MVME147SC-2工控模塊備件
僅600V驅(qū)動器??蚣?和7為雙電壓驅(qū)動器,可在600V或690V下運行。重要提示:框架3、4和5不得用于框架6或更大驅(qū)動器的同軸輸入共享應用。有關詳細信息,請聯(lián)系當?shù)亓_克韋爾自動化銷售辦公室或Allen-Bradley分銷商??偩€端子未配備輸入框架6和7驅(qū)動器。600V,三相驅(qū)動器–IP20,這些驅(qū)動器具有雙電流額定值;一個用于正常負載應用,一個用于重載應用(在括號中)。驅(qū)動器可在任一額定值下運行。600690V,三相驅(qū)動–IP00,開放型600V輸入690V輸入框架尺寸輸出安培正常負載Hp重載Hp輸出安培正常功率kW重載kW續(xù)。1分鐘3秒續(xù)1分鐘3節(jié)12(9.1)13.2(13.7)18 10 7.5這些驅(qū)動器具有雙電流額定值;一個用于正常負載應用,一個用于重載應用(在括號中)。驅(qū)動器可在任一額定值下運行。第11章確定默認過濾和Coon Mode Cap跳線配置。“J”=已安裝,“A”=已刪除。當連接到具有不受控制的前端的coon輸入應用中的60 Hp或更高的驅(qū)動器時,備用600V額定值。還可與內(nèi)部制動器IGBT PowerFlex 753驅(qū)動器58羅克韋爾自動化出版物PFLEX-SG002I-EN-P一起提供-2015年5月法蘭安裝前部=IP20,開放型,Bk/散熱器=IP66,4X 380…480V型,三相驅(qū)動器480V輸入400V輸入框架尺寸輸出電流正常負載Hp重載Hp輸出電流正常功率kW重載kW續(xù)。至少需要一個用戶安裝的帶IP00開放式驅(qū)動器的儀表套件。某些驅(qū)動器具有雙電流額定值;一個用于正常負載應用,一個用于重載應用(在括號中)。驅(qū)動器可在任一額定值下運行。第11章確定默認過濾和Coon Mode Cap跳線配置?!癑”=已安裝,“A”=已刪除。600V三相驅(qū)動輸出電流(續(xù))。1分鐘3秒正常負載Hp重型Hp框架這些驅(qū)動器具有雙電流額定值;一個用于正常負載應用,一個用于重載應用(在括號中)。驅(qū)動器可在任一額定值下運行。PowerFlex 753驅(qū)動羅克韋爾自動化出版物PFLEX-SG002I-EN-P-2015年5月59 IP54,類型12 380480V,三相驅(qū)動480V輸入400V輸入框架尺寸輸出安培正常負載Hp重載Hp輸出安培正常功率kW重載kW續(xù)。某些驅(qū)動器具有雙電流額定值;一個用于正常負載應用,一個用于重載應用(在括號中)。驅(qū)動器可在任一額定值下運行。第11章確定默認過濾和Coon Mode Cap跳線配置?!癑”=已安裝,“A”=已刪除。也可與內(nèi)部制動器IGBT(20F1xxxxxxx A xxxxxx)一起提供。PowerFlex 753 Drive 60羅克韋爾自動化出版物PFLEX-SG002I-EN-P-2015年5月IP54,12型(續(xù))框架3、4和5僅為600V驅(qū)動器??蚣?和7為雙電壓驅(qū)動器,可在600V或690V下運行。重要提示:框架3、4和5不得用于框架6或更大驅(qū)動器的同軸輸入共享應用。有關詳細信息,請聯(lián)系當?shù)亓_克韋爾自動化銷售辦公室或Allen-Bradley分銷商??偩€端子未配備輸入框架6和7驅(qū)動器。600V三相驅(qū)動輸出電流(續(xù))。1分鐘3秒正常負載Hp重型Hp框架這些驅(qū)動器具有雙電流額定值;一個用于正常負載應用,一個用于重載應用(在括號中)。驅(qū)動器可在任一額定值下運行。600690V,三相驅(qū)動器600V輸入690V輸入框架尺寸輸出安培正常負載Hp重載Hp輸出安培這些驅(qū)動器具有雙電流額定值;一個用于正常負載應用,一個用于重載應用(在括號中)。驅(qū)動器可在任一額定值下運行。第11章確定默認過濾和Coon Mode Cap跳線配置?!癑”=已安裝,“A”=已刪除。當連接到具有不受控制的前端的coon輸入應用中的60 Hp或更高的驅(qū)動器時,備用600V額定值。還可提供內(nèi)部制動器IGBT PowerFlex 753 Drive Rockwell Automation出版物PFLEX-SG002I-EN-P-2015年5月61近似尺寸和重量尺寸以英寸為單位-重量以千克(磅)IP00/IP20為單位,開放式框架重量為近似值。
are 600V only drives. Frames 6 and 7 are dual voltage drives and can be operated at 600V or 690V . Important: Frames 3, 4, and 5 must NOT be used in coon input sharing applications with Frame 6 or larger drives. For details, contt your local Rockwell Automation sales offi ce or Allen-Bradley Distributor. Bus terminals are not supplied with input Frame 6 and 7 drives. 600V , Three-Phase Drives – IP20, These drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis).The drive may be operated at either rating. 600690V , Three-Phase Drives – IP00, Type Open 600V Input 690V Input Frame Size Output Amps Normal Duty Hp Heavy Duty Hp Output Amps Normal Duty kW Heavy Duty kW Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec. 12 (9.1) 13.2 (13.7) 18 10 7.5 These drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis).The drive may be operated at either rating. The 11th charter determines default Filtering and Coon Mode Cap jumper confi guration. “J” = Installed, “A” = Removed. Alternate 600V ratings when connected to drives 60 Hp and greater in coon input applications with uncontrolled front ends. Also available with internal Brake IGBT PowerFlex 753 Drive 58 Rockwell Automation Publication PFLEX-SG002I-EN-P - May 2015 Flange Mount Front = IP20, Type Open, Bk/Heatsink = IP66, Type 4X 380...480V , Three-Phase Drives 480V Input 400V Input Frame Size Output Amps Normal Duty Hp Heavy Duty Hp Output Amps Normal Duty kW Heavy Duty kW Cont. 1 Min. require a user installed fl ange kit with an IP00, Type Open drive. Some drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis). The drive may be operated at either rating. The 11th charter determines default Filtering and Coon Mode Cap jumper confi guration. “J” = Installed, “A” = Removed. 600V , Three-Phase Drives Output Amps Cont. 1 Min. 3 Sec. Normal Duty Hp Heavy Duty Hp Frame These drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis).The drive may be operated at either rating. PowerFlex 753 Drive Rockwell Automation Publication PFLEX-SG002I-EN-P - May 2015 59 IP54, Type 12 380480V , Three-Phase Drives 480V Input 400V Input Frame Size Output Amps Normal Duty Hp Heavy Duty Hp Output Amps Normal Duty kW Heavy Duty kW Cont. Some drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis). The drive may be operated at either rating. The 11th charter determines default Filtering and Coon Mode Cap jumper confi guration. “J” = Installed, “A” = Removed. Also available with internal Brake IGBT (20F1xxxxxxx A xxxxxx). PowerFlex 753 Drive 60 Rockwell Automation Publication PFLEX-SG002I-EN-P - May 2015 IP54, Type 12 (continued) Frames 3, 4 and 5 are 600V only drives. Frames 6 and 7 are dual voltage drives and can be operated at 600V or 690V . Important: Frames 3, 4, and 5 must NOT be used in coon input sharing applications with Frame 6 or larger drives. For details, contt your local Rockwell Automation sales offi ce or Allen-Bradley Distributor. Bus terminals are not supplied with input Frame 6 and 7 drives. 600V , Three-Phase Drives Output Amps Cont. 1 Min. 3 Sec. Normal Duty Hp Heavy Duty Hp Frame These drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis).The drive may be operated at either rating. 600690V , Three-Phase Drives 600V Input 690V Input Frame Size Output Amps Normal Duty Hp Heavy Duty Hp Output Amps These drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis).The drive may be operated at either rating. The 11th charter determines default Filtering and Coon Mode Cap jumper confi guration. “J” = Installed, “A” = Removed. Alternate 600V ratings when connected to drives 60 Hp and greater in coon input applications with uncontrolled front ends. Also available with internal Brake IGBT PowerFlex 753 Drive Rockwell Automation Publication PFLEX-SG002I-EN-P - May 2015 61 Approximate Dimensions and Weights Dimensions are in (in.) - weights are in kg (lb) IP00/IP20, Type Open Frame Weights are approximate.