小心完全開槽,以便周邊裝飾件的任何彎曲都不會(huì)夾住電線。確保沒有可能損壞導(dǎo)線的銳邊或毛刺。圖25進(jìn)入電纜槽(周邊飾板底部)的墊線建議切口的飾板固定件詳圖440F-T3013撓性導(dǎo)管入口建議切口的鋁制內(nèi)角周邊飾板(與440F-T3510、440F-T3310和440F-T3210一起使用)440F-T3012鋁制外角周邊飾條(與440F-13510、440 F-T3310及440F-T3211一起使用)應(yīng)力釋放夾具撓性導(dǎo)管切口槽此處,在鋒利的邊緣上使用邊緣護(hù)環(huán)剝下8mm的電線并插入壓接筒。使用壓接工具上正確的空腔尺寸壓接。使用帶導(dǎo)流板的加熱槍加熱壓接接頭,直到管道收縮,粘合劑收縮并流動(dòng)。27 440F-T3210、440F-T3310和440F-T3510 440F-T3211和440F-T3411對(duì)于外部拐角裝飾件,使用440F-T3014。對(duì)于內(nèi)部拐角裝飾件使用440F-T3105,440F-T3310和440F-T3510使用帶撓性導(dǎo)管的應(yīng)力消除夾具M(jìn)AT 1 MAT 2 MAT 1 MAT 2 MAT3 MAT 1 MAT 2 45°45°MAT 3 MAT 4將所有裝飾件切割成45°,如圖所示。標(biāo)記地板上的邊緣裝飾件固定位置,使裝飾件與墊重疊。以裝飾件上的孔為導(dǎo)向,標(biāo)記并鉆孔地板(如果需要,安裝塞子)。清潔地板,并使用沉頭螺釘將墊子和邊緣裝飾件固定到位,以適應(yīng)應(yīng)用。安裝周邊裝飾件時(shí),確保裝飾件和地板之間或頂部和底部之間(取決于裝飾件類型)沒有任何電線被夾住或壓碎。
如果電線可能被夾住或拉動(dòng),應(yīng)在電線離開周邊裝飾的地方使用應(yīng)變消除夾。所有電線應(yīng)采用適當(dāng)?shù)膶?dǎo)管進(jìn)行保護(hù)。如果可能,電線/導(dǎo)管不應(yīng)穿過可能會(huì)絆倒的地板區(qū)域。如果無法避免這種情況,應(yīng)將電線/導(dǎo)管封裝在我們的《保護(hù)電線指南》440F-T3230中(參見第37頁的可用備件)。6.2控制單元的安裝和布線(也可參考第4節(jié)圖7、第5.3.7節(jié)和第5.7節(jié))控制單元應(yīng)按照供應(yīng)進(jìn)行安裝。除本手冊(cè)所述的程序或連接外,不得對(duì)其進(jìn)行修改或進(jìn)行任何其他程序或連接。通過小心敲擊(440F-C4000P)或鉆出(440F-C4 000S,440FC28013)要使用的電纜入口位置來準(zhǔn)備控制單元。輸入電源必須單獨(dú)布線,并通過與輸出接線所用電源的單獨(dú)入口進(jìn)入控制單元。將控制單元安裝在其計(jì)劃位置??刂茊卧俗拥乃薪泳€必須使用提供的導(dǎo)線類型或多股導(dǎo)管電纜/開關(guān)設(shè)備電纜/設(shè)備導(dǎo)線,導(dǎo)線為0.5-1.5mm2。電纜進(jìn)入控制單元(440F-C4000P、440F-C400S和440F-C28013)時(shí),必須使用防護(hù)等級(jí)為IP65的壓蓋或適配器。確保壓蓋或適配器的尺寸合適并完全擰緊。必須使用提供的絕緣針腳壓褶。這種電線和端子組合避免了因過度擰緊或振動(dòng)而導(dǎo)致的松股短路或開路的可能性。確保使用合適的棘輪型壓接工具。
Be careful to fully slot so that any bending of the surrounding trim will not trap the wire. Make sure there are no sharp edges or burrs that could damage the wires. Figure 25 Detail of trim panel fastener with recommended notch for pad wire entering cable tray (bottom of peripheral trim panel) 440F-T3013 Aluminum inner corner peripheral trim panel with recommended notch for flexible conduit entrance (used with 440F-T3510, 440F-T3310 and 440F-T3210) 440F-T3012 Aluminum outer corner peripheral trim strip (used with 440F-13510, 440 F-T3310 and 440F-T3211) Stress release fixture Flexible conduit notch here, Peel off 8mm wires on sharp edges with edge protectors and insert the crimping cartridge. Crimp with the correct cavity size on the crimping tool. Use a heat gun with a deflector to heat the crimp joint until the pipe shrinks and the adhesive shrinks and flows. 27 440F-T3210, 440F-T3310 and 440F-T3510 440F-T3211 and 440F-T3411 For exterior corner trim, use 440F-T3014. For the interior corner trim, use 440F-T3105440F-T3310 and 440F-T3510 to cut all the trims to 45 ° using the stress relief fixture MAT 1 MAT 2 MAT 1 MAT 2 MAT3 MAT 1 MAT 2 45 ° 45 ° MAT 3 MAT 4 with flexible conduit, as shown in the figure. Mark the fixing position of the edge trim on the floor so that the trim overlaps the pad. Using the holes in the trim as a guide, mark and drill the floor (install plugs if necessary). Clean the floor and fix the mat and edge trim in place with countersunk screws to suit the application. When installing the perimeter trim, ensure that no wires are trapped or crushed between the trim and the floor or between the top and bottom (depending on the trim type).
If the wire may be pinched or pulled, strain relief clips should be used where the wire leaves the perimeter trim. All wires shall be protected by suitable conduits. Where possible, wires/conduits should not pass through floor areas where tripping may occur. If this cannot be avoided, the wire/conduit should be enclosed in our Guide to Protecting Wires 440F-T3230 (see available spare parts on page 37). 6.2 Installation and wiring of the control unit (also refer to Section 4, Figure 7, Section 5.3.7 and Section 5.7) The control unit shall be installed according to the supply. Except for the procedures or connections described in this manual, they shall not be modified or any other procedures or connections shall be made. Prepare the control unit by carefully tapping (440F-C4000P) or drilling out (440F-C4 000S, 440FC28013) the cable entry location to be used. The input power supply must be wired separately and enter the control unit through a separate entrance to the power supply used for output wiring. Install the control unit in its planned position. All wiring of control unit terminals must use the provided conductor type or multi strand conduit cable/switchgear cable/equipment conductor, with the conductor of 0.5-1.5mm2. When the cable enters the control unit (440F-C4000P, 440F-C400S and 440F-C28013), a gland or adapter with IP65 protection must be used. Ensure that the gland or adapter is properly sized and fully tightened. The insulation pins provided must be crimped. This wire and terminal combination avoids the possibility of loose strand short circuit or open circuit caused by excessive tightening or vibration. Make sure to use a suitable ratchet type crimping tool.