中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過低,為保證更佳的瀏覽體驗,請點擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設(shè)備有限公司網(wǎng)站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

MVME162-202工控備件機(jī)器人模塊

MVME162-202工控備件機(jī)器人模塊

MVME162-202工控備件機(jī)器人模塊從控制單元到墊子的電線可以使用導(dǎo)線埋在地板中或通過邊緣裝飾件。此類安裝建議使用撓性導(dǎo)管。詳見第節(jié)。確定接線方法,并確定控制單元接線墊的輸入和輸出連接點。最終細(xì)節(jié)準(zhǔn)備安裝布局和電路的工作計劃和圖紙。建議將所有測量和計算記錄并保存在機(jī)器的技術(shù)文件中。第節(jié)安裝和調(diào)試開始安裝前,應(yīng)完整閱讀本手冊。開始工作前,請仔細(xì)學(xué)習(xí)本節(jié)內(nèi)容。安裝和調(diào)試應(yīng)由系統(tǒng)設(shè)計師監(jiān)督。需要一名...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

MVME162-202工控備件機(jī)器人模塊

    MVME162-202工控備件機(jī)器人模塊

    從控制單元到墊子的電線可以使用導(dǎo)線埋在地板中或通過邊緣裝飾件。此類安裝建議使用撓性導(dǎo)管。詳見第節(jié)。確定接線方法,并確定控制單元接線墊的輸入和輸出連接點。最終細(xì)節(jié)準(zhǔn)備安裝布局和電路的工作計劃和圖紙。建議將所有測量和計算記錄并保存在機(jī)器的技術(shù)文件中。第節(jié)安裝和調(diào)試開始安裝前,應(yīng)完整閱讀本手冊。開始工作前,請仔細(xì)學(xué)習(xí)本節(jié)內(nèi)容。安裝和調(diào)試應(yīng)由系統(tǒng)設(shè)計師監(jiān)督。需要一名熟悉工業(yè)布線實踐的機(jī)械技術(shù)人員和一名電工進(jìn)行安裝。調(diào)試應(yīng)由在安全安裝方面有經(jīng)驗的訓(xùn)練有素的電氣技術(shù)人員進(jìn)行。需要以下專用工具預(yù)絕緣對接接頭的壓接工具圖連接器例如圖帶熱收縮反射器附件的熱風(fēng)槍如隔離并鎖定機(jī)器電源。檢查地板是否干凈無碎屑,任何埋地管道或其他布線是否正確到位。拆開墊子,小心保持平整,不要拉扯電線。將墊子放置在地板上的計劃位置,連接線位于檢測區(qū)域的外圍。根據(jù)圖將墊段連接在一起。圖注意墊線具有黑色外層。兩個具有黑色內(nèi)護(hù)套,兩個具有白色內(nèi)護(hù)套位置見圖??刂茊卧幍膫鞲衅鲏|白黑白白黑黑黑黑黑黑白白黑終端留有足夠的線尾長度,以便在更換墊的情況下重新制作連接,但確?;ミB線能夠輕松地安裝在邊緣裝飾件下,而不會壓傷。使用下圖所示的對接連接器連接電線。如果墊線需要延長,例如前墊到后墊連接和控制單元連接,則使用額外的一對對接連接器和一段雙導(dǎo)線參見布線規(guī)范第節(jié)。圖組合修剪固定安裝中使用的所有活動組合修剪部分必須斜接至。這有助于安裝,并有助于保持傳感區(qū)域的整體靈敏度。圖周邊飾板固定如果控制單元的接線未埋置,則在電線入口和出口位置切割周邊飾板,并切割飾板坡度以適合所選導(dǎo)管系統(tǒng)。小心完全開槽,以便周邊裝飾件的任何彎曲都不會夾住電線。確保沒有可能損壞導(dǎo)線的銳邊或毛刺。圖進(jìn)入電纜槽周邊飾板底部的墊線建議切口的飾板固定件詳圖撓性導(dǎo)管入口建議切口的鋁制內(nèi)角周邊飾板與和一起使用鋁制外角周邊飾條與及一起使用應(yīng)力釋放夾具撓性導(dǎo)管切口槽此處,在鋒利的邊緣上使用邊緣護(hù)環(huán)剝下的電線并插入壓接筒。使用壓接工具上正確的空腔尺寸壓接。使用帶導(dǎo)流板的加熱槍加熱壓接接頭,直到管道收縮,粘合劑收縮并流動。和和對于外部拐角裝飾件,使用。對于內(nèi)部拐角裝飾件使用,和使用帶撓性導(dǎo)管的應(yīng)力消除夾具將所有裝飾件切割成,如圖所示。

