EMERSON A6410 系統(tǒng)模塊卡件
重置默認(rèn)參數(shù)設(shè)置所有控制器都帶有默認(rèn)參數(shù)值,可通過I/O型號的示教過程和RS-485和can型號的串行命令更改這些默認(rèn)參數(shù)值。所有型號的默認(rèn)參數(shù)都可以通過以下步驟重置:1.關(guān)閉控制器電源。2.將DIP開關(guān)陣列S1上的開關(guān)8設(shè)置為on。3.打開控制器電源。4.將DIP開關(guān)陣列S1上的開關(guān)8設(shè)置為OFF。5.現(xiàn)在應(yīng)恢復(fù)默認(rèn)設(shè)置。功能描述-模擬模型圖3-模擬模型模擬控制器模型提供與目標(biāo)高度、寬度或位置成比例的4…20 mA或0…10V(電流或電壓可通過DIP開關(guān)選擇)輸出。輸出會自動(dòng)縮放到連接陣列的長度,因此大多數(shù)應(yīng)用程序不需要額外調(diào)整。需要定制輸出比例的應(yīng)用程序可使用“示教”按鈕。引腳列表表6顯示了主連接器J2上的引腳分配。表4-控制器主板狀態(tài)指示器狀態(tài)指示器描述顏色含義D1燈陣列正常關(guān)閉目標(biāo)存在或燈陣列未對齊綠色目標(biāo)不存在和燈陣列對齊綠色閃爍低裕度/光強(qiáng)度不足D2燈陣列狀態(tài)關(guān)閉目標(biāo)不存在紅色目標(biāo)存在紅色閃爍系統(tǒng)D3輸出1關(guān)閉輸出1關(guān)閉綠色輸出1激活D4輸出2關(guān)閉輸出2非激活綠色輸出2激活D5輸入1關(guān)閉輸入1非激活綠色輸入1激活D6輸入2關(guān)閉輸入2非激活綠輸入2激活D7電源關(guān)閉電源關(guān)閉綠色電源打開表5-控制器主PCB電位計(jì)調(diào)整電位計(jì)描述方向限值電位計(jì)1(1)(1)電位計(jì)1未用于模擬控制器型號。Reset Default Parameter Settings All controllers are shipped with default parameter values that can be changed through the teach process for the I/O model and through serial commands for the RS-485 and CAN models. The default parameters can be reset in all models by following this procedure: 1. Turn off controller power. 2. Set switch 8 on DIP switch array S1 to ON. 3. Turn on controller power. 4. Set switch eight on DIP switch array S1 to OFF. 5. Default settings should now be restored. Functional Description — Analog Model Figure 3 - Analog Model The analog controller model offers either 4…20 mA or 0…10V (current or voltage selectable via DIP switch) output proportional to target height, width, or position. The output is automatically scaled to the length of the connected arrays, so most applications do not require additional adjustments. A Teach button is available for applications that require customized scaling of the output. Pin Listings Table 6 shows the allocation of pins on the main connector, J2. Table 4 - Controller Main Board Status Indicators Status Indicator Description Color Meaning D1 Light array OK Off Target present or light arrays not aligned Green Target not present and light arrays aligned Green flashing Low margin/light intensity inadequate D2 Light array status Off Target not present Red Target present Red flashing System D3 Out1 Off Output 1 inactive Green Output 1 active D4 Out2 Off Output 2 inactive Green Output 2 active D5 In1 Off Input 1 inactive Green Input 1 active D6 In2 Off Input 2 inactive Green Input 2 active D7 Power Off Power off Green Power on Table 5 - Controller Main PCB Potentiometer Adjustments Pot Description Direction Limit Value Pot 1 (1) (1) Potentiometer 1 is not used on the analog controller model.