中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過低,為保證更佳的瀏覽體驗(yàn),請(qǐng)點(diǎn)擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動(dòng)化設(shè)備有限公司網(wǎng)站!

圖片名

全國(guó)訂購熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

MVME172-523A工控模塊

MVME172-523A工控模塊

MVME172-523A工控模塊如果必須作出特殊安排,則可隨時(shí)提供適合系統(tǒng)的24V DC商用裝置。輔助輸出這是作為狀態(tài)輸出提供的非安全輸出。它在使用PLC功能機(jī)器控制和硬接線安全電路作為PLC狀態(tài)輸入的系統(tǒng)中特別有用。其他用途包括保護(hù)方案中的診斷和/或驅(qū)動(dòng)狀態(tài)燈或警報(bào)。安全功能不得依賴于此輸出。電弧抑制建議所有感應(yīng)負(fù)載使用電弧抑制網(wǎng)絡(luò)或設(shè)備。對(duì)于安全電路,抑制器應(yīng)安裝在負(fù)載上,而不能安裝在觸點(diǎn)上。...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

MVME172-523A工控模塊

    MVME172-523A工控模塊

    如果必須作出特殊安排,則可隨時(shí)提供適合系統(tǒng)的24V DC商用裝置。輔助輸出這是作為狀態(tài)輸出提供的非安全輸出。它在使用PLC功能機(jī)器控制和硬接線安全電路作為PLC狀態(tài)輸入的系統(tǒng)中特別有用。其他用途包括保護(hù)方案中的診斷和/或驅(qū)動(dòng)狀態(tài)燈或警報(bào)。安全功能不得依賴于此輸出。電弧抑制建議所有感應(yīng)負(fù)載使用電弧抑制網(wǎng)絡(luò)或設(shè)備。對(duì)于安全電路,抑制器應(yīng)安裝在負(fù)載上,而不能安裝在觸點(diǎn)上。抑制器的類型和額定值將由電源和負(fù)載特性決定。注意,抑制器可以增加響應(yīng)時(shí)間,特別是直流線圈兩端的抑制器二極管,并且在測(cè)量響應(yīng)時(shí)間時(shí)應(yīng)安裝到位??刂茊卧踩敵鲭娫粗量刂茊卧獔?zhí)行力時(shí)間20ms響應(yīng)時(shí)間控制單元安全輸入電源至控制裝置重置執(zhí)行力時(shí)間20m s響應(yīng)時(shí)間24接觸器監(jiān)控接觸器監(jiān)控通過標(biāo)記為MC的兩個(gè)端子提供。它應(yīng)用于所有雙通道雙接觸器系統(tǒng)。


    如果其中一個(gè)接觸器未能隔離電源,則墊控制單元將鎖定并防止另一個(gè)接觸器重新通電,直到故障得到糾正。5.8最終傳感器墊布局考慮到這些因素后,現(xiàn)在可以檢查并最終確定傳感器墊布局。考慮機(jī)器響應(yīng)時(shí)間是否與初始計(jì)算有所不同。在可能的情況下,應(yīng)在檢測(cè)區(qū)的外側(cè)邊緣設(shè)置墊子和電線。這簡(jiǎn)化了安裝和更換(如果需要),并且所有布線都受到周邊裝飾的保護(hù)。5.9布線所有系統(tǒng)布線必須防止機(jī)械損壞,并適當(dāng)密封以適應(yīng)操作環(huán)境。提供防水對(duì)接接頭用于墊子到墊子的連接,并由邊緣鑲邊保護(hù)。如果需要在地板上布線,440F-T3230導(dǎo)線導(dǎo)管可以提供適當(dāng)?shù)谋Wo(hù)。其他電線線路應(yīng)使用導(dǎo)管或線槽??刂茊卧拿芊馔暾员仨毻ㄟ^使用尺寸正確且緊固的導(dǎo)管配件或電纜壓蓋保持在IP65。布線實(shí)踐必須符合EN 60204-1第14條的要求。注意:為了確保110/230V電源的隔離,輸入電源必須單獨(dú)布線,并通過用于輸出接線的單獨(dú)配件或壓蓋進(jìn)入控制單元。從控制單元到墊子的電線可以使用導(dǎo)管埋在地板中,或通過邊緣裝飾件。


    If special arrangements must be made, 24V DC commercial devices suitable for the system can be provided at any time. Auxiliary Output This is a non safe output provided as a status output. It is particularly useful in systems that use PLC function machine control and hardwired safety circuits as PLC status inputs. Other uses include diagnostics and/or driving status lights or alarms in the protection scheme. The safety function must not depend on this output. Arc suppression It is recommended that all inductive loads use an arc suppression network or device. For safety circuits, suppressors shall be mounted on the load, not on the contacts. The type and rating of suppressors will be determined by the power supply and load characteristics. Note that the suppressor can increase the response time, especially the suppressor diodes at both ends of the DC coil, and should be installed in place when measuring the response time. The time from the safe output power of the control unit to the execution force of the control unit is 20ms, and the response time is 20ms. The time from the safe input power of the control unit to the reset execution force of the control device is 20ms. The response time is 24. The contactor monitoring is provided through two terminals marked MC. It is applied to all dual channel and dual contactor systems.

    If one of the contactors fails to isolate the power supply, the pad control unit will lock and prevent the other contactor from re energizing until the fault is corrected. 5.8 After taking these factors into account, the final sensor pad layout can now be checked and finalized. Consider whether the machine response time is different from the initial calculation. Where possible, mats and wires shall be provided at the outer edge of the detection area. This simplifies installation and replacement, if required, and all wiring is protected by the perimeter trim. 5.9 Wiring All system wiring must be protected from mechanical damage and properly sealed to adapt to the operating environment. Waterproof butt joints shall be provided for the connection of mat to mat, and shall be protected by edge trimming. 440F-T3230 conductor conduit can provide proper protection if wiring is required on the floor. Conduit or trunking shall be used for other wire routes. The sealing integrity of the control unit must be maintained at IP65 by using conduit fittings or cable glands of correct size and fastening. The wiring practice must comply with the requirements of Clause 14 of EN 60204-1. Note: In order to ensure the isolation of 110/230V power supply, the input power supply must be wired separately and enter the control unit through separate fittings or glands for output wiring. The wires from the control unit to the mat can be buried in the floor using conduits or through edge trims.

    fa405aeea632aa6912154382925a28b_副本.jpg

    GE VMIVME-7698-345 350-017698-345 B.jpg

    A-B 81001-450-53R.jpg

    微信圖片_20211117105502.png



    品牌:  Motorola 

    型號(hào):MVME172-523A 

    產(chǎn)地:美國(guó)

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號(hào)