MVME197LE工控機(jī)器人備件
遵守電氣安全預(yù)防措施。c) 徹底檢查型材和部件有無(wú)機(jī)械損壞。d) 斷開(kāi)端子Z1-Z2處的輪廓線。e)將輪廓線的導(dǎo)線連接到歐姆表的輸入端?,F(xiàn)在,一個(gè)人應(yīng)該用一只手按壓條帶上的每個(gè)點(diǎn)。電阻測(cè)量值應(yīng)為6K? +/- 未按下型材時(shí)為10%,按下型材時(shí)不超過(guò)1K。如果這些檢查發(fā)現(xiàn)任何問(wèn)題,則在糾正之前不得使用機(jī)器。將檢查和測(cè)試記錄在書面日志中。7 6.0維護(hù)和服務(wù)6.1故障查找指南癥狀可能原因檢查剖面中的“黃色”LED開(kāi)路或Z1-Z2端子是否牢固。照明。連接接線。電纜斷裂剖面圖損壞。即使電源故障,LED也不會(huì)點(diǎn)亮。電壓選擇開(kāi)關(guān)設(shè)置正確。輪廓被按下。電源保險(xiǎn)絲。存在電源電壓。除非復(fù)位失敗,否則LED不會(huì)點(diǎn)亮。如果使用接觸器監(jiān)控,請(qǐng)檢查是否按下Profile,然后每個(gè)接觸器是否正常工作。停止“紅色”LED MC-MC端子是安全的。照明。鏈接到位或重置按鈕功能正常。裝置似乎工作保險(xiǎn)絲熔斷。輸出保險(xiǎn)絲。正確,但沒(méi)有損壞或不正確的接線。所有接線是否損壞。輸出Safedge上的故障導(dǎo)致任何內(nèi)部繼電器移動(dòng)。故障安全輸出REPLACE CONTROLLER。如果外部連接不正確,機(jī)器不會(huì)停止所有到接觸器的接線都有錯(cuò)誤。
輪廓已按下。運(yùn)行“綠色”LED熄滅。如果按下“不允許使用機(jī)器配置文件”,機(jī)器不會(huì)停止。更換控制器。運(yùn)行“綠色”LED保持亮起。6.2維護(hù)在嘗試任何維護(hù)工作之前,應(yīng)完整閱讀本節(jié)內(nèi)容。請(qǐng)注意歐盟指令89/655/EEC(作為1992年工作設(shè)備的提供和使用條例在英國(guó)實(shí)施)下的計(jì)劃預(yù)防性維護(hù)條例。在維護(hù)操作期間,在使用Safedge系統(tǒng)之前,斷開(kāi)機(jī)器的原動(dòng)機(jī)。遵守電氣安全預(yù)防措施。19 3.2.2當(dāng)使用帶有密封唇的封閉蓋440F-A1302時(shí),必須將型材底部切割至12mm的長(zhǎng)度。必須小心進(jìn)行切割,以確保型材底部被完全修剪掉,留下齊平的表面。3.2.3陰影區(qū)域必須用砂紙粗糙3.2.4封閉蓋用4個(gè)密封圈模制,每個(gè)密封圈都有一個(gè)橡膠塞。安裝電阻器時(shí),保持插頭完好無(wú)損。進(jìn)行電纜連接時(shí),選擇所需的電纜出口,并用打孔器從索環(huán)上取下插頭。3.2.5將連接電纜穿過(guò)孔。12 8 3.2.6用其中一根針刺破每根銅線。按所示方向(向外楔入)將接頭的針觸點(diǎn)直接壓入銅線。3.2.7小心連接器的窄側(cè)(楔形)必須向外突出。3.2.8折回蓋的密封唇;a) 如圖所示,在封口蓋的陰影區(qū)域涂上粘合劑,然后粘貼到型材邊緣,加壓10秒以確保粘合。b)
Observe electrical safety precautions. c) Thoroughly inspect the profiles and components for mechanical damage. d) Disconnect the contour line at terminals Z1-Z2. e) Connect the lead of the contour line to the input of the ohmmeter. Now, one should press each point on the strip with one hand. The resistance measurement value shall be 6K ?+/- 10% when the profile is not pressed, and not more than 1K when the profile is pressed. If these checks reveal any problems, do not use the machine until it is corrected. Record inspections and tests in a written log. 7 6.0 Maintenance and service 6.1 Troubleshooting guide Possible causes of symptoms Check whether the "yellow" LED in the profile is open circuit or Z1-Z2 terminal is firm. Lighting. Connect the wiring. The cable fracture profile is damaged. The LED will not illuminate even if the power supply fails. The voltage selector switch is set correctly. The contour is pressed. Power fuse. Supply voltage is present. The LED will not illuminate unless reset fails. If the contactor monitoring is used, check whether the Profile is pressed, and then whether each contactor works normally. It is safe to stop the "red" LED MC-MC terminal. Lighting. Link in place or reset button functions normally. The unit appears to be working with a blown fuse. Output fuse. Correct, but no damaged or incorrect wiring. Whether all wiring is damaged. A fault on the output Safedge causes any internal relays to move. Fail safe output REPLACE CONTROLLER. If the external connection is incorrect, the machine will not stop all the wiring to the contactor has errors.
Contour pressed. The running "green" LED is off. If you press "Do not allow to use machine configuration file", the machine will not stop. Replace the controller. The operating "green" LED remains lit. 6.2 Maintenance Read this section completely before attempting any maintenance work. Please note the planned preventive maintenance regulations under EU Directive 89/655/EEC (implemented in the UK as a provision and use of work equipment regulation in 1992). During maintenance operations, disconnect the prime mover of the machine before using the Safedge system. Observe electrical safety precautions. 19 3.2.2 When using a closing cap 440F-A1302 with a sealing lip, the bottom of the profile must be cut to a length of 12 mm. Care must be taken in cutting to ensure that the bottom of the profile is completely trimmed off, leaving a flush surface. 3.2.3 The shaded area must be roughened with sandpaper 3.2.4 The closed cover shall be molded with 4 sealing rings, and each sealing ring shall have a rubber plug. Keep the plug intact when installing the resistor. For cable connection, select the required cable outlet and use a hole punch to remove the plug from the grommet. 3.2.5 Pass the connecting cable through the hole. 12 8 3.2.6 Puncture each copper wire with one of the needles. Press the pin contact of the connector directly into the copper wire in the direction shown (wedging outward). 3.2.7 Be careful that the narrow side (wedge) of the connector must protrude outward. 3.2.8 Return the sealing lip of the cover; a) As shown in the figure, apply adhesive to the shaded area of the closure cap, and then stick it to the edge of the profile. Press for 10 seconds to ensure adhesion. b)