中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗(yàn),請(qǐng)點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪問(wèn)瑞昌明盛自動(dòng)化設(shè)備有限公司網(wǎng)站!

圖片名

全國(guó)訂購(gòu)熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

MVME374-001機(jī)械設(shè)備卡件

MVME374-001機(jī)械設(shè)備卡件

MVME374-001機(jī)械設(shè)備卡件可以編輯所有配置并將其復(fù)制到新配置。您可以從“編輯”菜單或右鍵單擊“當(dāng)前配置”下拉列表時(shí)顯示的上下文菜單中選擇操作?;蜃⒁?,您也可以通過(guò)點(diǎn)擊Del鍵來(lái)刪除所選的當(dāng)前配置。配置可以包含以下連接到SAP/http設(shè)備的方法的任意組合:?固定IP列表(不在默認(rèn)配置中)。?附近的設(shè)備,即本地以太網(wǎng)段中的所有設(shè)備(通過(guò)廣播搜索)。?Intranet設(shè)備,即與PC位于同一子網(wǎng)...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

MVME374-001機(jī)械設(shè)備卡件

    MVME374-001機(jī)械設(shè)備卡件

    可以編輯所有配置并將其復(fù)制到新配置。您可以從“編輯”菜單或右鍵單擊“當(dāng)前配置”下拉列表時(shí)顯示的上下文菜單中選擇操作?;蜃⒁猓部梢酝ㄟ^(guò)點(diǎn)擊Del鍵來(lái)刪除所選的當(dāng)前配置。配置可以包含以下連接到SAP/http設(shè)備的方法的任意組合:?固定IP列表(不在默認(rèn)配置中)。?附近的設(shè)備,即本地以太網(wǎng)段中的所有設(shè)備(通過(guò)廣播搜索)。?Intranet設(shè)備,即與PC位于同一子網(wǎng)中的所有設(shè)備(通過(guò)廣播搜索)。此外,您可以配置DriveDA嘗試用于RS-485通信的COM端口的使用。在實(shí)踐中,您只使用只有固定IP的配置。使用廣播的其他方法可以用于具有SAP/http設(shè)備的訓(xùn)練或其他條件,其IP地址經(jīng)常改變。OPC服務(wù)器驅(qū)動(dòng)窗口2 7-49 8.1.4測(cè)試配置要測(cè)試選定的當(dāng)前配置,請(qǐng)單擊測(cè)試按鈕。如果按鈕呈灰色,則可能安裝了舊版本的DriveDA(實(shí)際上是其通信模塊)。將顯示一個(gè)對(duì)話框,其中包含所選當(dāng)前配置找到的COM端口和SAP/http設(shè)備的列表。請(qǐng)注意,測(cè)試不會(huì)檢查NETA-21的RS-485網(wǎng)絡(luò)中是否有驅(qū)動(dòng)器。因此,盡管找到了SAP/http設(shè)備,但當(dāng)DriveWindow連接到DriveDA時(shí),可能找不到驅(qū)動(dòng)器。還要注意,即使其面板網(wǎng)關(guān)被禁用,也可以找到NETA-21設(shè)備。但是,當(dāng)DriveWindow連接到DriveDA時(shí),找不到驅(qū)動(dòng)器。如果測(cè)試未找到任何COM端口或SAP/http設(shè)備,將顯示消息框而不是對(duì)話框。OPC服務(wù)器7-50 DriveWindow 2 8.1.5保存更改要保存對(duì)SAP/http配置所做的任何更改,請(qǐng)單擊SAP/http配置對(duì)話框中的確定按鈕。8.1.6編輯配置通常,您很少編輯默認(rèn)配置。要編輯配置,請(qǐng)首先將其選擇為“當(dāng)前配置”,然后從“編輯”或上下文菜單中選擇“屬性”?;騉PC服務(wù)器驅(qū)動(dòng)窗口2 7-51顯示配置設(shè)置對(duì)話框。通常使用默認(rèn)值,即默認(rèn)配置中定義的值。一個(gè)例外是SAP/http通信可能需要啟用,因?yàn)樗赡茉谀J(rèn)情況下被禁用。并非所有設(shè)置都顯示在對(duì)話框中。FixedIP中列出的每個(gè)固定IP的設(shè)置都顯示在單獨(dú)的對(duì)話框中。OPC服務(wù)器7-52 DriveWindow 2 8.1.7固定IP設(shè)置要編輯固定IP的設(shè)置,請(qǐng)?jiān)谂渲迷O(shè)置對(duì)話框的固定IP列表中單擊該設(shè)置,然后從編輯菜單中選擇屬性命令,或在固定IP列表中右鍵單擊該設(shè)置并從顯示的上下文菜單中選擇“屬性”命令?;蝻@示配置的固定IP設(shè)置對(duì)話框。OPC服務(wù)器驅(qū)動(dòng)窗口2 7-53 8.1.8添加和刪除固定IP可在“編輯”菜單中找到用于添加或刪除固定IP的命令

