中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過低,為保證更佳的瀏覽體驗(yàn),請點(diǎn)擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設(shè)備有限公司網(wǎng)站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

ICS TRIPLEX T3160化模塊備件

ICS TRIPLEX T3160化模塊備件

ICS TRIPLEX T3160化模塊備件通過繼電器,將顯示此消息。4.單擊“確定”以編輯通信設(shè)置(或者隨時選擇“通信”>“計(jì)算機(jī)”菜單項(xiàng))。將出現(xiàn)“通信/計(jì)算機(jī)”對話框,其中包含本地PC的各種通信設(shè)置。應(yīng)按如下所示修改設(shè)置。圖3-3:通信/計(jì)算機(jī)對話框5。要開始通信,請單擊對話框通信部分中的ON按鈕。狀態(tài)部分指示通信狀態(tài)。如果建立了通信,將顯示消息“469PC現(xiàn)在正在與469通話”。此外...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

ICS TRIPLEX T3160化模塊備件

    ICS TRIPLEX T3160化模塊備件

    通過繼電器,將顯示此消息。4.單擊“確定”以編輯通信設(shè)置(或者隨時選擇“通信”>“計(jì)算機(jī)”菜單項(xiàng))。將出現(xiàn)“通信/計(jì)算機(jī)”對話框,其中包含本地PC的各種通信設(shè)置。應(yīng)按如下所示修改設(shè)置。圖3-3:通信/計(jì)算機(jī)對話框5。要開始通信,請單擊對話框通信部分中的ON按鈕。狀態(tài)部分指示通信狀態(tài)。如果建立了通信,將顯示消息“469PC現(xiàn)在正在與469通話”。此外,屏幕右下角的狀態(tài)指示“正在通信”?;谟脩羰走x項(xiàng)設(shè)置。在“與繼電器通信”模式下,469PC將嘗試在啟動后立即建立通信。當(dāng)處于“文件模式/默認(rèn)設(shè)置”時,469PC在嘗試通信之前等待用戶單擊“打開”按鈕–當(dāng)469PC在使用時沒有連接469繼電器時,首選此模式。啟動模式設(shè)置為與RS232/RS485轉(zhuǎn)換器類型匹配。如果通過469前面板RS232端口連接,請選擇“無控制類型”。如果通過GE Multilin F485轉(zhuǎn)換器單元連接,請選擇“Multilin RS232/RS485轉(zhuǎn)換器”。如果通過調(diào)制解調(diào)器連接,請選擇“調(diào)制解調(diào)器”。如果使用第三方RS232/RS485轉(zhuǎn)換器,請根據(jù)制造商的規(guī)范從可用列表中選擇適當(dāng)?shù)目刂祁愋???刂祁愋驮O(shè)置為與469 PARITY設(shè)置點(diǎn)匹配(參見S1 469 SETUP)。如果通過469前面板RS232端口連接,則設(shè)置為“無”。奇偶校驗(yàn)設(shè)置與469 BAUD RATE(波特率)設(shè)定值匹配(參見S1 469 SETUP(設(shè)置))。波特率設(shè)置為469繼電器連接的位置(例如COM1或COM2)。在大多數(shù)計(jì)算機(jī)上,COM1由鼠標(biāo)設(shè)備使用,因此COM2通常可用于通信。通信端口#本地PC上的COM端口設(shè)置為與469從屬地址設(shè)置點(diǎn)匹配(請參閱S1 469設(shè)置)。從屬地址3-8 469電機(jī)管理繼電器GE Multilin 3.2 469PC軟件接口3用戶界面3 3.2.4使用469PC a)將設(shè)定值保存到文件中在執(zhí)行任何固件升級之前,必須將設(shè)定值存儲到本地PC上的文件中。在進(jìn)行任何設(shè)定點(diǎn)更改或創(chuàng)建新的設(shè)定點(diǎn)文件之前,強(qiáng)烈建議保存設(shè)定點(diǎn)。要將設(shè)定值保存到本地PC上的文件中,請遵循以下步驟。1.選擇文件>屬性菜單項(xiàng)。出現(xiàn)下面的對話框,允許為469PC軟件配置正確的固件版本。469PC在創(chuàng)建設(shè)定點(diǎn)文件時需要知道正確的版本,以便特定版本中不可用的設(shè)定點(diǎn)不會下載到繼電器中。2.選擇正確的固件版本后,選擇文件>另存為菜單項(xiàng)。這將啟動以下對話框。在文件名框中輸入保存設(shè)定點(diǎn)的文件名,或選擇任何顯示的文件名來更新它們。

    with the relay, this message will appear. 4. Click OK to edit the communications settings (or alternately, select the Communications > Computer menu item at any time). The Communications/Computer dialog box will appear containing the various communications settings for the local PC. The settings should be modified as shown below. Figure 3–3: COMMUNICATION/COMPUTER DIALOG BOX 5. To begin communications, click the ON button in the Communication section of the dialog box. The status section indicates the communications status. If communications are established, the message “469PC is now talking to a 469” is displayed. As well, the status at the bottom right hand corner of the screen indicates “Communicating”. Set the based on user preference. In “Communicate with Relay” mode, 469PC will attempt to establish communications immediately upon startup. While in the “File mode /w default settings”, 469PC waits for the user to click the ON button before attempting communications – this mode is preferred when the 469PC is being used without an attached 469 relay. Startup Mode Set to match the type of RS232/RS485 converter. If connected through the 469 front panel RS232 port, select “No Control Type”. If connected through a GE Multilin F485 converter unit, select “MULTILIN RS232/RS485 CONVERTOR”. If connected through a modem, select “Modem”. If a thirdparty RS232/RS485 converter is being used, select the appropriate control type from the available list based on the manufacturer’s specifications. Control Type Set to match the 469 PARITY setpoint (see S1 469 SETUP). If connected through the 469 front panel RS232 port, set to “None”. Parity Set to match the 469 BAUD RATE setpoint (see S1 469 SETUP). Baud Rate Set to where the 469 relay is connected (e.g. COM1 or COM2). On most computers, COM1 is used by the mouse device and as such COM2 is usually available for communications. Communcation Port # the COM port on your local PC Set to match the 469 SLAVE ADDRESS setpoint (see S1 469 SETUP). Slave Address 3-8 469 Motor Management Relay GE Multilin 3.2 469PC SOFTWARE INTERFACE 3 USER INTERFACES 3 3.2.4 USING 469PC a) SAVING SETPOINTS TO A FILE Setpoints must be saved to a file on the local PC before performing any firmware upgrades. Saving setpoints is also highly recommended before making any setpoint changes or creating new setpoint files. To save setpoints to a file on the local PC, follow the procedure below. 1. Select the File > Properties menu item. The dialog box below appears, allowing for the configuration of the 469PC software for the correct firmware version. 469PC needs to know the correct version when creating a setpoint file so that setpoints not available in a particular version are not downloaded into the relay. 2. When the correct firmware version is chosen, select the File > Save As menu item. This launches the following dialog box. Enter the filename under which the setpoints are saved in the File Name box or select any displayed file names to update them.

    2022.12.31.jpg

    fa405aeea632aa6912154382925a28b_副本.jpg

    23.jpg

    3.jpg

    微信圖片_20211117105440.png


    ICS

    品牌:ICS TRIPLEX

    型號:  TRIPLEX T3160 

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號