ICS TRIPLEX T8912機(jī)械設(shè)備卡件
? ues將代替測(cè)量值,可在啟動(dòng)或測(cè)試期間使用,以驗(yàn)證輸出繼電器是否正常工作。只有當(dāng)電機(jī)停止且沒(méi)有跳閘、報(bào)警或啟動(dòng)塊激活時(shí),輸出繼電器才能強(qiáng)制運(yùn)行。如果任何繼電器被強(qiáng)制運(yùn)行,則繼電器將從其正常狀態(tài)(無(wú)跳閘、報(bào)警或閉塞)切換至其激活狀態(tài)。此時(shí),相應(yīng)的繼電器指示燈將點(diǎn)亮。選擇“禁用”將使輸出繼電器重新投入使用。如果469測(cè)量相電流或控制功率循環(huán),則繼電器的強(qiáng)制操作設(shè)定值將自動(dòng)禁用,輸出繼電器將恢復(fù)到正常狀態(tài)。如果強(qiáng)制任何繼電器,469在用LED將閃爍,表明469未處于保護(hù)模式。4.14.5測(cè)試模擬輸出除模擬模式外,在啟動(dòng)或測(cè)試期間,可使用測(cè)試模擬輸出設(shè)定值組來(lái)驗(yàn)證模擬輸出是否正常工作。只有當(dāng)電機(jī)停止且沒(méi)有跳閘、報(bào)警或啟動(dòng)塊激活時(shí),才能強(qiáng)制模擬輸出。當(dāng)FORCE ANALOG OUTPUTS FUNCTION(強(qiáng)制模擬輸出功能)為“Enabled”(啟用)時(shí),輸出將強(qiáng)制值反映為4至20 mA或0至1 mA范圍的百分比。選擇“Disabled”(禁用)將使所有四個(gè)模擬輸出通道重新投入使用,反映為每個(gè)通道編程的參數(shù)。如果469測(cè)量相電流或循環(huán)控制電源,則FORCE ANALOG OUTPUTS FUNCTION(強(qiáng)制模擬輸出功能)將自動(dòng)禁用,所有模擬輸出將恢復(fù)到正常狀態(tài)。每當(dāng)模擬輸出被強(qiáng)制時(shí),469在用LED將閃爍,表明469 S13 469 TESTING 4 4.14.6 COMM PORT MONITOR(通信端口監(jiān)視器)在對(duì)通信問(wèn)題進(jìn)行故障排除的過(guò)程中,查看從某個(gè)主設(shè)備首先傳輸?shù)?69的數(shù)據(jù),然后查看469傳輸回該主設(shè)備的數(shù)據(jù)非常有用。此處顯示的消息應(yīng)該可以查看該數(shù)據(jù)??梢员O(jiān)控三個(gè)通信端口中的任何一個(gè)。清除通信緩沖區(qū)后,從被監(jiān)控的通信端口接收的任何數(shù)據(jù)將存儲(chǔ)在Rx1和Rx2緩沖區(qū)中,“//”用作消息之間的字符分隔符。如果469發(fā)送消息,它將出現(xiàn)在Tx1和Tx2緩沖器中。除這些緩沖器外,還有一條消息將指示狀態(tài)管理繼電器GE電源管理4.15 S14雙速電機(jī)4設(shè)定點(diǎn)編程4.15 S15雙速電機(jī)4.15.1說(shuō)明雙速電機(jī)功能為兩個(gè)不同滿載值的雙速電機(jī)提供適當(dāng)保護(hù)。該算法使用兩種速度的常用熱容量寄存器值將每種速度下的加熱集成到一個(gè)熱模型中。如果使用雙速電機(jī)功能,ASSIGNABLE INPUT4專(zhuān)用于雙速電機(jī)監(jiān)視器,端子D22和D23用于觸點(diǎn)閉合。觸點(diǎn)閉合表示電機(jī)處于速度2。如果輸入打開(kāi),則表示電機(jī)處于速度1。這允許469確定在任何給定時(shí)間點(diǎn)應(yīng)激活哪些設(shè)定點(diǎn)。SPEED2 MIN ALLOWABLE LINE VOLTAGE(速度2最小允許線路電壓):80%范圍:70至95%;步驟:1僅當(dāng)選擇了電壓相關(guān)曲線樣式時(shí)才顯示消息SPEED2 ISTALL@MIN Vline:4.80 x FLA范圍:2.00至15.00 x FLA;步驟:僅當(dāng)選擇了電壓相關(guān)曲線樣式時(shí)才顯示0.01消息SPEED2 SAFE STALL@MIN Vline:2.0 s范圍:0.5至999.9秒;步驟:僅當(dāng)選擇“電壓相關(guān)曲線樣式”時(shí)才顯示0.1消息SPEED2 ACL INTERSECT@MIN Vline:3.80 x FLA范圍:2.00至Istall@Min_Vlinex FLA;步驟:僅當(dāng)選擇了電壓相關(guān)曲線樣式SPEED2 4.15 S14雙速電機(jī)4設(shè)定點(diǎn)編程4時(shí),才會(huì)看到0.01消息。速度1的所有熱模型參數(shù)設(shè)置將與速度2相同。此處可為速度2、高速編程第二過(guò)載曲線設(shè)置。4.15.3速度2欠電流增加第二個(gè)欠電流跳閘或報(bào)警級(jí)別可能很有用,因?yàn)樗鼘⒅甘惧e(cuò)誤的速度是否使用了錯(cuò)誤的設(shè)定值,即速度2的正常運(yùn)行電流可能是欠電流,速度為更多的BLOCK SPEED2 U/C FROM START:0 s Range:0 to 15000 s,步驟1速度2 U/C alarm:Off Range:Off,Latched,未鎖定的SPEED2 U/C警報(bào)拾取:0.70 x FLA范圍:0.10至0.95 x FLA,步驟0.01 SPEED2 U/C警報(bào)延遲:1 s范圍:1至60秒,步驟1 SPEED2 U-C警報(bào)事件:關(guān)閉范圍:打開(kāi),關(guān)閉速度2 U/C跳閘:0ff范圍:關(guān)閉,鎖定,未鎖定速度2 U/C跳閘傳感器:0.70 x FLA范圍:0.10 4.15 S14雙速電機(jī)4 4.15.4速度2加速度雙速電機(jī)功能提供了兩個(gè)額外的加速計(jì)時(shí)器。一個(gè)計(jì)時(shí)器用于從停止?fàn)顟B(tài)啟動(dòng)速度2。另一個(gè)是用于從速度1轉(zhuǎn)換到速度2的加速計(jì)時(shí)器。此外,雖然t
