ICS TRIPLEX T8200處理器模塊,DCS工控模塊備件
欠功率塊PF元件從開始1 s塊欠功率從開始0 s功率因數(shù)報(bào)警關(guān)閉欠功率報(bào)警關(guān)閉分配報(bào)警繼電器報(bào)警分配報(bào)警繼電器警報(bào)功率因數(shù)超前報(bào)警水平關(guān)閉欠功率警報(bào)水平2 kW功率因數(shù)滯后報(bào)警水平關(guān)閉低功率報(bào)警延遲1 s功率因數(shù)警報(bào)延遲1.0 s欠功率報(bào)警事件關(guān)閉功率因數(shù)報(bào)警事件關(guān)閉欠功率跳閘關(guān)閉功率因數(shù)跳閘關(guān)閉分配跳閘繼電器跳閘分配跳閘繼電器跳脫欠功率跳閘等級(jí)1 kW功率因數(shù)超前跳閘等級(jí)關(guān)閉欠功率跳閘延遲1 s功率因數(shù)滯后跳閘等級(jí)關(guān)閉反向功率因數(shù)跳閘延遲1.0 s阻止從啟動(dòng)開始的反向功率0 s無功功率反向功率警報(bào)關(guān)閉阻止從啟動(dòng)1 s分配報(bào)警繼電器警報(bào)無功功率警報(bào)關(guān)閉反向功率報(bào)警等級(jí)2 kW分配報(bào)警繼電器報(bào)警反向功率報(bào)警延遲1秒正kvar報(bào)警等級(jí)10 kvar反向功率報(bào)警事件關(guān)閉負(fù)kvar報(bào)警級(jí)別10 kvar反功率跳閘關(guān)閉無功功率報(bào)警延遲1.0 s分配跳閘繼電器跳閘無功功率警報(bào)事件關(guān)閉反向功率跳閘等級(jí)1 kW無功功率跳閘關(guān)閉反功率跳閘延遲1秒分配跳閘繼電器跳閘扭矩設(shè)置正kvar跳閘電平關(guān)閉扭矩計(jì)量禁用負(fù)kvar跳閘水平關(guān)閉定子電阻0.004? 跳閘延遲1.0 s極對(duì)2扭矩單位牛頓米超扭矩設(shè)置超扭矩警報(bào)關(guān)閉分配警報(bào)繼電器警報(bào)超扭矩警報(bào)級(jí)別4000.0 Nm超扭矩警報(bào)延遲1.0 s超扭矩警報(bào)事件關(guān)閉GE Power Management 469電機(jī)管理繼電器A-11附錄A A.1調(diào)試A表A–11:設(shè)置點(diǎn)第11頁–監(jiān)控描述默認(rèn)用戶值描述默認(rèn)用戶VALUE TRIP COUNTER kvar DEMAND跳閘計(jì)數(shù)器警報(bào)關(guān)閉kvar需求周期15分鐘分配報(bào)警繼電器警報(bào)kvar需求警報(bào)關(guān)閉跳閘計(jì)數(shù)器警報(bào)25跳閘分配報(bào)警繼電器報(bào)警事件關(guān)閉kvar請(qǐng)求單元100 kvar啟動(dòng)器故障kvar需求報(bào)警事件關(guān)閉啟動(dòng)器故障警報(bào)關(guān)閉kVA DEMAND啟動(dòng)器型斷路器kVA需求周期15 min。分配報(bào)警繼電器報(bào)警kVA需求報(bào)警關(guān)閉啟動(dòng)器故障延遲100 ms分配報(bào)警繼電器跳閘線圈報(bào)警監(jiān)控禁用kVA需求單元100 kVA報(bào)警事件關(guān)閉kVA需求報(bào)警事件關(guān)閉電流需求和脈沖輸出電流需求周期15分鐘。位置kWh脈沖輸出繼電器關(guān)閉電流需求報(bào)警關(guān)閉位置kWh脈沖輸入間隔1 kWh分配報(bào)警繼電器報(bào)警位置kvarh脈沖輸出。繼電器關(guān)閉電流需求限制100 A Pos.kvarh脈沖輸出。間隔1 kvarh報(bào)警事件關(guān)閉負(fù)極。kvarh脈沖輸出。繼電器關(guān)閉kW DEMAND負(fù)極。kvarh脈沖輸出。間隔1 kvarh kW需求周期15分鐘。運(yùn)行時(shí)間脈沖繼電器關(guān)閉kW需求報(bào)警關(guān)閉運(yùn)行時(shí)間脈沖間隔0秒分配報(bào)警繼電器報(bào)警kW需求限制100 kW報(bào)警事件關(guān)閉A-12 469電機(jī)管理繼電器GE電源管理A.1調(diào)試附錄A表A–12:設(shè)定值第12頁–模擬輸入/輸出描述默認(rèn)用戶值描述默認(rèn)用戶數(shù)值模擬輸出1模擬輸出3最小0%最小0°C最大限度
UNDERPOWER Block PF Element From Start 1 s Block Underpower From Start 0 s Power Factor Alarm Off Underpower Alarm Off Assign Alarm Relays Alarm Assign Alarm Relays Alarm Power Factor Lead Alarm Level Off Underpower Alarm Level 2 kW Power Factor Lag Alarm Level Off Underpower Alarm Delay 1 s Power Factor Alarm Delay 1.0 s Underpower Alarm Events Off Power Factor Alarm Events Off Underpower Trip Off Power Factor Trip Off Assign Trip Relays Trip Assign Trip Relays Trip Underpower Trip Level 1 kW Power Factor Lead Trip Level Off