停止“紅色”LED亮起。c) 安全觸點(diǎn)打開。d) 輔助觸點(diǎn)閉合。e) 接觸器斷電。4) 釋放配置文件a)停止“紅色”LED熄滅。b) 系統(tǒng)已返回到步驟1a。5) 如果在重置前按下配置文件,a)每次按下配置文件時(shí),停止“紅色”LED將點(diǎn)亮,但安全觸點(diǎn)不會(huì)通電。440F-C251P表面安裝440F-C2514D DIN導(dǎo)軌繼電器輸出:2 x獨(dú)立無電壓N/O安全觸點(diǎn)1 x無電壓N/C輔助觸點(diǎn)注意:輔助觸點(diǎn)不應(yīng)用于安全用途類別:AC-15;2A/250V直流-13;2A/30V DC安全輸入:安全曲線(開路電阻6K? ) 指示LED 1:綠色:運(yùn)行。LED 2:黃色:打開。LED 3:紅色:停止。內(nèi)部控制:交流電壓選擇器內(nèi)部保險(xiǎn)絲:2A安全保險(xiǎn)絲可更換(2個(gè))500mAT電源保險(xiǎn)絲可更換。環(huán)境溫度范圍-剖面-5°C至+55°C,不包括110N和01610N(0°C至55°C)濕度:+55°C.時(shí)相對(duì)濕度高達(dá)90%。振動(dòng):根據(jù)IEC 68-2-6進(jìn)行測(cè)試,頻率范圍10-55Hz,位移0.15mm,每軸10個(gè)周期,掃描速率,每分鐘1個(gè)八度,MC-MC接觸器監(jiān)控回路:N/C(常閉)接觸器回路最大導(dǎo)線尺寸:1 x 1 mm 2絞合,套管剝離1x2.5 mm 2絞合套管剝離5mm,1 x 1.5mm 2實(shí)心導(dǎo)線。8mm,1 x 4 mm 2實(shí)心導(dǎo)體端子:負(fù)端子螺釘+負(fù)端子螺釘M3.5,M2彈簧作用。自舉連接,墊圈端子板可單獨(dú)拆卸。安裝組:符合VDE 0110的C。材料:聚碳酸酯固定細(xì)節(jié):4 x M4孔35 mm DIN導(dǎo)軌外殼:D=75mm,H=130mm,W=130mm D=120mm,H=73mm,W=45.5mm,16路重量:650g 450g
其他:安全型材必須以6K終止? 電阻器。11 16 440F-E0110N 440F-E0110 s 440F-E0310S 440F-E1610N 440F-E1610 s致動(dòng)距離:6.4mm 6.6mm 8.0mm 7.8mm 9.4mm響應(yīng)距離:1.2mm 1.9mm 27.2mm 8.4mm 5.0mm?最大速度:100 mm/s?適合檢測(cè)手指控制單元不得安裝在危險(xiǎn)區(qū)內(nèi)。手動(dòng)復(fù)位或常規(guī)指示器觀察需要接近控制單元,因此必須能夠看到其運(yùn)行。控制單元可以安裝在電動(dòng)門的任何一側(cè),只要唯一的危險(xiǎn)是實(shí)際的門。在所有其他情況下,考慮到測(cè)試和維護(hù)的訪問要求,控制單元可以安裝在危險(xiǎn)區(qū)外任何方便的地方。3.3.2安裝440F-C251P(表面安裝)440F-C2514D(Din導(dǎo)軌安裝)35MM Din導(dǎo)軌安裝45.5 73 120 A1+Z2 MC 13 23 31 A2-Z1 MC 14 24 32 115mm 130mm 115mm 4 x M4固定孔Pg16/21 Pg16/21 75mm 4.6復(fù)位端子MC-MC這些端子用于多種不同功能(表面安裝提供跳線,Din導(dǎo)軌提供無跳線)。在沒有跳線的情況下,端子可以連接到機(jī)器接觸器上的正向引導(dǎo)常閉輔助觸點(diǎn),以監(jiān)控雙通道控制系統(tǒng)中的接觸器。如果一個(gè)接觸器在其控制線圈斷電時(shí)未能隔離電源,則Safedge系統(tǒng)將不允許另一個(gè)接觸器通電,直到故障得到糾正。如果不需要此功能,請(qǐng)?jiān)贒IN導(dǎo)軌裝置的這些端子之間安裝跳線。此端子也用于自動(dòng)/手動(dòng)復(fù)位。如果MC-MC端子未跨接或僅連接至接觸器常閉觸點(diǎn),則裝置處于自動(dòng)復(fù)位模式。在自動(dòng)復(fù)位模式下,僅通過移除驅(qū)動(dòng)力來實(shí)現(xiàn)輸出。在致動(dòng)器通電時(shí)(當(dāng)不存在驅(qū)動(dòng)力時(shí))也可以實(shí)現(xiàn)輸出。
The stop "red" LED lights up. c) Safety contacts open. d) The auxiliary contacts are closed. e) The contactor is de energized. 4) Release the profile a) Stop The "red" LED goes off. b) The system has returned to step 1a. 5) If the profile is pressed before reset, a) the stop "red" LED will illuminate each time the profile is pressed, but the safety contacts will not be energized. 440F-C251P surface mount 440F-C2514D DIN rail relay output: 2 x independent voltage free N/O safety contact 1 x voltage free N/C auxiliary contact Note: auxiliary contact shall not be used for safety purpose Category: AC-15; 2A/250V DC - 13; 2A/30V DC safety input: safety curve (open circuit resistance 6K ?) indicating LED 1: green: running. LED 2: yellow: on. LED 3: red: stop. Internal control: AC voltage selector Internal fuse: 2A safety fuse replaceable (2) 500mAT power fuse replaceable. Ambient temperature