中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過低,為保證更佳的瀏覽體驗,請點擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設(shè)備有限公司網(wǎng)站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

MVME172-343模塊備件

MVME172-343模塊備件

MVME172-343模塊備件注意:如果接觸器卡在ON位置,則當(dāng)墊處于ON位置時,電機(jī)不會停止。圖16顯示了兩個接觸器和接觸器監(jiān)控(雙通道)440F-4000P和440F-C4000S的應(yīng)用連接圖示例。電路狀態(tài)-電源打開-傳感器墊上不存在-復(fù)位按鈕已操作(如果處于手動復(fù)位模式)-機(jī)器啟動電路已啟用。注意:如果任何一個接觸器卡在ON(接通)位置,則當(dāng)墊放在上面時,電機(jī)將停止,并檢測到故障。M K1...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

MVME172-343模塊備件

    MVME172-343模塊備件

    注意:如果接觸器卡在ON位置,則當(dāng)墊處于ON位置時,電機(jī)不會停止。圖16顯示了兩個接觸器和接觸器監(jiān)控(雙通道)440F-4000P和440F-C4000S的應(yīng)用連接圖示例。電路狀態(tài)-電源打開-傳感器墊上不存在-復(fù)位按鈕已操作(如果處于手動復(fù)位模式)-機(jī)器啟動電路已啟用。注意:如果任何一個接觸器卡在ON(接通)位置,則當(dāng)墊放在上面時,電機(jī)將停止,并檢測到故障。M K1 K2 24VDC,電源L1 L2 L3輔助輸出輔助輸入K1(AUX)K2(au)啟動瞬時按鈕停止瞬時按鈕熔斷器電機(jī)保護(hù),例如熱斷路器12 3 4+VE 31 13 23 MC MC 32 14 24控制單元K1 K2-VE正向引導(dǎo)接觸器輔助觸點L N110VAC,230VAC電源(備用電源連接)白色-白色-黑色-黑色傳感器墊內(nèi)部傳感器墊板N/O PB R IND M K1 24VDC,電源L1 L2 L3輔助輸出輔助輸入K1(輔助)啟動瞬時按鈕停止瞬時按鈕保險絲電機(jī)保護(hù),例如。熱斷路器12 3 4 MC MC+VE控制單元K1–VE白-白-黑-黑傳感器墊內(nèi)部傳感器墊板L N鏈路31 13 23 N/O PB R IND 32 14 24 110VAC,230VAC電源(備用電源連接)22圖17顯示單接觸器(單通道)440F-C4000D應(yīng)用的連接圖示例。電路狀態(tài)-電源打開-傳感器墊上不存在-復(fù)位按鈕已操作(如果處于手動復(fù)位模式)-機(jī)器啟動電路已啟用。注意:如果接觸器卡在ON位置,則當(dāng)墊處于ON位置時,電機(jī)不會停止。圖18顯示了兩個接觸器和接觸器監(jiān)控(雙通道)440F-C4000D應(yīng)用的示例連接圖。


    電路狀態(tài)-電源打開-傳感器墊上不存在-復(fù)位按鈕已操作(如果處于手動復(fù)位模式)-機(jī)器啟動電路已啟用。注意:如果任何一個接觸器卡在ON(接通)位置,則電機(jī)將在墊放置時停止,并檢測到故障。M K1 K2 24VDC,電源L1 L2 L3輔助輸出輔助輸入K1(AUX)K2(auux)啟動瞬時按鈕停止瞬時按鈕熔斷器電機(jī)保護(hù),例如熱斷路器12 3 4+31 MC MC 13 23 32 14 24控制單元K1 K2-正導(dǎo)接觸器輔助觸點A1 A2白-白-黑-黑-風(fēng)傳感器墊內(nèi)部傳感器墊板Y2 Y4 Y6復(fù)位IND Y1 Y3 Y5 110VAC,230VAC電源(備用電源連接)M K1 24VDC,電源L1 L2 L3輔助輸出輔助輸入K1(輔助)啟動瞬時按鈕停止瞬時按鈕熔斷器電機(jī)保護(hù),例如熱斷路器12 3 4 MC+控制單元K1–白-白-黑-黑傳感器墊內(nèi)部傳感器墊A1 A2鏈接31 13 23 Y2 Y4 Y6重置IND 32 14 24 Y1 Y3 Y5 MC 110VAC,230VAC電源(備用電源連接)23安全相關(guān)控制系統(tǒng)設(shè)計完成后,確保5.4.1中假設(shè)的響應(yīng)時間保持有效。如果值發(fā)生變化,則需要重復(fù)安全距離計算。接下來考慮重置選項。在正常條件和故障條件下,應(yīng)仔細(xì)考慮所選重置方案的后果,以防意外啟動等造成的危險。下面給出了墊子系統(tǒng)兩種模式的時序圖。圖19手動復(fù)位模式圖20自動復(fù)位模式驅(qū)動、復(fù)位和輸出之間的關(guān)系。啟動和輸出手動復(fù)位模式之間的關(guān)系可通過控制單元上的按鈕或遠(yuǎn)程按鈕或機(jī)器安全相關(guān)控制系統(tǒng)內(nèi)的無電壓觸點實現(xiàn)復(fù)位。系統(tǒng)的輸出將保持關(guān)閉,直到通電后復(fù)位,并且在存在其他通電聯(lián)鎖(啟動聯(lián)鎖)的復(fù)雜系統(tǒng)中可能需要主/從復(fù)位電路。自動復(fù)位模式當(dāng)在自動復(fù)位模式下使用時,機(jī)器的控制系統(tǒng)將需要一個單獨的復(fù)位功能,以防止機(jī)器在離開墊子或臨時電源故障或下降后啟動。


