中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗(yàn),請(qǐng)點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪問(wèn)瑞昌明盛自動(dòng)化設(shè)備有限公司網(wǎng)站!

圖片名

全國(guó)訂購(gòu)熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

HIMA F8620/4處理器模塊,備件模塊

HIMA F8620/4處理器模塊,備件模塊

HIMA F8620/4處理器模塊,備件模塊§將敏感輸入電線遠(yuǎn)離電氣噪聲電線,如離散輸出和交流電線。這可以通過(guò)將I/O模塊分組以保持輸出模塊與敏感輸入模塊分離來(lái)實(shí)現(xiàn)?!烀總€(gè)RX3i背板的四個(gè)側(cè)面都需要10 cm(4英寸)的間隙空間,用于通風(fēng)/冷卻?!霷X3i背板出于熱考慮而設(shè)計(jì)為水平安裝。其他安裝方向1 10 9 8 7 6 5 2 11 1。RX3i 2。電線槽(電線槽)3?,F(xiàn)場(chǎng)設(shè)備連接端子塊4...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

HIMA F8620/4處理器模塊,備件模塊

    HIMA F8620/4處理器模塊,備件模塊

    §將敏感輸入電線遠(yuǎn)離電氣噪聲電線,如離散輸出和交流電線。這可以通過(guò)將I/O模塊分組以保持輸出模塊與敏感輸入模塊分離來(lái)實(shí)現(xiàn)。§每個(gè)RX3i背板的四個(gè)側(cè)面都需要10 cm(4英寸)的間隙空間,用于通風(fēng)/冷卻?!霷X3i背板出于熱考慮而設(shè)計(jì)為水平安裝。其他安裝方向1 10 9 8 7 6 5 2 11 1。RX3i 2。電線槽(電線槽)3?,F(xiàn)場(chǎng)設(shè)備連接端子塊4。電機(jī)連接端子排5。電機(jī)起動(dòng)器6。電路板7。電源8??刂谱儔浩???扇蹟鄶嗦菲骰驍嗦菲?0??刂评^電器11。受保護(hù)外殼3 4圖8:系統(tǒng)布局指南PACSystems*RX3i系統(tǒng)手冊(cè)第3節(jié)GFK-2314T 2019年9月安裝21可能會(huì)影響系統(tǒng)性能、可靠性和機(jī)構(gòu)批準(zhǔn),因此不建議安裝?!鞂?duì)于所有模擬模塊,包括RTD和熱電偶模塊,使用屏蔽電纜連接,屏蔽一端接地(源極)。? 2.3外殼RX3i系統(tǒng)及其組件被視為開(kāi)放式設(shè)備[具有用戶可能接觸到的帶電電氣部件],必須安裝在保護(hù)外殼中,或安裝在為提供安全而制造的其他組件中。外殼或組件至少應(yīng)提供一定程度的保護(hù),以防12mm以下的固體物體(例如手指)。這相當(dāng)于NEMA/UL 1型外殼或IP20等級(jí)(IEC60529),提供至少2級(jí)污染環(huán)境。當(dāng)RX3i系統(tǒng)安裝在指定為危險(xiǎn)區(qū)域的區(qū)域時(shí),外殼必須是只能使用工具接近的外殼。有關(guān)特定產(chǎn)品認(rèn)證、危險(xiǎn)區(qū)域認(rèn)證類(lèi)型、危險(xiǎn)區(qū)域警告和ATEX附加外殼要求的參考,請(qǐng)參閱附錄A。外殼必須能夠充分消散安裝在內(nèi)部的所有組件產(chǎn)生的熱量,以防止組件過(guò)熱。散熱也是決定是否需要風(fēng)扇和空調(diào)等外殼冷卻選項(xiàng)的一個(gè)因素。RX3i背板的所有側(cè)面需要至少102mm(4英寸)的最小空間用于冷卻。可能需要額外的空間,這取決于設(shè)備在運(yùn)行過(guò)程中產(chǎn)生的熱量,或取決于其他PACSystems*RX3i系統(tǒng)手冊(cè)第3節(jié)GFK-2314T 2019年9月安裝22的要求,如系統(tǒng)布線的最小彎曲半徑。附錄B說(shuō)明了如何計(jì)算機(jī)柜中RX3i模塊和現(xiàn)場(chǎng)設(shè)備的散熱。2.3.1 RX3i通用背板尺寸和間距*允許冷卻通用背板前視圖側(cè)面尺寸適用于門(mén)關(guān)閉的標(biāo)準(zhǔn)模塊。側(cè)面尺寸不包括電纜和連接器所需的額外深度。帶有擴(kuò)展高密度接線板(如接線板IC694TBB132)的模塊整體深約?英寸(13mm)。圖9:RX3i通用背板尺寸和間距PACSystems*RX3i系統(tǒng)手冊(cè)第3節(jié)GFK-2314T 2019年9月安裝23 12插槽RX3i專(zhuān)用背板的安裝孔與10插槽Series 90-30背板完全匹配,便于升級(jí)。背板必須水平安裝,如上所述,通過(guò)在模塊周?chē)峁┳銐虻臍饬?,以滿足產(chǎn)品性能和可靠性規(guī)范。其他安裝方向可能會(huì)影響系統(tǒng)性能、可靠性和機(jī)構(gòu)批準(zhǔn),因此不建議使用。圖10:不建議垂直安裝2.3.2 RX3i串行擴(kuò)展背板尺寸和間距每個(gè)背板都有用于安裝在電氣面板上的標(biāo)準(zhǔn)連接法蘭。PACSystems*RX3i系統(tǒng)手冊(cè)第3節(jié)GFK-2314T 2019年9月安裝24*冷卻余量5插槽265mm(10.43英寸)10插槽433mm(17.44英寸)5插槽250mm(9.84英寸)10槽428mm(16.85英寸)102mm*。典型的擴(kuò)展背板正面圖安裝模塊的擴(kuò)展背板側(cè)面圖142mm(5.59in)側(cè)面尺寸適用于門(mén)關(guān)閉的模塊。側(cè)面尺寸不包括

