中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過低,為保證更佳的瀏覽體驗,請點擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設(shè)備有限公司網(wǎng)站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

BENTLY 3300/16-04-01-01-00-00-00間隙監(jiān)視器

BENTLY 3300/16-04-01-01-00-00-00間隙監(jiān)視器

產(chǎn)品詳情介紹BENTLY 3300/16-04-01-01-00-00-00間隙監(jiān)視器確定發(fā)動機是否有故障。確認(rèn)燃油齒條未卡滯,連桿調(diào)整正確。確定燃油齒條是否快速跟隨執(zhí)行器輸入電壓。檢查超速保護裝置的運行情況。原動機僅在啟動時超速或產(chǎn)生過量煙霧。啟動燃油限制處于非活動狀態(tài)。通電后,如果MPU信號在不到1秒的時間內(nèi)清除,則可以繞過Fuel Limit(燃油限制)。啟動發(fā)動機前,接通2301A電源。2...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

BENTLY 3300/16-04-01-01-00-00-00間隙監(jiān)視器

    產(chǎn)品詳情介紹

    BENTLY 3300/16-04-01-01-00-00-00間隙監(jiān)視器

    確定發(fā)動機是否有故障。確認(rèn)燃油齒條未卡滯,連桿調(diào)整正確。確定燃油齒條是否快速跟隨執(zhí)行器輸入電壓。檢查超速保護裝置的運行情況。原動機僅在啟動時超速或產(chǎn)生過量煙霧。啟動燃油限制處于非活動狀態(tài)。通電后,如果MPU信號在不到1秒的時間內(nèi)清除,則可以繞過Fuel Limit(燃油限制)。啟動發(fā)動機前,接通2301A電源。2301A控制。如果控制裝置在速度設(shè)置完全逆時針(或在任何位置都不減少燃油)之前沒有降低執(zhí)行器電壓[T20(+)和T21(-)],則2301A控制裝置可能有故障,或速度范圍錯誤。如果電壓降低,檢查連桿或執(zhí)行器有無故障。原動機在額定速度下運行一段時間后超速。原動機。檢查原動機燃油系統(tǒng)是否正常工作。如果執(zhí)行器在超速期間向最小燃油方向移動,則問題出在燃油系統(tǒng)中。電磁拾波器和2301A控制。檢查轉(zhuǎn)速高于怠速至少1.0 Vrms時的電磁拾波器輸出電壓。如果磁性撿拾器出現(xiàn)故障并且超越故障轉(zhuǎn)速信號電路被禁用,則2301A控制裝置將需要最大燃油量。以額定速度手動控制原動機,并完全逆時針調(diào)整額定速度設(shè)置。如果輸出電壓不為零,請按照第2章所述檢查速度范圍開關(guān)調(diào)整是否正確。如果速度范圍適合應(yīng)用,請更換控制器。

    低速不由Low IDLE speed(低怠速)電位計調(diào)節(jié)。

    低怠速設(shè)置可能低于執(zhí)行器或原動機燃油擋塊的最小燃油位置。在這種情況下,執(zhí)行器的輸出電壓將為零。發(fā)動機將通過執(zhí)行器或原動機最小燃油擋塊保持在最小燃油位置。上述情況表明,應(yīng)通過連桿調(diào)整(柴油發(fā)動機)或低怠速調(diào)整螺釘(燃?xì)獍l(fā)動機)降低原動機最小燃油位置,或提高低怠速設(shè)置。如果上述操作不能解決問題,則2301A控制裝置可能有故障。當(dāng)觸點斷開時,額定觸點的故障閉合可能會保持在加速位置。如果額定觸點閉合工作,怠速控制損失可能是由于電路故障造成的。通常,低怠速的調(diào)整將改變原動機的速度,額定觸點閉合處于減速(斷開)位置。當(dāng)額定閉合觸點閉合時,低怠速的調(diào)整不應(yīng)影響原動機速度。警告:速度設(shè)置控件有足夠的范圍覆蓋斜坡,使原動機速度達到額定速度,同時仍處于低怠速模式(通過缺陷或切換)。因此,如果在T19打開的情況下將額定轉(zhuǎn)速設(shè)置調(diào)整為額定轉(zhuǎn)速,則間歇的額定觸點閉合可能會導(dǎo)致原動機超速。

    Determine if engine is malfunctioning. 

    Verify that fuel rack is not binding and linkage is properly adjusted. Determine if the fuel rack is quickly following the actuator input voltage. Check operation of overspeed protection device(s). Prime mover overspeeds or causes excessive smoke only on starts. Start Fuel Limit is inactive. On power up, Fuel Limit can be bypassed if MPU signal clears in less than 1 second. Power up 2301A before cranking engine. 2301A control. If the control does not cut back the actuator voltage [T20 (+) and T21 (–)] until the speed setting is completely counterclockwise (or does not reduce fuel at any position), the 2301A control may be faulty, or may have the wrong speed range. If the voltage is cut back, look for a problem in the linkage or actuator. Prime mover overspeeds after operating at rated speed for some time. Prime mover. Check for proper operation of prime-mover fuel system. If actuator moves toward minimum fuel during overspeed, problem is in fuel system. Magnetic pickup and 2301A control. Check the magnetic-pickup output voltage at speeds above idle-at least 1.0 Vrms. If magnetic pickup should fail and the override-failed-speed-signal circuit is disabled, the 2301A control will call for maximum fuel.Control the prime mover manually at rated speed and adjust the RATED SPEED setting fully counterclockwise. If the output voltage is not zero, check for proper speed range switch adjustment as described in Chapter 2. If speed range is correct for the application, replace the control.

    Low speed is not regulated by LOW IDLE SPEED potentiometer.

    The LOW IDLE SPEED setting may be below the minimum-fuel position of the actuator or prime-mover fuel stop. In this case, the output voltage to the actuator will be zero. The engine will be maintained at the minimum-fuel position by the actuator or the prime mover minimum-fuel stop. The conditions above indicate that the prime mover minimum-fuel position should be decreased by linkage adjustment (diesel engine) or low-idle set screw (gas engine), or the LOW IDLE SPEED setting should be raised. If the above action does not correct the problem, the 2301A control may be faulty.A faulty Close for Rated contact may remain in the accelerate position with the contact open. If the Close for Rated contact is operative, loss of idle control may be due to a faulty circuit. In general, adjustment of LOW IDLE SPEED will vary the speed of the prime mover with the Close for Rated contact in the decelerate (open) position. Adjustment of LOW IDLE SPEED should not affect prime mover speed when the Close for Rated contact is closed. WARNING The speed-setting controls have sufficient range to override the ramp and bring the prime mover speed up to rated while still In the low-idle mode (either by defect or switching). Therefore, a Close for Rated contact that is intermittent may cause the prime mover to overspeed if the RATED SPEED setting is adjusted for rated speed with T19 open.

    產(chǎn)品優(yōu)勢

    1:國外專業(yè)的供貨渠道,具有價格優(yōu)勢

    2:產(chǎn)品質(zhì)量保證,讓您售后無憂

    3:全國快遞包郵

    4:一對一服務(wù)

    公司主營范圍簡介

    PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動監(jiān)測系統(tǒng)卡件,汽輪機控制系統(tǒng)模塊,燃?xì)獍l(fā)電機備件等,優(yōu)勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進口工業(yè)零部件、歐美進口模塊。

    產(chǎn)品廣泛應(yīng)用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車制造、塑膠機械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等

    微信圖片_20211117105440.png

    品牌:BENTLY

    型號 :3300/16-04-01-01-00-00-00

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號