Underpower Trip Delay 1 s Power Factor Lag Trip Level Off REVERSE POWER Power Factor Trip Delay 1.0 s Block Reverse Power From Start 0 s REACTIVE POWER Reverse Power Alarm Off Block kvar Element From Start 1 s Assign Alarm Relays Alarm Reactive Power Alarm Off Reverse Power Alarm Level 2 kW Assign Alarm Relays Alarm Reverse Power Alarm Delay 1 s Positive kvar Alarm Level 10 kvar Reverse Power Alarm Events Off Negative kvar Alarm Level 10 kvar Reverse Power Trip Off Reactive Power Alarm Delay 1.0 s Assign Trip Relays Trip Reactive Power Alarm Events Off Reverse Power Trip Level 1 kW Reactive Power Trip Off Reverse Power Trip Delay 1 s Assign Trip Relays Trip TORQUE SETUP Positive kvar Trip Level Off Torque Metering Disabled Negative kvar Trip Level Off Stator Resistance 0.004 ? Trip Delay 1.0 s Pole Pairs 2 Torque Unit Newton-meter OVERTORQUE SETUP Overtorque Alarm Off Assign Alarm Relays Alarm Overtorque Alarm Level 4000.0 Nm Overtorque Alarm Delay 1.0 s Overtorque Alarm Events Off GE Power Management 469 Motor Management Relay A-11 APPENDIX A A.1 COMMISSIONING A Table A–11: SETPOINTS PAGE 11 – MONITORING DESCRIPTION DEFAULT USER VALUE DESCRIPTION DEFAULT USER VALUE TRIP COUNTER kvar DEMAND Trip Counter Alarm Off kvar Demand Period 15 min. Assign Alarm Relays Alarm kvar Demand Alarm Off Trip Counter Alarm 25 Trips Assign Alarm Relays Alarm Alarm Events Off kvar Demand Unit 100 kvar STARTER FAILURE kvar Demand Alarm Events Off Starter Failure Alarm Off kVA DEMAND Starter Type Breaker kVA Demand Period 15 min. Assign Alarm Relays Alarm kVA Demand Alarm Off Starter Failure Delay 100 ms Assign Alarm Relays Alarm Supervision Of Trip Coil Disabled kVA Demand Unit 100 kVA Alarm Events Off kVA Demand Alarm Events Off CURRENT DEMAND PULSE OUTPUT Current Demand Period 15 min. Pos. kWh Pulse Output Relay Off Current Demand Alarm Off Pos. kWh Pulse Output Interval 1 kWh Assign Alarm Relays Alarm Pos. kvarh Pulse Out. Relay Off Current Demand Limit 100 A Pos. kvarh Pulse Out. Interval 1 kvarh Alarm Events Off Neg. kvarh Pulse Out. Relay Off kW DEMAND Neg. kvarh Pulse Out. Interval 1 kvarh kW Demand Period 15 min. Running Time Pulse Relay Off kW Demand Alarm Off Running Time Pulse Interval 0 s Assign Alarm Relays Alarm kW Demand Limit 100 kW Alarm Events Off A-12 469 Motor Management Relay GE Power Management A.1 COMMISSIONING APPENDIX A A Table A–12: SETPOINTS PAGE 12 – ANALOG I/O DESCRIPTION DEFAULT USER VALUE DESCRIPTION DEFAULT USER VALUE ANALOG OUTPUT 1 ANALOG OUTPUT 3 Minimum 0% Minimum 0°C Maximum