    § Route sensitive input wires away from electrically-noisy wires such as discrete output and AC wiring. This can be facilitated by grouping I/O modules to keep output modules separated from sensitive input modules. § Clearance space of 10 cm (4 in) on all four sides of each RX3i backplane for ventilation/cooling is required. § RX3i backplanes are designed to be mounted horizontally due to thermal considerations. Other mounting orientations 1 10 9 8 7 6 5 2 11 1. RX3i 2. Wireway (Wire Duct) 3. Field device connection terminal block 4. Motor connection terminal block 5. Motor starters 6. Circuit board 7. Power supply 8. Control transformer 9. Fusible disconnect or circuit breaker 10. Control relays 11. Protected enclosure 3 4 Figure 8: System Layout Guidelines PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 21 may affect system performance, reliability, and agency approvals, and are therefore not recommended. § Use shielded cable connections with the shield grounded at one end (at source) for all analog modules, including RTD and Thermocouple modules. ? 2.3 Enclosures The RX3i system and its components are considered open equipment [having live electrical parts that may be accessible to users] and must be installed in a protective enclosure or incorporated into other assemblies manufactured to provide safety. At a minimum, the enclosure or assemblies shall provide a degree of protection against solid objects up to 12mm (e.g. fingers). This equates to a NEMA/UL Type 1 enclosure or an IP20 rating (IEC60529) providing at least a pollution degree 2 environment. When an RX3i system is installed into an area designated as a Hazardous Area, then the enclosure must be one that is only accessible by use of a tool. Refer to Appendix A for reference to specific product certifications, types of Hazardous Area approvals, Hazardous Area warnings, and additional enclosure requirements with respect to ATEX. The enclosure must be able to adequately dissipate the heat generated by all of the components mounted inside so that no components overheat. Heat dissipation is also a factor in determining the need for enclosure cooling options such as fans and air conditioning. A minimum space of at least 102 mm (4 in) is required on all sides of the RX3i backplane for cooling. Additional space may be required, depending on the amount of heat generated by the equipment during operation, or on other PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 22 requirements such as minimum bend radius for system cabling. Appendix B explains how to calculate heat dissipation for RX3i modules and field devices in an enclosure. 2.3.1 RX3i Universal Backplane Dimensions and Spacing * Allowance for cooling Universal Backplane front view Side dimension is for standard modules with doors closed. Side dimension does not include extra depth required for cables and connectors. Modules with Extended High-Density Terminal Blocks (such as Terminal Block IC694TBB132) are approximately ?-inch (13mm) deeper overall. Figure 9: RX3i Universal Backplane Dimensions and Spacing PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 23 The mounting holes for the 12-slot RX3i Universal Backplane match the 10-slot Series 90-30 Backplane exactly, for easy upgrades. Backplanes must be mounted horizontally, as represented above, to meet product performance and reliability specifications by providing adequate airflow around the modules. Other mounting orientations may affect system performance, reliability and agency approvals, and are therefore not recommended. Figure 10: Vertical Mounting Not Recommended 2.3.2 RX3i Serial Expansion Backplane Dimensions and Spacing Each backplane has standard attachment flanges for mounting on an electrical panel. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 24 * Allowance for cooling 5-Slot 265mm (10.43in) 10-Slot 433mm (17.44in) 5-Slot 250mm (9.84in) 10-Slot 428mm (16.85in) 102mm * (4.00in) 102mm * (4.00in) 102mm * (4.00in) 90mm (3.54in) 20mm (0.79in) 130mm (5.12in) 102mm * (4.00in) 5.08mm 0.20 dia. typical Expansion Backplane front view Expansion Backplane with modules installed side view 142mm (5.59in) Side dimension is for modules with doors closed. Side dimension does not include extra depth required for

    PHARPS32200000.jpg

    GE VMIVME-7698-345 350-017698-345 B.jpg

    FOXBORO H92A0K9V0H00.jpg

    23.jpg

    21.jpg

    20.jpg



    品牌: HIMA

    型號(hào):  F8620/4 

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號(hào)