目錄首選可用性目錄。編號為粗體。出版物A117-CA001A-EN-P公告電機(jī)保護(hù)斷路器公告電機(jī)保護(hù)電路斷路器為單個(gè)電機(jī)負(fù)載提供短路和過載保護(hù)。預(yù)裝的內(nèi)部處理器便于安裝和布線。一般信息目錄產(chǎn)品選擇電機(jī)保護(hù)電流范圍0.1630 A UL列出的電機(jī)負(fù)載? 短路保護(hù)? 過載保護(hù)可見跳閘指示高電流限制高開關(guān)容量認(rèn)證標(biāo)準(zhǔn)符合電機(jī)保護(hù)斷路器可提供以下保護(hù)和控制功能。斷開電機(jī)分支電路分支電路、短路保護(hù)(磁保護(hù))過載保護(hù)(熱保護(hù))開關(guān)(手動(dòng))在北美,電氣規(guī)范要求單個(gè)電機(jī)分支電路由UL/CSA認(rèn)證的保險(xiǎn)絲、斷路器或自保護(hù)雙聯(lián)電機(jī)控制器保護(hù)。D和F機(jī)架:D和F框架電機(jī)保護(hù)斷路器可能有2個(gè)cULus列表——作為手動(dòng)、自保護(hù)雙聯(lián)電機(jī)控制器和手動(dòng)電機(jī)控制器(具有電機(jī)斷開和組安裝的可選批準(zhǔn))。當(dāng)UL/CSA列為手動(dòng)、自保護(hù)雙電機(jī)控制器時(shí),電機(jī)保護(hù)斷路器提供了保護(hù)和控制單個(gè)電機(jī)分支電路的所有必要的NEC/CEC要求,無需額外的保護(hù)裝置。在某些較高的電壓和電流(尤其是600V)下,一些D和F框架設(shè)備僅被UL/CSA列為手動(dòng)電機(jī)控制器(具有電機(jī)斷開和組安裝的可選批準(zhǔn))。在NEC/CEC集團(tuán)安裝中,必須按照要求使用上游分支電路、短路保護(hù)裝置(BCPD)的適當(dāng)規(guī)則應(yīng)用這些裝置。電機(jī)保護(hù)斷路器的具體額定值見第2-18頁的表??蚣埽嚎蚣茈姍C(jī)保護(hù)斷路器經(jīng)UL認(rèn)證/CSA認(rèn)證為手動(dòng)電機(jī)控制器(具有電機(jī)斷開和組安裝的可選批準(zhǔn))。在NEC/CEC集團(tuán)安裝中,必須按照要求使用上游分支電路、短路保護(hù)裝置(BCPD)的適當(dāng)規(guī)則應(yīng)用這些裝置。電機(jī)保護(hù)斷路器的具體額定值見第2-18頁的表-一、 J和L框架:如第2-9頁表格所示,-I、J和L型框架電機(jī)保護(hù)斷路器被列為斷路器。在這些情況下,電機(jī)保護(hù)斷路斷路器提供了保護(hù)和控制單個(gè)電機(jī)分支電路的所有必要的NEC/CEC要求,無需額外的保護(hù)裝置。
catalogs Prefer availability cat. nos. are bold. Publication A117-CA001A-EN-P Bulletin Motor Protection Circuit Breakers The Bulletin Motor Protection Circuit Breakers provide short circuit and overload protection for individual motor loads. Ftoryinstalled internal cessories make installation and wiring easy. General Information Table of Contents Product Selection Motor Protection Current Range 0.1630 A UL Listed for Motor Loads ? Short Circuit Protection ? Overload Protection Visible Trip Indication High Current Limiting High Switching Capity Certifications Standards pliance Motor Protection Circuit Breakers may provide the following protective and control functions. Disconnect for Motor Branch Circuit Branch-Circuit, Short-Circuit Protection (Magnetic Protection) Overload Protection (Thermal Protection) Switching (Manual) In North America, electrical codes require that an individual Motor Branch Circuit be protected by a UL/CSA Listed Fuse, Circuit Breaker or Self-Protected bination Motor Controller. D and F Frames: The D and F frame Motor Protection Circuit Breakers may have 2 cULus Listings – as Manual, Self-Protected bination Motor Controllers and as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). When UL/CSA listed as Manual, Self-Protected bination Motor Controllers, the Motor Protection Circuit Breakers provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. At some higher voltages and currents (particularly at 600V), a few of the D and F frame devices are only UL/CSA Listed as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on page 2-18 for the specific ratings of eh Motor Protection Circuit Breaker. Frame: The frame Motor Protection Circuit Breakers are UL Listed/CSA Certified as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on page 2-18 for the specific ratings of eh Motor Protection Circuit Breaker. -I, J and L Frames: The -I, J and L frame Motor Protection Circuit Breakers are cULus Listed as Circuit Breakers as shown in the table on page 2-9. In these cases, the Motor Protection Circuit Breakers provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices.