中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過低,為保證更佳的瀏覽體驗,請點擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設(shè)備有限公司網(wǎng)站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

MIV08A-1-B5工控模塊系統(tǒng)備件

MIV08A-1-B5工控模塊系統(tǒng)備件

MIV08A-1-B5工控模塊系統(tǒng)備件與這些區(qū)域的間隙應(yīng)大于或等于電纜直徑。3.保持電纜彎曲在第7頁規(guī)范中列出的彎曲半徑內(nèi)。以下列出了電纜彎曲半徑的一般準(zhǔn)則,但是,單個電纜可能有其他限制:網(wǎng)絡(luò)電纜的靜態(tài)或一次性彎曲半徑為電纜直徑的十二倍。4.安裝這些電纜時應(yīng)遵守這些限制:防止電纜在15025(61 in.)安裝區(qū)域內(nèi)彎曲。僅在彎曲區(qū)域?qū)㈦娎|彎曲為特定形狀。沿電纜線路以3米(10英尺)的間隔提供電纜...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

MIV08A-1-B5工控模塊系統(tǒng)備件

    MIV08A-1-B5工控模塊系統(tǒng)備件

    與這些區(qū)域的間隙應(yīng)大于或等于電纜直徑。3.保持電纜彎曲在第7頁規(guī)范中列出的彎曲半徑內(nèi)。以下列出了電纜彎曲半徑的一般準(zhǔn)則,但是,單個電纜可能有其他限制:網(wǎng)絡(luò)電纜的靜態(tài)或一次性彎曲半徑為電纜直徑的十二倍。4.安裝這些電纜時應(yīng)遵守這些限制:防止電纜在150±25(6±1 in.)安裝區(qū)域內(nèi)彎曲。僅在彎曲區(qū)域?qū)㈦娎|彎曲為特定形狀。沿電纜線路以3米(10英尺)的間隔提供電纜支架,以減少連接器和電纜上其他部件的張力和彎曲。5.施加0.81.2 Nm(711 lbin)的扭矩,使控制裝置完全就位并固定連接。注意:如果在IDM系統(tǒng)通電時連接或斷開電纜,可能會發(fā)生電弧或意外運動。在IDM系統(tǒng)上工作之前,斷開電源并等待IPIM模塊警告中所示的整個時間間隔,或者驗證IPIM模塊上的總線電壓是否小于50V。如果不遵守此預(yù)防措施,可能會導(dǎo)致嚴(yán)重的人身傷害或生命損失,并對產(chǎn)品造成損壞。有限彎曲區(qū)安裝區(qū)域150±25(6±1.0)安裝區(qū)域150?5(6±1.02090-CNSSPRS-AA所示M12直角內(nèi)螺紋插頭M12直外螺紋插頭尺寸為英寸和英寸。). 6 Kinetix 6000M A系列網(wǎng)線出版物2090-IN034B-EN-P-2012年3月原理圖和連接器引腳圖該圖提供了Kinetix 6000 M網(wǎng)線的導(dǎo)線顏色和引腳。網(wǎng)絡(luò)電纜示意圖網(wǎng)絡(luò)電纜引出線網(wǎng)絡(luò)電纜配置不用于連接到IPIM模塊。1 4 2 3 5 1 4 2 5藍(lán)白/藍(lán)白/棕棕色屏蔽雙絞線屏蔽線連接1。屏蔽連接到兩個連接器的螺紋金屬端。綠色公連接器引腳母連接器引腳2090 CNSSPRS AAxx直陽和直角陰2090 CNSRPSS AAxx直角陽和直陰2090 CNSSPSS AAxx直陰和直陽2090 CNRSPRS AAxx直角陰和直角陽Kinetix 6000M系列A網(wǎng)絡(luò)電纜7出版物2090-IN034B-EN-P-2012年3月附加規(guī)范在Kinetix Motion處理器技術(shù)數(shù)據(jù)出版物GMC-TD004中提供了eh電纜的規(guī)格。附加資源這些文件包含羅克韋爾自動化公司相關(guān)產(chǎn)品的附加信息。您可以在以下位置查看或下載出版物:http://../literature.要訂購技術(shù)文件的紙質(zhì)副本,請聯(lián)系您的Allen-Bradley?分銷商或羅克韋爾自動化?銷售代表。

    Clearance from these areas should be greater than or equal to the cable diameter. 3. Keep cable bends within the bend radius listed in the Specifications on page 7. General guidelines for the bend radius of a cable are listed below, however, individual cables may have additional restrictions: Network cables have a static or one-time bend radius of twelve times the cable diameter. 4. Observe these restrictions when installing these cables: Prevent the cable from flexing within 150 ±25  (6 ±1 in.) installation areas. Bend cables to a specific shape only in the bend zone area. Provide cable supports at 3 m (10 ft) intervals along the cable run to uce tension and flexing at the connectors and other features on the cable. 5. Apply 0.81.2 Nm (711 lbin) of torque to fully seat the contts and secure the connection. ATTENTION: Arcing or unexpected motion can occur if cables are connected or disconnected while power is applied to the IDM system. Before working on an IDM system, disconnect power and wait the full time interval as indicated in the warning on the IPIM module or verify the  bus voltage at the IPIM module measures less than 50V . Failure to observe this precaution could result in severe bodily injury or loss of life, and damage to the product will occur. Limited Bend Zone Installation Area 150  ± 25 (6 ± 1.0) Installation Area 150  ± 25 (6 ± 1.0) 2090-CNSSPRS-AA shown M12 Right-angle Female Plug M12 Straight Male Plug Dimensions are in  and (in.). 6 Kinetix 6000M Series A Network Cable Publication 2090-IN034B-EN-P - March 2012 Schematic and Connector Pinouts The diagrams provides wire colors and pinouts for the Kinetix 6000M network cables. Network  Cable Schematic Network  Cable Pinouts Network  Cable Configurations  Not for connection to an IPIM module. 1 4 2 3 5 1 4 2 3 5 Blue White/Blue White/Brown Brown Shield Twisted Pair Shield Wire Connection 1. Shield connects to the threaded metal end of both connectors.   Green Male Connector Pinouts Female Connector Pinouts 2090-CNSSPRS-AAxx Straight Male and Right-angle Female 2090-CNSRPSS-AAxx Right-angle Male and Straight Female  2090-CNSSPSS-AAxx Straight Male and Straight Female 2090-CNRSPRS-AAxx Right-angle Male and Right-angle Female  Kinetix 6000M Series A Network Cable 7 Publication 2090-IN034B-EN-P - March 2012 Specifications Additional specifications for eh cable are available in the Kinetix Motion cessories Technical Data, publication GMC-TD004. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. You can view or download publications at http://../literature. To order paper copies of technical documentation, contt your Allen-Bradley? distributor or Rockwell Automation? sales representative. 

    fa405aeea632aa6912154382925a28b_副本.jpg

    GE VMIVME-7698-345 350-017698-345 B.jpg

    9.jpg

    23.jpg



    品牌:  Motorola 

    型號:MIV08A-1-B5 

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號