? ues will be substituted for the measured values may be used during startup or testing to verify that the output relays are functioning correctly. The output relays can only be forced to operate only if the motor is stopped and there are no trips, alarms, or start blocks active. If any relay is forced to operate, the relay will toggle from its normal state when there are no trips, alarms, or blocks to its active state. The appropriate relay indicator will illuminate at that time. Selecting "Disabled" places the output relays back in service. If the 469 measures phase current or control power is cycled, the FORCE OPERATION OF RELAYS setpoint will automatically become disabled and the output relays will revert back to their normal states. If any relay is forced, the 469 In Service LED will flash, indicating that the 469 is not in protection mode. 4.14.5 TEST ANALOG OUTPUT In addition to the simulation modes, the TEST ANALOG OUTPUT setpoint group may be used during startup or testing to verify that the analog outputs are functioning correctly. The analog outputs can only be forced if the motor is stopped and there are no trips, alarms, or start blocks active. When the FORCE ANALOG OUTPUTS FUNCTION is "Enabled", the output reflects the forced value as a percentage of the 4 to 20 mA or 0 to 1 mA range. Selecting "Disabled" places all four analog output channels back in service, reflecting the parameters programmed to each. If the 469 measures phase current or control power is cycled, the FORCE ANALOG OUTPUTS FUNCTION is automatically disabled and all analog outputs revert back to their normal state. Any time the analog outputs are forced, the 469 In Service LED will flash, indicating that the 469 S13 469 TESTING 4 4.14.6 COMM PORT MONITOR During the course of troubleshooting communications problems, it can be very useful to see the data that is first being transmitted to the 469 from some master device, and then see the data that the 469 transmits back to that master device. The messages shown here should make it possible to view that data. Any of the three communications ports may be monitored. After the communication buffers have been cleared, any data received from the communications port being monitored will be stored in the Rx1 and Rx2 buffers with ‘//’ acting as a character break between messages. If the 469 transmits a message, it will appear in the Tx1 and Tx2 buffers. In addition to these buffers, there is a message that will indicate the status Management Relay GE Power Management 4.15 S14 TWO-SPEED MOTOR 4 SETPOINT PROGRAMMING 4 4.15 S14 TWO-SPEED MOTOR 4.15.1 DESCRIPTION The two-speed motor feature provides proper protection for a two-speed motor where there will be two different full load values. The algorithm integrates the heating at each speed into one thermal model using a common thermal capacity used register value for both speeds. If the two-speed motor