    Note: If the contactor is stuck in the ON position, the motor will not stop when the pad is in the ON position. Figure 16 shows the application connection diagram example of two contactors and contactor monitoring (dual channel) 440F-4000P and 440F-C4000S. Circuit status - power on - not present on sensor pad - reset button operated (if in manual reset mode) - machine start circuit enabled. Note: If any contactor is stuck in the ON position, the motor will stop and a fault will be detected when the pad is placed on it. M K1 K2 24VDC, power supply L1 L2 L3 auxiliary output auxiliary input K1 (AUX) K2 (au) start instantaneous button stop instantaneous button fuse motor protection, such as thermal circuit breaker 12 3 4+VE 31 13 23 MC MC 32 14 24 control unit K1 K2-VE forward guiding contactor auxiliary contact L N110VAC, 230VAC power supply (standby power connection) white white black sensor pad internal sensor pad N/O PB R IND M K1 24VDC, Power supply L1 L2 L3 auxiliary output auxiliary input K1 (auxiliary) start instantaneous button stop instantaneous button fuse motor protection, for example. Thermal circuit breaker 12 3 4 MC MC+VE control unit K1 – VE white white black black sensor pad Internal sensor pad L N link 31 13 23 N/O PB R IND 32 14 24 110VAC, 230VAC power supply (standby power supply connection) 22 Figure 17 shows an example of connection diagram for single contactor (single channel) 440F-C4000D application. Circuit status - power on - not present on sensor pad - reset button operated (if in manual reset mode) - machine start circuit enabled. Note: If the contactor is stuck in the ON position, the motor will not stop when the pad is in the ON position. Figure 18 shows an example connection diagram for two contactors and contactor monitoring (dual channel) 440F-C4000D applications.

    Circuit status - power on - not present on sensor pad - reset button operated (if in manual reset mode) - machine start circuit enabled. Note: If any of the contactors is stuck in the ON position, the motor will stop when the pad is placed and a fault is detected. M K1 K2 24VDC, power supply L1 L2 L3 auxiliary output auxiliary input K1 (AUX) K2 (auux) start instantaneous button stop instantaneous button fuse motor protection, such as thermal circuit breaker 12 3 4+31 MC MC 13 23 32 14 24 control unit K1 K2 positive contactor auxiliary contact A1 A2 white black wind sensor pad internal sensor pad Y2 Y4 Y6 reset IND Y1 Y3 Y5 110VAC, 230VAC power supply (standby power connection) M K1 24VDC, Power supply L1 L2 L3 auxiliary output auxiliary input K1 (auxiliary) start instantaneous button stop instantaneous button fuse motor protection, such as thermal circuit breaker 12 3 4 MC+control unit K1 – white white black sensor pad internal sensor pad A1 A2 link 31 13 Y2 Y4 Y6 reset IND 32 14 Y1 Y3 Y5 MC 110VAC, 230VAC power supply (standby power connection) 23 After the design of safety related control system is completed, Ensure that the response time assumed in 5.4.1 remains valid. If the value changes, the safety distance calculation needs to be repeated. Next consider the reset option. Under normal and fault conditions, the consequences of the selected reset scheme should be carefully considered to prevent the danger caused by accidental startup, etc. The time sequence diagrams of the two modes of the cushion subsystem are given below. Fig. 19 Manual reset mode Fig. 20 Relationship between automatic reset mode drive, reset and output. The relationship between the start and output manual reset modes can be reset via a button or remote button on the control unit or a voltage free contact in the machine safety related control system. The output of the system will remain closed until reset after power on, and the master/slave reset circuit may be required in complex systems with other power on interlocks (start interlocks). Automatic reset mode When used in the automatic reset mode, the control system of the machine will need a separate reset function to prevent the machine from starting after leaving the mat or after a temporary power failure or drop.

    fa405aeea632aa6912154382925a28b_副本.jpg

    ABB 07AC91D.jpg

    1666663047009.jpg

    18.jpg



    品牌:  Motorola 

    型號:MVME172-343 

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號