    The wires from the control unit to the mat can be buried in the floor or through the edge trim using wires. Flexible conduit is recommended for such installations. See Section for details. Determine the wiring method, and determine the input and output connection points of the control unit wiring pad. Final details Prepare work plans and drawings for installation layout and circuits. It is recommended that all measurements and calculations be recorded and kept in the technical documentation of the machine. Section Installation and Commissioning This manual should be read completely before installation. Please study this section carefully before starting work. Installation and commissioning shall be supervised by the system designer. A mechanical technician familiar with industrial wiring practice and an electrician are required for installation. The commissioning shall be carried out by trained electrical technicians with experience in safe installation. The following special tools are required for crimping the pre insulated butt joint Fig. Connector, e.g. Fig. Hot air gun with heat shrinkable reflector accessories, e.g. isolating and locking the machine power supply. Check that the floor is clean and free of debris and that any buried piping or other wiring is in place. Remove the mat and be careful to keep it flat. Do not pull the wire. Place the mat at the planned position on the floor, and the connecting line is located at the periphery of the detection area. Connect the cushion sections according to the figure. Note that the padding line has a black outer layer. Two have black inner sheaths and two have white inner sheaths. The sensor pad white black white black black black black black black black black white black black white black black black white black terminal at the control unit has enough tail length to facilitate the connection when the pad is replaced, but ensure that the interconnect can be easily installed under the edge trim without crushing. Connect the wires using the butt connectors shown below. If the pad wire needs to be extended, such as the front pad to rear pad connection and the control unit connection, use an additional pair of butt connectors and a section of double wires. See Section of Wiring Specifications. All movable combination trim parts used in the figure combination trim fixing installation must be mitered to. This facilitates installation and helps maintain the overall sensitivity of the sensing area. Fig. Fixation of peripheral trim panel If the wiring of the control unit is not embedded, cut the peripheral trim panel at the wire inlet and outlet, and cut the trim panel slope to fit the selected conduit system. Be careful to fully slot so that any bending of the surrounding trim will not trap the wire. Make sure there are no sharp edges or burrs that could damage the wires. Fig. The padding line at the bottom of the peripheral trim panel of the cable tray. Details of the trim panel fastener with the recommended cut at the flexible conduit entrance. The aluminum inner corner peripheral trim panel with the recommended cut is used together with and. The aluminum outer corner peripheral trim strip is used together with and. The stress relief clamp is used in the flexible conduit cut slot. Here, use the edge guard ring to peel off the wires on the sharp edge and insert the crimping cylinder. Crimp with the correct cavity size on the crimping tool. Use a heat gun with a deflector to heat the crimp joint until the pipe shrinks and the adhesive shrinks and flows. And and for the exterior corner trim, use. For internal corner trim use, and use a stress relief fixture with flexible conduit to cut all trim into as shown.

    fa405aeea632aa6912154382925a28b_副本.jpg

    ABB PFSK151.jpg

    ABB 5SHY3545L0009.jpg

    9.jpg

    23.jpg

    18.jpg



    品牌:  Motorola 

    型號:MVME162-202 

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號