feature is used, ASSIGNABLE INPUT4 is dedicated as the two-speed motor monitor and terminals D22 and D23 are monitored for a contact closure. Closure of the contact signifies that the motor is in Speed 2. If the input is open, it signifies that the motor is in Speed 1. This allows the 469 to determine which setpoints should be active at any given point in time. SPEED2 MIN ALLOWABLE LINE VOLTAGE: 80% Range: 70 to 95%; Step: 1 Message seen only if Voltage Dependent Curve Style is selected SPEED2 ISTALL @ MIN Vline: 4.80 x FLA Range: 2.00 to 15.00 x FLA; Step: 0.01 Message seen only if Voltage Dependent Curve Style is selected SPEED2 SAFE STALL @ MIN Vline: 20.0 s Range: 0.5 to 999.9 sec; Step: 0.1 Message seen only if Voltage Dependent Curve Style is selected SPEED2 ACL INTERSECT @ MIN Vline: 3.80 x FLA Range: 2.00 to Istall@Min_Vline x FLA; Step: 0.01 Message seen only if Voltage Dependent Curve Style is selected SPEED2 4.15 S14 TWO-SPEED MOTOR 4 SETPOINT PROGRAMMING 4 All the Thermal Model parameters set for Speed 1 will be identical for Speed 2. A second overload curve setup may be programmed here for Speed 2, High Speed. 4.15.3 SPEED2 UNDERCURRENT The addition of a second Undercurrent trip or alarm level may be useful as it will indicate if the wrong setpoints are being used for the wrong speed i.e. normal running current for Speed 2 may be undercurrent for Speed for more BLOCK SPEED2 U/C FROM START: 0 s Range: 0 to 15000 s, step 1 SPEED2 U/C ALARM: Off Range: Off, Latched, Unlatched SPEED2 U/C ALARM PICKUP: 0.70 x FLA Range: 0.10 to 0.95 x FLA, step 0.01 SPEED2 U/C ALARM DELAY: 1 s Range: 1 to 60 sec., step 1 SPEED2 U/C ALARM EVENTS: Off Range: On, Off SPEED2 U/C TRIP: 0ff Range: Off, Latched, Unlatched SPEED2 U/C TRIP PICKUP: 0.70 x FLA Range: 0.10 4.15 S14 TWO-SPEED MOTOR 4 4.15.4 SPEED2 ACCELERATION Two additional acceleration timers are provided for the two speed motor feature. One timer is for a start in Speed 2 from a stopped condition. The other is an acceleration timer for the transition from Speed 1 to Speed 2. Also, while the motor is running, the 469 will ignore Mechanical Jam protection during the acceleration from Speed 1 to Speed 2 until the motor current has dropped below Speed 2 FLA × Overload Pickup value, or the Speed 1-2 acceleration time has expired. At that point in time, the Mechanical Jam feature will be enabled with the Speed 2 FLA ? s Range: 1.0 to 250.0 sec., step: 0.1 Seen only if one of the digital inputs is assigned as Speed Switch SPEED2 RATED SPEED: 3600 RPM Range: 100 to 7200 RPM; Step: 1 Seen only if one of the digital inputs is assigned as Measured values, maintenance and fault analysis information are accessed in Actual Value mode. Actual values may be accessed via one of the following methods: 1. The front panel, using the keys and display.