330106-05-30-05-02-00探頭傳感器
配置ID
包含一個(gè)唯一的六字符標(biāo)識(shí)符,當(dāng)配置下載到3500機(jī)架時(shí)輸入該標(biāo)識(shí)符。后端口機(jī)架接口輸入/輸出模塊上標(biāo)記為主機(jī)的端口,用于將3500機(jī)架連接到3500主機(jī)或3500機(jī)架菊花鏈連接到更靠近3500主機(jī)。I/O選項(xiàng)3500監(jiān)測(cè)系統(tǒng)可用的兩種機(jī)架接口I/O模塊是RS-232/RS-422 I/O模塊和調(diào)制解調(diào)器I/O模塊。RS-232/RS-422 I/O模塊包含一個(gè)9針主機(jī)連接器,該連接器包含RS-232或RS-422電平信號(hào),具體取決于I/O模塊開(kāi)關(guān)的位置。調(diào)制解調(diào)器I/O模塊有一個(gè)RJ11連接器,并包含一個(gè)內(nèi)部調(diào)制解調(diào)器。3配置信息3500/20操作和維護(hù)8外部調(diào)制解調(diào)器當(dāng)配置RS-232/RS-422輸入/輸出模塊時(shí),機(jī)架接口模塊直接支持以下外部調(diào)制解調(diào)器:無(wú)Hayes Ultra 9600 Hayes Optima 9600 Motorola FasTalkII 9600自定義初始化字符串設(shè)置和啟動(dòng)調(diào)制解調(diào)器的命令。如果從列表中選擇調(diào)制解調(diào)器,默認(rèn)初始化字符串將顯示在此字段中。如果選擇“自定義”,請(qǐng)根據(jù)調(diào)制解調(diào)器文檔中的信息輸入初始化字符串。字節(jié)超時(shí)在通信被認(rèn)為完成之前,通信線路必須空閑的字節(jié)次數(shù)。一字節(jié)時(shí)間是所選波特率的函數(shù)。
連接密碼
值的范圍為3至255。連接密碼提供對(duì)3500機(jī)架的只讀訪問(wèn)。如果此字段中輸入的密碼與機(jī)架配置軟件“連接”屏幕或數(shù)據(jù)采集/DDE服務(wù)器軟件“設(shè)置”屏幕中輸入的口令不匹配,則不允許與3500機(jī)架通信。該密碼存儲(chǔ)在機(jī)架接口模塊的非易失性存儲(chǔ)器中。配置密碼提供對(duì)3500機(jī)架的配置寫(xiě)入訪問(wèn)。如果此字段中輸入的密碼與機(jī)架配置軟件“下載”屏幕中輸入的口令不匹配,3500機(jī)架將不接受新配置。通過(guò)操作員顯示軟件更改3500機(jī)架中的設(shè)定值也需要該密碼。該密碼存儲(chǔ)在機(jī)架接口模塊的非易失性存儲(chǔ)器中。僅在編程模式下更改設(shè)置點(diǎn)如果鑰匙鎖處于編程模式位置,則僅允許更改任何監(jiān)視器中的設(shè)置點(diǎn)。如果鍵處于運(yùn)行位置,則不允許更改設(shè)定點(diǎn)。前端口機(jī)架接口模塊前面標(biāo)有配置端口的端口,主要用于通過(guò)個(gè)人計(jì)算機(jī)配置3500機(jī)架。該端口還可用于檢索機(jī)械數(shù)據(jù),以便使用數(shù)據(jù)采集/DDE服務(wù)器軟件和操作員顯示軟件進(jìn)行顯示。該端口僅支持RS-232,僅提供對(duì)一個(gè)機(jī)架的訪問(wèn)
Configuration ID
Contains a unique six character identifier that is entered when the configuration is downloaded to the 3500 rack. The port labeled Host on the Rear Port Rack Interface I/O Module that connects a 3500 rack to a 3500 host or a 3500 rack daisy chain to a 3500 host closer. The two types of Rack Interface I/O modules available with the I/O Option 3500 Monitoring System are RS-232/RS-422 I/O modules and modem I/O modules. The RS-232/RS-422 I/O module contains a 9-pin host connector that contains RS-232 or RS-422 level signals, depending on the position of the I/O module switch. The modem I/O module has an RJ11 connector and contains an internal modem. 3 Configuration information 3500/20 Operation and maintenance 8 External modemWhen configuring the RS-232/RS-422 I/O module, the Rack Interface Module directly supports the following external modems: no Hayes Ultra 9600 Hayes Optima 9600 Motorola FasTalkII 9600 custom initialization string settings and the command to start the modem. If you select a modem from the list, the default initialization string appears in this field. If you select Custom, enter the initialization string according to the information in the modem documentation. Byte timeout The number of bytes that the communication line must be idle before communication is considered complete. One byte time is a function of the selected baud rate.
Connection password
Values range from 3 to 255. The connection password provides read-only access to the 3500 rack. If the password entered in this field does not match the password entered in the Rack Configuration Software Connect screen or the Data Acquisition/DDE Server Software Setup screen, communication with the 3500 rack is not allowed. The password is stored in the nonvolatile memory of the Rack Interface Module. The configuration password provides configuration write access to the 3500 rack. If the password entered in this field does not match the password entered on the Download screen of the Rack Configuration Software, the 3500 rack will not accept the new configuration. This password is also required to change the settings in the 3500 rack through the operator display software. The password is stored in the nonvolatile memory of the Rack Interface Module. Changing setpoints only in programming modeIf the key lock is in the programming mode position, only changing setpoints in any monitor is allowed. If the key is in the RUN position, it is not allowed to change the setpoint. The port on the front of the Front Port Rack Interface Module that is marked with a configuration port is primarily used to configure a 3500 rack through a personal computer. This port can also be used to retrieve mechanical data for display using data acquisition/DDE server software and operator display software. This port only supports RS-232 and provides access to only one rack