MVME2600控制卡件
12、18或30添加到目錄號末尾(以毫米為單位)。2在目錄號末尾添加12或18(以毫米計)。所需線組和附件*其他可用連接選項,請參閱http://ab.rockwellautomation.com/Sensors-Switches詳細訂購信息。ac140MP電機保護斷路器基本短路和熱保護概述公告140MP電機防護斷路器(MPCB)或電機保護開關(guān)設(shè)備(MPSD)提供高達32A的磁短路和熱過載保護。它們與Allen-Bradley?Bulletin 100-C和100-K接觸器一起進行測試,以創(chuàng)建雙組件電機起動器。這些被UL列為手動電機控制器(具有適用于電機斷開和適用于成組安裝的可選批準(zhǔn))。成組電機安裝消除了對每個電機電路單獨分支短路保護裝置的需求,減少了面板空間、安裝和布線時間以及成本?!敖M”只有一個分支電路保護裝置(BCPD)。這些設(shè)備符合IEC 60947-4-1規(guī)定的電機保護開關(guān)設(shè)備(MPSD)和IEC 60947-2規(guī)定的電路燒杯的要求,適用于北美以外的應(yīng)用。這些設(shè)備可提供以下功能。?電機分支電路的斷開連接?短路保護(磁保護)?過載保護(熱保護)?手動開關(guān)(電機控制裝置)功能和優(yōu)點?過載保護–跳閘等級10A?相位損失靈敏度?斷開功能?適用于三相和單相應(yīng)用?UL組電機和IEC 1型和2型?CE,cULus、CCC、KC、EAC認證?400V時的中斷額定值:高達100 kA磁短路和熱過載保護,高達32,并與Allen-Bradley Bulletin 100接觸器一起測試額定工作電流(Ie)[A]電機電流調(diào)整范圍[A]標(biāo)稱磁跳閘電流[A]最大短路電流[kA]最大三相Hp額定值*最大kW,3相羅克韋爾自動化公司保留所有權(quán)利。在美國印刷的Allen-Bradley和Expanding human possibility是羅克韋爾自動化股份有限公司的商標(biāo)。不屬于羅克韋爾自動化的商標(biāo)是其各自公司的財產(chǎn)。
還可提供全系列兼容附件,包括:?饋線接線板和緊湊型母線?常開和常閉前部和側(cè)面安裝的輔助觸點?并聯(lián)跳閘和欠壓跳閘輔助觸點?門耦合手柄?IP65外殼(UL/CSA類型12)有關(guān)附件和規(guī)格的更多詳細信息,請參閱ab.com上的技術(shù)數(shù)據(jù)*所示馬力/kW額定值僅供參考。MPCB/MPSD的最終選擇取決于實際電機滿載電流。800T/H防爆接觸塊一種適用于I類2區(qū)危險場所的重型解決方案公告800TC-XAF防爆接觸塊是適用于I級2區(qū)環(huán)境的堅固解決方案,尤其適用于不需要典型簧片開關(guān)解決方案的急停和高振動應(yīng)用。緊急停止應(yīng)用–簧片開關(guān)的磁性操作設(shè)計防止其與緊急停止裝置一起使用。相比之下,800TC-XAF防爆接觸塊具有符合全球緊急停止標(biāo)準(zhǔn)所需的正開常閉觸點。此外,該設(shè)計允許接觸塊堆疊,這增加了應(yīng)用靈活性,并適應(yīng)照明急停裝置的安全電路。高振動應(yīng)用–簧片開關(guān)密封在玻璃外殼中,玻璃外殼易碎,容易受到與高振動相關(guān)的應(yīng)力損壞。800TC-XAF防爆接觸塊的主體由極其耐用的熱塑性樹脂模制而成,因此接觸塊組件將在最惡劣的應(yīng)用中保持I類Div.2的完整性。除了I類Div.2應(yīng)用中可能存在的易燃氣體、液體或蒸汽的爆炸性外,這些材料也可能具有高度腐蝕性。考慮到這一點,我們對800TC-XAF防爆接觸塊中使用的部件的材料選擇給予了謹慎的注意,以幫助確保在最苛刻的環(huán)境中安全可靠地運行:?玻璃填充聚酯接觸塊主體?不銹鋼五金件,包括端子螺釘/夾具和安裝螺釘?陶瓷柱塞?帶純銀觸點尖端的分叉扳手功能和優(yōu)點?適用于I類Div.2環(huán)境(A、B、C和D組)的可靠UL 1203認證解決方案?Rutches–按壓測試指示燈危險場所應(yīng)用的最新接觸開關(guān)。出版物800T-PP010A-EN-P–4月
12. 18 or 30 is added to the end of the catalog number in millimeters. 2 Add 12 or 18 (in millimeters) at the end of the catalog number. Required line groups and accessories * Other available connection options, see http://ab.rockwellautomation.com/Sensors-Switches Detailed ordering information. Ac140MP Motor Protection Circuit Breaker Basic Short Circuit and Thermal Protection Overview Bulletin 140MP Motor Protection Circuit Breaker (MPCB) or Motor Protection Switchgear (MPSD) provides magnetic short circuit and thermal overload protection up to 32A. They are associated with Allen Bradley ? Bulletin 100-C and 100-K contactors are tested together to create a dual component motor starter. These are UL listed as manual motor controllers (with optional approvals for motor disconnection and for group installation). Group motor installation eliminates the need for separate branch short circuit protection devices for each motor circuit, reducing panel space, installation and wiring time and cost. The "group" has only one branch circuit protection device (BCPD). These devices meet the requirements of motor protection switchgear (MPSD) specified in IEC 60947-4-1 and circuit beakers specified in IEC 60947-2, and are suitable for applications outside North America. These devices provide the following functions. ? Disconnection of motor branch circuit ? Short circuit protection (magnetic protection) ? Overload protection (thermal protection) ? Functions and advantages of manual switch (motor