ICS TRIPLEX T3120機(jī)械備件,工控模塊機(jī)器人備件
觸發(fā)圖形的光標(biāo)行1、2或差值(增量)值單擊以手動(dòng)觸發(fā)和捕獲波形DATE/TIME顯示觸發(fā)原因觸發(fā)原因的日期和時(shí)間WAVEFORM繼電器波形數(shù)據(jù)LEVEL在實(shí)線光標(biāo)行顯示圖形的值CHECK BOX切換復(fù)選框以查看所需的圖形按鈕打印、幫助、,保存(將圖形保存到文件)、打開(打開圖形文件)、放大和縮小光標(biāo)行要移動(dòng)行,請(qǐng)將鼠標(biāo)指針移動(dòng)到光標(biāo)行上;按住鼠標(biāo)左鍵并將光標(biāo)線拖動(dòng)到新位置GE Multilin 469電機(jī)管理繼電器3-15 3用戶接口3.2 469PC軟件接口3 3.2.7相量469PC軟件可用于查看三相電流和電壓的相量圖。相量用于:相電壓A、B和C;相電流A、B和C1。469PC運(yùn)行并建立通信后,選擇“實(shí)際”>“計(jì)量數(shù)據(jù)”菜單項(xiàng),然后單擊“相量”選項(xiàng)卡,打開“計(jì)量數(shù)據(jù)窗口”。將顯示相量圖、電壓相量值和電流相量值。較長(zhǎng)的箭頭表示電壓相量,較短的箭頭表示電流相量。Va和Ia是基準(zhǔn)(即零度相位)。滯后角為順時(shí)針。圖3-11:PHASORS 3.2.8事件記錄469事件記錄器可通過469PC軟件查看。事件記錄器在每次發(fā)生事件(例如,電機(jī)跳閘)時(shí)存儲(chǔ)電機(jī)和系統(tǒng)信息。最多可存儲(chǔ)40個(gè)事件,其中EVENT01是最新的,EVENT40是最舊的。每當(dāng)發(fā)生新事件時(shí),EVENT40都會(huì)被覆蓋。1.在469PC運(yùn)行并建立通信后,選擇“實(shí)際”>“事件記錄”菜單項(xiàng)以打開“事件記錄窗口”。此窗口顯示事件列表,最新事件顯示在頂部(參見下圖)。2.按查看數(shù)據(jù)按鈕查看所選事件的詳細(xì)信息。3.視圖數(shù)據(jù)窗口頂部的事件記錄選擇器允許用戶滾動(dòng)瀏覽不同的事件。4.選擇“保存”將所選事件的詳細(xì)信息存儲(chǔ)到文件中。5.選擇“打印”將事件發(fā)送到系統(tǒng)打印機(jī),選擇“確定”關(guān)閉窗口。事件記錄器的更多信息可在“幫助”下找到。注釋808713A1.CDR電壓電平顯示電壓相量值和角度電流相量短箭頭電壓相量長(zhǎng)箭頭電流電平顯示電流相量值值和角度3-16 469電機(jī)管理繼電器GE Multilin 3.2 469PC軟件接口3用戶界面3圖3–12:469PC事件記錄器3.2.9故障排除本節(jié)提供了一些程序在Windows環(huán)境中遇到故障時(shí)(例如,通用保護(hù)故障(GPF)、丟失窗口、打開/保存文件中的問題和應(yīng)用程序錯(cuò)誤消息),對(duì)469PC進(jìn)行故障排除。如果469PC軟件導(dǎo)致Windows系統(tǒng)錯(cuò)誤:1。檢查系統(tǒng)資源:?在Windows 95/98中,右鍵單擊“我的電腦”圖標(biāo),然后單擊“性能”選項(xiàng)卡。
Cursor Lines 1, 2, or Difference (Delta) values for the graph TRIGGER Click to manually trigger and capture waveforms DATE/TIME Displays the date and time of the trigger cause TRIGGER CAUSE Displays the cause of the trigger WAVEFORM The relay waveform data LEVEL Displays the value of the graph at the solid cursor line CHECK BOX Toggle the check boxes to view desired graphs BUTTONS Print, Help, Save (to save graph to a file), Open (to open a graph file), Zoom In and Out CURSOR LINES To move lines, move the mouse pointer over the cursor line; hold the left mouse button and drag the cursor line to a new location GE Multilin 469 Motor Management Relay 3-15 3 USER INTERFACES 3.2 469PC SOFTWARE INTERFACE 3 3.2.7 PHASORS The 469PC software can be used to view the phasor diagram of three phase currents and voltages. The phasors are for: Phase Voltages A, B, and C; Phase Currents A, B, and C. 1. With 469PC running and the communications established, open the Metering Data window by selecting the Actual > Metering Data menu item then clicking the Phasors tab. The phasor diagram and the values of voltage phasors, and current phasors are displayed. Longer arrows are the voltage phasors, shorter arrows are the current phasors. 2. Va and Ia are the references (i.e. zero degree phase). The lagging angle is clockwise. Figure 3–11: PHASORS 3.2.8 EVENT RECORDS The 469 event recorder can be viewed with the 469PC software. The event recorder stores motor and system information each time an event occurs (e.g. motor trip). Up to 40 events can be stored, where EVENT01 is the most recent and EVENT40 is the oldest. EVENT40 is overwritten whenever a new event occurs. 1. With 469PC running and communications established, select the Actual > Event Recording menu item to open the Event Recording window. This window displays the list of events with the most current event displayed on top (see the figure below). 2. Press the View Data button to view the details of selected events. 3. The Event Record Selector at the top of the View Data Window allows the user to scroll through different events. 4. Select Save to store the details of the selected events to a file. 5. Select Print to send the events to the system printer, and OK to close the window. More information for the event recorder can be found under Help. NOTE 808713A1.CDR VOLTAGE LEVEL Displays the value and the angle of the voltage phasors CURRENT PHASOR Short arrow VOLTAGE PHASOR Long arrow CURRENT LEVEL Displays the value and angle of the current phasors 3-16 469 Motor Management Relay GE Multilin 3.2 469PC SOFTWARE INTERFACE 3 USER INTERFACES 3 Figure 3–12: 469PC EVENT RECORDER 3.2.9 TROUBLESHOOTING This section provides some procedures for troubleshooting the 469PC when troubles are encountered within the Windows environment (for example, General Protection Fault (GPF), Missing Window, Problems in Opening/Saving Files, and Application Error messages). If the 469PC software causes Windows system errors: 1. Check system resources: ?In Windows 95/98, right-click on the My Computer icon and click on the Performance tab.