MVME-5100工控機(jī)器人備件
請(qǐng)注意,項(xiàng)目的描述性名稱也可能會(huì)更改,因?yàn)樗鼈円词菑尿?qū)動(dòng)器中提取的,要么是人工重新構(gòu)建的(如果不可用)。還請(qǐng)注意,您的選擇可能包含已駐留在新驅(qū)動(dòng)器中的項(xiàng)目。它們?nèi)员3治催x中狀態(tài)。如果所有選定項(xiàng)目都位于新驅(qū)動(dòng)器中,菜單中的“更改驅(qū)動(dòng)器”命令將被禁用(灰色)。如果新驅(qū)動(dòng)器不包含某些要更改的項(xiàng)目,則不會(huì)進(jìn)行任何更改。在這種情況下,DriveWindow只會(huì)發(fā)出嘟嘟聲。更改項(xiàng)目的聯(lián)機(jī)狀態(tài)和鎖定狀態(tài)不變。另請(qǐng)參閱:通用趨勢(shì)設(shè)置設(shè)置監(jiān)視器監(jiān)視器和數(shù)據(jù)記錄器監(jiān)視器設(shè)置監(jiān)視器菜單監(jiān)視器設(shè)置上下文菜單將項(xiàng)目添加到項(xiàng)目集編輯菜單瀏覽樹窗格4.設(shè)置數(shù)據(jù)記錄器在進(jìn)行任何數(shù)據(jù)記錄器設(shè)置之前,您需要選擇數(shù)據(jù)記錄器而不是監(jiān)視器。此外,您必須選擇要更改或查看的數(shù)據(jù)記錄器設(shè)置。請(qǐng)注意,您不能使用DriveWindow更改本地DriveDA OPC服務(wù)器驅(qū)動(dòng)器(AC880系列)的數(shù)據(jù)記錄器設(shè)置。您只能控制ACS880系列驅(qū)動(dòng)器的數(shù)據(jù)記錄器并更改常見設(shè)置。盡管驅(qū)動(dòng)器中可能有更多通道,但也只能顯示六個(gè)通道。趨勢(shì)6-38驅(qū)動(dòng)窗口2除了監(jiān)視器和數(shù)據(jù)記錄器的常見設(shè)置(x軸長度、y軸最小值和最大值、y軸自適應(yīng)、通道縮放)外,數(shù)據(jù)記錄器具有以下設(shè)置:?數(shù)據(jù)記錄器狀態(tài)顯示在線/離線?間隔?預(yù)觸發(fā)時(shí)間(以毫秒為單位)?觸發(fā)條件?觸發(fā)變量?觸發(fā)級(jí)別?觸發(fā)滯后?要記錄的變量注意,任何時(shí)候只能更改數(shù)據(jù)記錄器狀態(tài)的在線/離線顯示。除非數(shù)據(jù)記錄器圖形已清除,且驅(qū)動(dòng)器中的數(shù)據(jù)記錄器未運(yùn)行,否則其他任何數(shù)據(jù)都無法更改。通用設(shè)置可以隨時(shí)更改。除常見設(shè)置和數(shù)據(jù)記錄器狀態(tài)刷新外,所有設(shè)置實(shí)際上都保存在驅(qū)動(dòng)器中。它們也是項(xiàng)目,可以像任何其他項(xiàng)目一樣瀏覽、查看和更改。但是,如果要使用DriveWindow中的高級(jí)數(shù)據(jù)記錄器處理功能,則不應(yīng)使用原始項(xiàng)。4.1.1選擇數(shù)據(jù)記錄器而不是監(jiān)視器您可以通過單擊趨勢(shì)設(shè)置窗格中的數(shù)據(jù)記錄器選項(xiàng)卡來選擇數(shù)據(jù)記錄器,而不是監(jiān)視器。4.1.2選擇數(shù)據(jù)記錄器如果驅(qū)動(dòng)器只有一個(gè)數(shù)據(jù)記錄器,只需在瀏覽樹窗格中選擇驅(qū)動(dòng)器即可。請(qǐng)注意,要選擇驅(qū)動(dòng)器,不必選擇其根,選擇其任何子分支即可。如果驅(qū)動(dòng)器有兩個(gè)數(shù)據(jù)記錄器,則也必須選擇當(dāng)前驅(qū)動(dòng)器數(shù)據(jù)記錄器。從瀏覽樹窗格中選擇驅(qū)動(dòng)器后,可以使用瀏覽樹窗格或通過在數(shù)據(jù)記錄器菜單或數(shù)據(jù)記錄器顯示的上下文菜單中切換數(shù)據(jù)記錄器2開關(guān)來進(jìn)行選擇。或或趨勢(shì)驅(qū)動(dòng)窗口2 6-39如果驅(qū)動(dòng)器有兩個(gè)以上的數(shù)據(jù)記錄器,則選擇驅(qū)動(dòng)器數(shù)據(jù)記錄器的方式與選擇兩個(gè)數(shù)據(jù)記錄器的方法相同。但是,菜單顯示的是下一個(gè)數(shù)據(jù)記錄器,而不是數(shù)據(jù)記錄器2。單擊下一數(shù)據(jù)記錄器會(huì)將驅(qū)動(dòng)器數(shù)據(jù)記錄器選擇移至下一數(shù)據(jù)記錄儀。請(qǐng)注意,最后一個(gè)數(shù)據(jù)記錄器的下一個(gè)是第一個(gè)數(shù)據(jù)記錄器。
Note that the descriptive names of the items may also change because they are either fetched from the drive or, if not available, artificially re-constructed. Note also that your selection can contain items, which already reside in the new drive. They remain as if they were unselected. If all selected items reside in the new drive, the Change Drive command in the menus is disabled (grayed). If the new drive does not contain some of the items to be changed, no changes are made. DriveWindow just beeps in such a case. The on-line and locking states of the changed items do not change. See Also: Common Trend Settings