,生成配置簽名,并鎖定配置。

    更換安全速度監(jiān)視器時(shí),也需要執(zhí)行這些步驟帶有新的“開(kāi)箱即用”單元的模塊。

    監(jiān)測(cè)ADC進(jìn)度ADC過(guò)程完成所需的時(shí)間從秒到秒不等

    幾分鐘取決于幾個(gè)因素:

    ?為ADC啟用的外圍設(shè)備數(shù)量。

    ?如果驅(qū)動(dòng)器/外圍設(shè)備的配置簽名指示需要為給定端口執(zhí)行配置下載。

    ?Firmware Supervisor是否已啟用并需要升級(jí)驅(qū)動(dòng)器和/或任何外圍設(shè)備。

    ?如果20-750-S1安全速度監(jiān)視器選件模塊需要在其配置過(guò)程中使用手動(dòng)“步驟”。

    ?如果使用DeviceLogix程序(端口14)。

    啟用Firmware Supervisor后,啟動(dòng)可能需要相當(dāng)長(zhǎng)的時(shí)間。

    具有所有固件和參數(shù)都要更新,大約需要45…55分鐘。

    可以使用HIM、驅(qū)動(dòng)器軟件配置工具或通過(guò)HMI,可以觸發(fā)控制器程序的明確消息寫(xiě)入。

    為了滿(mǎn)足SIL CL3、PLe或Cat 4要求,用戶(hù)必須驗(yàn)證安全速度監(jiān)視器模塊中鎖定了正確的配置。

    查看驅(qū)動(dòng)器和安全速度監(jiān)視器模塊文檔以了解更多信息。

    作為配置過(guò)程的一部分,ADC可以自動(dòng)重置驅(qū)動(dòng)器。

    這是因?yàn)槟承﹨?shù)需要重置才能生效。

    如果是驅(qū)動(dòng)器被替換為現(xiàn)成的驅(qū)動(dòng)器,您通常會(huì)在中看到ADC過(guò)程中至少兩次復(fù)位,一次復(fù)位驅(qū)動(dòng)器中的參數(shù)(端口0),對(duì)于PowerFlex 755驅(qū)動(dòng)器,一個(gè)用于嵌入式EtherNet/IP適配器(端口13)。

    Monitoring ADC Progress

     The time it takes for the ADC process to complete will vary from seconds to several minutes depending on several factors: ? The number of peripherals enabled for ADC. ? If a configuration signature for the drive/peripheral indicates a configuration download needs to be performed for the given port. ? Whether Firmware Supervisor is enabled and needs to upgrade the drive and/or any peripherals. ? If a 20-750-S1 Safe Speed Monitor option module, which requires a manual ‘step’ in its configuration process, is used. ? If a DeviceLogix program (Port 14) is used. With the Firmware Supervisor enabled, startup can take quite a long time. With all firmware and parameters being updated, it takes approximately 45…55 minutes.1. Inhibit the drive’s connection—or disconnect the communication card through which the controller is trying to configure the Safe Speed Monitor Module using ADC. 2. Set Safe Speed Monitor Module parameter 1 [Password] to the Module’s current password. 3. Set Safe Speed Monitor Module parameter 5 [Lock State] to “0” (Unlock). 4. Set Safe Speed Monitor Module parameter 6 [Operating Mode] to “0” (Program). 5. If the Safe Speed Monitor Module’s current password is not “0,” change the password of the Module to “0.” 6. Set Safe Speed Monitor Module parameter 1 [Password] to the Module’s current password. 7. Set Safe Speed Monitor Module parameter 13 [New Password] to “0.”

    These steps can be performed with a HIM

    drive software configuration tool, or via an HMI that can trigger explicit message writes from the controller program. To meet SIL CL3, PLe, or Cat 4 requirements, the user must verify that the correct configuration is locked in the Safe Speed Monitor Module. See the drive and Safe Speed Monitor Module documentation for more information. 8. Set Safe Speed Monitor Module parameter 17 [Password Command] to “1” (Change PW). 9. Uninhibit the connection or reconnect the cable. The controller can download the new configuration, including the new password. The following manual steps are required to put the Safe Speed Monitor Module into Run mode, generate a configuration signature, and lock the configuration. These steps also need to be performed when replacing the Safe Speed Monitor Module with a new, “out of the box” unit.ADC can automatically reset the drive as part of the configuration process. This is done because some parameters require a reset before they take effect. If a drive is being replaced with an out-of-the-box drive, you will typically see at least two resets during the ADC process—one for the parameters in the drive (Port 0) and, for a PowerFlex 755 drive, one for the parameters in the embedded EtherNet/IP adapter (Port 13).

    d082d79904e378397cc59202556710a7.jpg

    f5a1d52084176089c442c690694264a9.jpg


    公司主營(yíng)產(chǎn)品圖展示

    微信圖片_20220913175441.jpg

    產(chǎn)品優(yōu)勢(shì)

    1:國(guó)外專(zhuān)業(yè)的供貨渠道,具有價(jià)格優(yōu)勢(shì)

    2:產(chǎn)品質(zhì)量保證,讓您售后無(wú)憂

    3:全國(guó)快遞包郵

    4:一對(duì)一服務(wù)

    公司主營(yíng)范圍簡(jiǎn)介

    PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動(dòng)監(jiān)測(cè)系統(tǒng)卡件,汽輪機(jī)控制系統(tǒng)模塊,燃?xì)獍l(fā)電機(jī)備件等,優(yōu)勢(shì)品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進(jìn)口工業(yè)零部件、歐美進(jìn)口模塊。

    產(chǎn)品廣泛應(yīng)用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機(jī)械、電子制造、汽車(chē)制造、塑膠機(jī)械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等


    品牌:A-B

    型號(hào):80190-100-01-R

    產(chǎn)地:美國(guó)

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號(hào)