control device) ? Overload protection – tripping level 10A ? Phase loss sensitivity ? Disconnection function ? Suitable for three-phase and single-phase applications ? UL group motors and IEC type 1 and 2 ? CE, cULus, CCC, KC, EAC certification ? Interruption rating at 400V: up to 100 kA magnetic short circuit and thermal overload protection, Up to 32, and test the rated working current (Ie) [A] motor current adjustment range [A] nominal magnetic trip current [A] maximum short circuit current [kA] maximum three-phase Hp rating * maximum kW with Allen Bradley Bullet 100 contactor, 3-phase Rockwell Automation reserves all rights. Allen Bradley and Expanding human probability printed in the United States are trademarks of Rockwell Automation Co., Ltd. Trademarks that are not part of Rockwell Automation are the property of their respective companies.
A full range of compatible accessories are also available, including: ? Feeder terminal blocks and compact buses ? Normally open and normally closed front and side mounted auxiliary contacts ? Shunt trip and undervoltage trip auxiliary contacts ? Door coupling handles ? IP65 enclosure (UL/CSA type 12) For more details on accessories and specifications, please refer to the technical data on ab.com * Horsepower/kW ratings shown are for reference only. The final selection of MPCB/MPSD depends on the actual motor full load current. 800T/H Explosion proof Contact Block is a heavy-duty solution for Class I, Zone 2 hazardous locations Announcement 800TC-XAF Explosion proof Contact Block is a robust solution for Class I, Zone 2 environments, especially for emergency stop and high vibration applications that do not require typical reed switch solutions. Emergency Stop Applications – The magnetic operation of the reed switch is designed to prevent it from being used with the emergency stop device. In contrast, the 800TC-XAF explosion-proof contact block has positive open normally closed contacts that meet the global emergency stop standards. In addition, the design allows contact block stacking, which increases application flexibility and adapts to the safety circuit of the lighting emergency stop device. High vibration applications – Reed switches are enclosed in a glass enclosure that is fragile and vulnerable to stress damage associated with high vibration. The body of 800TC-XAF explosion-proof contact block is molded from extremely durable thermoplastic resin, so the contact block assembly will maintain the integrity of Class I Div.2 in the worst application. In addition to the explosive nature of flammable gases, liquids, or vapors that may be present in Class I Div.2 applications, these materials may also be highly corrosive. With this in mind, we pay careful attention to the material selection of the components used in the 800TC-XAF explosion-proof contact block to help ensure safe and reliable operation in the most demanding environment: ? glass filled polyester contact block body ? stainless steel hardware, Includes terminal screws/clamps and mounting screws ? Ceramic plunger ? Fork wrench features and benefits with sterling silver contact tips ? Reliable UL 1203 certified solution for Class I Div.2 environments (Groups A, B, C, and D) ? Rutches – Push to test the latest contact switches for use in hazardous locations. Publication 800T-PP010A-EN-P – April