range - profile - 5 ° C to+55 ° C, excluding 110N and 01610N (0 ° C to 55 ° C) Humidity:+55 ° C The relative humidity is up to 90%. Vibration: tested according to IEC 68-2-6, with frequency range of 10-55Hz, displacement of 0.15 mm, 10 cycles per axle, scanning rate of 1 octave per minute, MC-MC contactor monitoring circuit: N/C (normally closed) contactor circuit, maximum conductor size: 1 x 1 mm 2 stranded, casing stripping 1x2.5 mm 2 stranded, casing stripping 5 mm, 1 x 1.5 mm 2 solid conductor. 8mm, 1 x 4 mm2 solid conductor terminal: negative terminal screw+negative terminal screw M3.5, M2 spring action. Bootstrap connection, gasket terminal board can be disassembled separately. Installation group: C according to VDE 0110. Material: polycarbonate fixing details: 4 x M4 hole 35 mm DIN rail housing: D=75mm, H=130mm, W=130mm D=120mm, H=73mm, W=45.5mm, 16 circuit weight: 650g 450g
Others: The safety profile must terminate the ? resistor with 6K. 11 16 440F-E0110N 440F-E0110 s 440F-E0310S 440F-E1610N 440F-E1610 s Actuation distance: 6.4mm 6.6mm 8.0mm 7.8mm 9.4mm Response distance: 1.2mm 1.9mm 27.2mm 8.4mm 5.0mm ? Maximum speed: 100 mm/s ? Suitable for finger detection Control unit shall not be installed in hazardous area. Manual reset or conventional indicator observation requires access to the control unit, so it must be possible to see its operation. The control unit can be installed on either side of the electric door, as long as the only danger is the actual door. In all other cases, considering the access requirements for testing and maintenance, the control unit can be installed at any convenient place outside the hazardous area. 3.3.2 Install 440F-C251P (surface mount) 440F-C2514D (Din rail mount) 35MM Din rail mount 45.5 73 120 A1+Z2 MC 13 31 A2-Z1 MC 14 24 32 115mm 130mm 115mm 4 x M4 fixing hole Pg16/21 Pg16/21 75mm 4.6 reset terminal MC-MC These terminals are used for a variety of different functions (surface mount provides jumper, Din rail provides no jumper). Without jumpers, the terminals can be connected to the positive pilot normally closed auxiliary contacts on the machine contactors to monitor the contactors in the dual channel control system. If a contactor fails to isolate power when its control coil is de energized, the Safedge system will not allow another contactor to be energized until the fault is corrected. If this function is not required, install jumpers between these terminals of the DIN rail unit. This terminal is also used for automatic/manual reset. If the MC-MC terminal is not jumpered or only connected to the normally closed contact of the contactor, the device is in automatic reset mode. In the automatic reset mode, the output is achieved only by removing the driving force. The output can also be achieved when the actuator is energized (when there is no driving force).