    All configurations can be edited and copied to a new. You can select to operation either from the Edit menu or the context menu, which is shown when you right click Current configuration drop down list. or Note that you can delete the selected Current configuration also by hitting the Del key. A configuration can contain any combination of the following methods of connecting to SAP/http devices: ? A list of fixed IPs (not in the Default configuration). ? Devices near, i.e., all devices in the local Ethernet segment (searched by broadcast). ? Intranet devices, i.e., all devices in the same subnet as the PC (searched by broadcast). In Addition you can configure the use of COM-ports that DriveDA tries to use for RS-485 communication. In practise you use only configurations that have just fixed IPs. The other methods using broadcast could be used in training or other conditions having SAP/http devices, IP addresses of which change frequently. OPC Server DriveWindow 2 7-49 8.1.4 Testing a Configuration To test the selected Current configuration, click the Test button. If the button is grayed, you probably have an old version of DriveDA (actually its communication module) installed. A dialog box containing a list of COM-ports and SAP/http devices found by the selected Current configuration is displayed. Note that the test does not check that there are drives in the RS-485 networks of a NETA-21. So it is possible that although there are SAP/http devices found, no drive is found when DriveWindow is connected to DriveDA. Note also that NETA-21 devices are found even if its panel gateway is disabled. However, no drive can be found when DriveWindow connects to DriveDA. If the test does not find any COM-ports or SAP/http devices, instead of a dialog box a message box is shown. OPC Server 7-50 DriveWindow 2 8.1.5 Saving Changes To save any changes made into the SAP/http configurations, click the OK button in the SAP/http Configuration dialog box. 8.1.6 Editing a Configuration Typically, you seldom edit the Default configuration. To edit a configuration, first select it as the Current configuration and then select Properties from the Edit or context menu. or OPC Server DriveWindow 2 7-51 The configuration Settings dialog box is displayed. Typically default values, i.e., values defined in the Default configuration, are used. An exception is that SAP/http Communication may require enabling because it may be disabled by default. Not all of the settings are shown in the dialog box. Settings for each fixed IP listed in FixedIPs are presented in a separate dialog box. OPC Server 7-52 DriveWindow 2 8.1.7 Settings for Fixed IPs To edit settings for a Fixed IP, either select it by clicking it in the Fixed IPs list in the dialog box for Settings of a configuration and then select the Properties command from the Edit menu, or right click it in the Fixed IPs list and select Properties command from the context menu displayed. or The Fixed IP Settings dialog box for the configuration is displayed. OPC Server DriveWindow 2 7-53 8.1.8 Adding and Deleting Fixed IPs Commands for adding and deleting a Fixed IP can be found in the Edit menu

    ETT-VGA UNIOP.jpg

    23.jpg

    18.jpg

    11.jpg

    微信圖片_20211117105502.png



    品牌:  Motorola 

    型號(hào):MVME374-001 

    產(chǎn)地:美國(guó)

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨



圖片名 客服

在線客服 客服一號(hào)