ICS TRIPLEX T8110處理器模塊,DCS工控模塊備件
振動(dòng)、壓力、流量等輸入。圖1–2:保護(hù)特征故障診斷通過(guò)預(yù)處理數(shù)據(jù)、事件記錄、跟蹤存儲(chǔ)器和統(tǒng)計(jì)數(shù)據(jù)提供。在發(fā)出跳閘之前,469對(duì)測(cè)量參數(shù)進(jìn)行快照,并將其與跳閘原因一起存儲(chǔ)。在行程復(fù)位之前,可使用鍵查看行程前數(shù)據(jù),或訪問(wèn)A1 STATUS?LAST trip data(A1狀態(tài))實(shí)際值。469事件記錄器可存儲(chǔ)多達(dá)40個(gè)時(shí)間和日期戳事件,包括行車前數(shù)據(jù)。每次發(fā)生跳閘時(shí),469存儲(chǔ)所有測(cè)量的交流電量的跳閘前8個(gè)周期和跳閘后8個(gè)周期的軌跡。跳閘計(jì)數(shù)器記錄每種類型跳閘的發(fā)生次數(shù)。還記錄RTD和模擬輸入的最小值和最大值。這些功能使操作員能夠快速確定問(wèn)題。作為標(biāo)準(zhǔn)功能,469中包含功率計(jì)量。下表列出了通過(guò)前面板或通信端口可用的計(jì)量參數(shù)。51過(guò)載86過(guò)載鎖定66啟動(dòng)/小時(shí)和啟動(dòng)間隔時(shí)間重啟塊(防反沖計(jì)時(shí)器)50短路和短路備用機(jī)械堵塞37 32欠電流/欠功率反向功率46電流不平衡50G/51G接地故障和接地故障備用87差動(dòng)加速度49定子RTD 38軸承RTD其他RTD和環(huán)境RTD開(kāi)路RTD報(bào)警短路/低RTD 27/59欠壓/過(guò)壓47相位反轉(zhuǎn)81頻率無(wú)功功率55/78功率因數(shù)模擬輸入需求報(bào)警:A kW kvar kVA SR469自檢,維修跳閘線圈監(jiān)控焊接接觸器斷路器故障遠(yuǎn)程開(kāi)關(guān)14速度開(kāi)關(guān)和轉(zhuǎn)速表跳閘減載開(kāi)關(guān)壓力開(kāi)關(guān)振動(dòng)開(kāi)關(guān)19減壓?jiǎn)?dòng)48過(guò)轉(zhuǎn)矩遠(yuǎn)程啟動(dòng)/停止PROCTLA5.CDR不完整順序(減壓?jiǎn)?dòng))強(qiáng)制繼電器操作下一篇GE Multilin 469電機(jī)管理繼電器1-3 1簡(jiǎn)介1.1概述1 469已配備具有3個(gè)功能齊全且獨(dú)立的通信端口。前面板RS232端口可用于469設(shè)定點(diǎn)編程、本地詢問(wèn)或控制以及469固件的升級(jí)。計(jì)算機(jī)RS485端口可以連接到PLC、DCS或基于PC的用戶界面程序。輔助RS485端口可用于第二PLC、DCS或PC軟件的冗余或同時(shí)詢問(wèn)和/或控制。還有四個(gè)4至20 mA或0至1 mA(按訂單規(guī)定)傳感器輸出,可分配給任何測(cè)量參數(shù)。這些輸出的范圍是可擴(kuò)展的。下表列出了其他功能。1.1.2訂單信息所有469項(xiàng)功能均為標(biāo)準(zhǔn)功能;沒(méi)有選擇。訂購(gòu)時(shí)必須指定相位CT次級(jí)、控制功率和模擬輸出范圍。469個(gè)差分CT輸入可現(xiàn)場(chǎng)編程,用于1 A或5 A二次電流的CT。有兩個(gè)接地CT輸入,一個(gè)用于GE Power Management 50:0.025芯平衡CT,另一個(gè)用于具有1 a或5 a次級(jí)的接地CT,也可現(xiàn)場(chǎng)編程。VT輸入將以三角形或Y形配置容納VT。輸出繼電器始終是非故障安全的,服務(wù)繼電器除外。469PC軟件隨每個(gè)單元提供。input such as vibration, pressure, flow, etc. Figure 1–2: PROTECTION FEATURES Fault diagnostics are provided through pretrip data, event record, trace memory, and statistics. Prior to issuing a trip, the 469 takes a snapshot of the measured parameters and stores them with the cause of the trip. This pre-trip data may be viewed using the key before the trip is reset, or by accessing the A1 STATUS ?× LAST TRIP DATA actual values. The 469 event recorder stores up to 40 time and date stamped events including the pre-trip data. Each time a trip occurs, the 469 stores a trace of 8 cycles pre-trip and 8 cycles post-trip for all measured AC quantities. Trip counters record the number of occurrences of each type of trip. Minimum and maximum values for RTDs and analog inputs are also recorded. These features enable the operator to pinpoint a problem quickly and with certainty. Power metering included with the 469 as a standard feature. The table below outlines the metered parameters available either through the front panel or communications ports. 51 Overload 86 Overload Lockout 66 Starts/Hour & Time Between Starts Restart Block (Anti-Backspin Timer) 50 Short Circuit & Short Circuit Backup Mechanical Jam 37 32 Undercurrent/Underpower Reverse Power 46 Current Unbalance 50G/51G Ground Fault & Ground Fault Backup 87 Differential Acceleration 49 Stator RTD 38 Bearing RTD Other RTD & Ambient RTD Open RTD Alarm Short/Low RTD 27/59 Undervoltage/Overvoltage 47 Phase Reversal 81 Frequency Reactive Power 55/78 Power Factor Analog Input Demand Alarm: A kW kvar kVA SR469 Self-Test, Service Trip Coil Supervision Welded Contactor Breaker Failure Remote Switch 14 Speed Switch & Tachometer Trip Load Shed Switch Pressure Switch Vibration Switch 19 Reduced Voltage Start 48 Over Torque Remote Start/Stop PROCTLA5.CDR Incomplete Sequence (Reduced Voltage Start) Forced Relay Operation NEXT GE Multilin 469 Motor Management Relay 1-3 1 INTRODUCTION 1.1 OVERVIEW 1 The 469 is equipped with 3 fully functional and independent communications ports. The front panel RS232 port may be used for 469 setpoint programming, local interrogation or control, and upgrading of 469 firmware. The Computer RS485 port may be connected to a PLC, DCS, or PC based user interface program. The Auxiliary RS485 port may be used for redundancy or simultaneous interrogation and/or control from a second PLC, DCS, or PC software. There are also four 4 to 20 mA or 0 to 1 mA (as specified with order) transducer outputs that may be assigned to any measured parameter. The range of these outputs is scalable. Additional features are outlined in the table below. 1.1.2 ORDER INFORMATION All 469 features are standard; there are no options. The phase CT secondaries, control power, and analog output range must be specified at the time of order. The 469 differential CT inputs are field programmable for CTs with 1 A or 5 A secondaries. There are two ground CT inputs, one for the GE Power Management 50:0.025 core balance CT and one for a ground CT with a 1 A or 5 A secondary, also field programmable. The VT inputs will accommodate VTs in either a delta or wye configuration. The output relays are always non-failsafe with the exception of the service relay. The 469PC software is provided with each unit.