ICS TRIPLEX T8222處理器模塊
c光標(biāo)行復(fù)選框切換復(fù)選框以查看所需的圖形按鈕打印、幫助、保存(將值保存到文件)、打開(kāi)、放大、縮小光標(biāo)行要移動(dòng)行,請(qǐng)將鼠標(biāo)指針移動(dòng)到光標(biāo)行上。單擊并按住鼠標(biāo)左鍵并拖動(dòng)到新位置GE Power Management 469 Motor Management Relay 8-15 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3.9 PHASORS 469PC軟件可用于查看三相電流和電壓的相量圖。相量用于:?相電壓A、B和C?相電流A、B、C 1。469PC運(yùn)行并建立通信后,選擇“實(shí)際”>“計(jì)量數(shù)據(jù)”菜單項(xiàng),然后單擊“相量”選項(xiàng)卡,打開(kāi)“計(jì)量數(shù)據(jù)窗口”。將顯示相量圖、電壓相量值和電流相量值。較長(zhǎng)的箭頭表示電壓相量,較短的箭頭表示電流相量。Va和Ia是基準(zhǔn)(即零度相位)。滯后角為順時(shí)針。圖8–11:相量注釋電壓電平顯示電壓相量的值和角度電流相量短箭頭電壓相量長(zhǎng)箭頭電流電平顯示電流相量的數(shù)值和角度8-16 469電機(jī)管理繼電器GE電源管理8.3使用469PC 8 469 PC軟件8 8.3.10事件記錄469事件記錄器可以使用469PC軟件查看。事件記錄器在每次發(fā)生事件(例如,電機(jī)跳閘)時(shí)存儲(chǔ)電機(jī)和系統(tǒng)信息。最多可存儲(chǔ)40個(gè)事件,其中EVENT01是最新的,EVENT40是最舊的。每當(dāng)發(fā)生新事件時(shí),EVENT40都會(huì)被覆蓋。1.在469PC運(yùn)行并建立通信后,選擇“實(shí)際”>“事件記錄”菜單項(xiàng)以打開(kāi)“事件記錄窗口”。此窗口顯示事件列表,最新事件顯示在頂部(參見(jiàn)下圖)。2.按查看數(shù)據(jù)按鈕查看所選事件的詳細(xì)信息。3.視圖數(shù)據(jù)窗口頂部的事件記錄選擇器允許用戶滾動(dòng)瀏覽不同的事件。4.選擇“保存”將所選事件的詳細(xì)信息存儲(chǔ)到文件中。5.選擇“打印”將事件發(fā)送到系統(tǒng)打印機(jī),選擇“確定”關(guān)閉窗口。6.事件記錄器的更多信息可在“幫助”下找到。圖8–12:469PC事件記錄器顯示顯示上次事件的日期和自上次清除事件列表以來(lái)的事件總數(shù)最近顯示在頂部的事件列表查看數(shù)據(jù)單擊以顯示所選事件的詳細(xì)信息清除事件單擊清除事件按鈕以從內(nèi)存中清除事件列表事件選擇按鈕按下全部按鈕以選擇所有事件“無(wú)”按鈕可清除所有選擇GE Power Management 469 Motor Management Relay 8-17 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3.11 TROUBLESHOOTING(使用469PC 8故障排除)本節(jié)提供了在Windows環(huán)境中遇到故障(例如,通用保護(hù)故障(GPF)、丟失窗口、打開(kāi)/保存文件中的問(wèn)題、,和應(yīng)用程序錯(cuò)誤消息)。如果469PC軟件導(dǎo)致Windows系統(tǒng)錯(cuò)誤:1。檢查系統(tǒng)資源:?在Windows 95/98中,右鍵單擊“我的電腦”圖標(biāo),然后單擊“性能”選項(xiàng)卡。?在Windows 3.1/3.11中,選擇“幫助”
ursor line CHECK BOX Toggle the check box to view the desired graphs BUTTONS Print, Help, Save (save values to a file), Open, Zoom In, Zoom Out CURSOR LINES To move lines, move the mouse pointer over the cursor line. Click and hold the left mouse button and drag to a new location GE Power Management 469 Motor Management Relay 8-15 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3.9 PHASORS The 469PC software can be used to view the phasor diagram of three phase currents and voltages. The phasors are for: ? Phase Voltages A, B, and C ? Phase Currents A, B, and C 1. With 469PC running and the communications established, open the Metering Data window by selecting the Actual > Metering Data menu item then clicking the Phasors tab. The phasor diagram and the values of voltage phasors, and current phasors are displayed. Longer arrows are the voltage phasors, shorter arrows are the current phasors. 2. Va and Ia are the references (i.e. zero degree phase). The lagging angle is clockwise. Figure 8–11: PHASORS NOTE VOLTAGE LEVEL Displays the value and the angle of the voltage phasors CURRENT PHASOR Short arrow VOLTAGE PHASOR Long arrow CURRENT LEVEL Displays the value and angle of the current phasors 8-16 469 Motor Management Relay GE Power Management 8.3 USING 469PC 8 469 PC SOFTWARE 8 8.3.10 EVENT RECORDING The 469 event recorder can be viewed with the 469PC software. The event recorder stores motor and system information each time an event occurs (e.g. motor trip). Up to 40 events can be stored, where EVENT01 is the most recent and EVENT40 is the oldest. EVENT40 is overwritten whenever a new event occurs. 1. With 469PC running and communications established, select the Actual > Event Recording menu item to open the Event Recording window. This window displays the list of events with the most current event displayed on top (see the figure below). 2. Press the View Data button to view the details of selected events. 3. The Event Record Selector at the top of the View Data Window allows the user to scroll through different events. 4. Select Save to store the details of the selected events to a file. 5. Select Print to send the events to the system printer, and OK to close the window. 6. More information for the event recorder can be found under Help. Figure 8–12: 469PC EVENT RECORDER DISPLAY Displays the date of last event and the total number of events since last clear EVENT LISTING List of events with the most recent displayed on top VIEW DATA Click to display the details of selected events CLEAR EVENTS Click the Clear Events button to clear the Event Listing from memory EVENT SELECT BUTTONS Push the All button to select all events Push the None button to clear all selections GE Power Management 469 Motor Management Relay 8-17 8 469 PC SOFTWARE 8.3 USING 469PC 8 8.3.11 TROUBLESHOOTING This section provides some procedures for troubleshooting the 469PC when troubles are encountered within the Windows environment (for example, General Protection Fault (GPF), Missing Window, Problems in Opening/Saving Files, and Application Error messages). If the 469PC software causes Windows system errors: 1. Check system resources: ? In Windows 95/98, right-click on the My Computer icon and click on the Performance tab. ? In Windows 3.1/3.11, select the Help