MVME162-431機(jī)器人模塊卡件
表模塊屬性設(shè)置參數(shù)項(xiàng)目選擇常規(guī)選項(xiàng)卡名稱(chēng)必填必須符合描述可選通信格式取決于所選的組件實(shí)例地址主機(jī)名地址目標(biāo)單元的地址主機(jī)名不適用連接參數(shù)組件實(shí)例大小通信格式數(shù)據(jù)表描述輸入選擇一個(gè)輸入數(shù)據(jù)產(chǎn)品信息輸入數(shù)據(jù)實(shí)時(shí)電壓和電流輸入數(shù)據(jù)真實(shí)實(shí)時(shí)功率,頻率輸入數(shù)據(jù)實(shí)際最大電壓和電流輸入數(shù)據(jù)真正最大功率,頻輸入數(shù)據(jù)實(shí)際電壓和電流輸入數(shù)據(jù)真實(shí)功率,頻率輸入數(shù)據(jù)真實(shí)電能表輸入數(shù)據(jù)報(bào)警和輸出狀態(tài)輸出儀器用于僅輸入連接儀器用于僅偵聽(tīng)連接配置實(shí)例是僅占位的連接選項(xiàng)卡或更大抑制模塊可選默認(rèn)未選中主要故障可選默認(rèn)單播連接未選中可選默認(rèn)選中僅當(dāng)與另一個(gè)控制器存在僅輸入連接時(shí)才使用僅偵聽(tīng)連接。年月通信第章完成后,單擊確定保存新模塊。模塊按照請(qǐng)求的數(shù)據(jù)包間隔更新其輸入標(biāo)簽?zāi)梢允褂闷渌幊桃粤硪环N方式顯示數(shù)據(jù)。實(shí)例以或浮點(diǎn)格式顯示數(shù)據(jù)。然而,實(shí)例將字符與數(shù)字字節(jié)值組合在一起。此程序以更具可讀性的方式顯示實(shí)例的內(nèi)容標(biāo)記上的指令啟用轉(zhuǎn)換。第一指令復(fù)制模塊輸入數(shù)據(jù)標(biāo)簽的前個(gè)字節(jié)。指令將序列號(hào)字符串長(zhǎng)度設(shè)置為。最后一個(gè)指令從模塊輸入數(shù)據(jù)標(biāo)簽復(fù)制序列號(hào),該標(biāo)簽從元素字節(jié)開(kāi)始。年月第章通信指令的目的地位于具有用戶(hù)定義數(shù)據(jù)類(lèi)型的標(biāo)簽中。目標(biāo)標(biāo)記以這種方式顯示數(shù)據(jù)。通信有關(guān)協(xié)議的完整描述,請(qǐng)參閱以下文件,可從:下載。功能支持在裝置中,訂購(gòu)時(shí)帶有可選的通信。此外,在訂購(gòu)的裝置中支持可選以太網(wǎng)通信。必須配置電源監(jiān)視器中的通信參數(shù)。請(qǐng)參閱本手冊(cè)的單元配置部分。重要提示我們建議您使用配置或?qū)懭雴卧?,并使用讀取。年月通信第章單元支持以下功能讀取保持寄存器讀取輸入寄存器寫(xiě)入一個(gè)保持寄存器寫(xiě)入多個(gè)寄存器診斷子功能代碼讀取特殊寄存器供應(yīng)商特定廣播模式地址上的寫(xiě)入命令在此扇區(qū)中,地址以?xún)煞N方式表示。地址表示為位輸入寄存器地址例如,與功能代碼一起使用。物理地址是包含在通信幀中的字地址的十六進(jìn)制表示。功能可與地址一起使用,方法是用代替第一個(gè)數(shù)字例如。因此,區(qū)分函數(shù)和返回相同的數(shù)據(jù)。為了避免由于信號(hào)反射或線路耦合引起的錯(cuò)誤,必須在主站和離主站最遠(yuǎn)的功率監(jiān)視器的端口處連接終端電阻器。在中,您可以在和之間安裝跳線,以在內(nèi)部和之間施加所需的終端電阻。
Table Module Attribute Setting Parameter Item Selection General Tab Name Mandatory must conform to description Optional communication format depends on the selected component instance address Host name Address Target unit address Host name Not applicable to connection parameters Component instance size Communication format Data table Description Input Select an input data Product information Input data Real time voltage and current Input data Real time power, The actual maximum voltage and current input data of the frequency input data are the real maximum power, the actual voltage and current input data of the frequency input data are the real power, Frequency input data Real electric energy meter Input data alarm and output status Output instrument is used for input connection only Instrument is used for listening connection Connection tab or larger suppression module whose configuration instance is only occupied Optional default is not selected Main fault Optional default unicast connection is not selected Optional default is selected Only listen connection is used when there is an input only connection with another controller. Click OK to save the new module after the completion of the month month communication chapter. The module updates its input tags at the requested packet interval You can use other programming to display the data in another way. Instance displays data in or floating point format. However, instances combine characters with numeric byte values. This program displays the instructions on the content tag of the instance in a more readable way to enable conversion. The first instruction copy module inputs the first byte of the data tag. The directive sets the serial number string length to. The last instruction copies the serial number from the module input data tag, which starts with the element byte. The purpose of the communication instructions in the chapter of January, is in the tags with user-defined data types. The target tag displays the data in this way. For a complete description of the communication related protocols, please refer to the following files, which can be downloaded from:. The function is supported in the device with optional communication when ordering. In addition, optional Ethernet communication is supported in the ordered devices. The communication parameters in the power monitor must be configured. Refer to the unit configuration section of this manual. Important We recommend that you use the configuration or write unit, and use read. The unit in the chapter of the month month communication supports the following functions: read the holding register, read the input register, write one holding register, write multiple registers, diagnose the subfunction code, read the special register, read the write command on the address of the supplier's specific broadcast mode in this sector, and the address is expressed in two ways. The address is represented as a bit input register address for example, used with function codes. The physical address is a hexadecimal representation of the word address contained in the communication frame. The function can be used with the address by replacing the first number with e.g. Therefore, distinguish between functions and return the same data. To avoid errors caused by signal reflection or line coupling, a terminating resistor must be connected at the port of the master station and the power monitor farthest from the master station. In, you can install jumpers between and to apply the desired terminating resistance between the inside and.