Setting Monitor Monitor and Dataloggers Monitor Settings Monitor Menu Context Menu of Monitor Settings Adding Items to an Item Set Edit Menu Browse Tree Pane 4. Setting Datalogger Before you can do any datalogger settings, you need to have dataloggers selected instead of the monitor. Also, you have to select the datalogger, settings of which you want to change or view. Note that you cannot use DriveWindow to change datalogger settings of native DriveDA OPC server drives (AC880 family). You are only able to control dataloggers of ACS880 family of drives and change common settings. Also only six channels can be shown although there may be more channels in the drive. Trends 6-38 DriveWindow 2 In addition to the common settings (x-axis length, y-axis minimum and maximum, adaptation of y-axis, scaling of channels) for monitor and dataloggers, a datalogger has the following settings: ? Datalogger status display on-line/off-line ? Interval ? Pre-triggering time in milliseconds ? Triggering conditions ? Triggering variable ? Triggering level ? Triggering hysteresis ? Variables to be logged Note that only the datalogger status display on-line/off-line can be changed at any time. None of the others can be changed unless the datalogger graph is cleared, and the datalogger in the drive is not running. The common settings can be changed any time. Except the common settings and the datalogger status refresh, all settings are actually kept in the drive. They are also items, which can be browsed, viewed and changed as any other items. However, if you are going to use the upper level datalogger handling functionality in DriveWindow, you should not use the raw items. 4.1.1 Selecting dataloggers instead of the monitor You select dataloggers instead of the monitor by clicking the Datalogger tab in the trend settings pane. 4.1.2 Selecting the datalogger If the drive has only one datalogger, it is enough just to select the drive in the browse tree pane. Note that to select a drive, it is not necessary to select its root, selection of any of its sub-branches will do. If the drive has two dataloggers, the current drive datalogger has to be selected, too. Selection can be done either using the browse tree pane or by toggling the Datalogger 2 toggle in the Datalogger menu or in the context menu of Datalogger Display after the drive has been selected from the browse tree pane. or or Trends DriveWindow 2 6-39 If the drive has more than two dataloggers, the drive datalogger is selected the similar way as in the case of two dataloggers. However, a menu shows Next Datalogger instead of Datalogger 2. Clicking of Next Datalogger moves the drive datalogger selection to the next datalogger. Note that the next datalogger of the last one is the first datalogger.