中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過低,為保證更佳的瀏覽體驗(yàn),請點(diǎn)擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設(shè)備有限公司網(wǎng)站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

HIMA F3406a備件模塊

HIMA F3406a備件模塊

HIMA F3406a備件模塊是否圖49:電源輸入端子的正確接線規(guī)程? 對于IC694電源,每個(gè)端子接受一根AWG#14(2.1mm2)或兩根AWG#16(1.3mm2)75C(167F)銅線。電源端子的建議扭矩為1.36 Nm(12 in-lb)。每個(gè)端子都可以接受實(shí)心或絞合導(dǎo)線。同一端子中的多條電線應(yīng)具有相同的類型(實(shí)心或絞合)和尺寸。圖50:I/O模塊+/L1-/N/L2跳線接地的IC695...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

HIMA F3406a備件模塊

    HIMA F3406a備件模塊

    是否圖49:電源輸入端子的正確接線規(guī)程? 對于IC694電源,每個(gè)端子接受一根AWG#14(2.1mm2)或兩根AWG#16(1.3mm2)75°C(167°F)銅線。電源端子的建議扭矩為1.36 Nm(12 in-lb)。每個(gè)端子都可以接受實(shí)心或絞合導(dǎo)線。同一端子中的多條電線應(yīng)具有相同的類型(實(shí)心或絞合)和尺寸。圖50:I/O模塊+/L1-/N/L2跳線接地的IC695電源端子24VDC輸出圖51:IC694電源端子§僅用于擴(kuò)展(IC694)電源,底部端子可訪問擴(kuò)展背板的隔離+24V DC輸出,該輸出可用于為某些IC694模塊的輸入電路供電。有關(guān)信息,請參閱第4.2節(jié)模塊負(fù)載要求表。PACSystems*RX3i系統(tǒng)手冊第3節(jié)GFK-2314T 2019年9月安裝66注意事項(xiàng)如果隔離24Vdc電源過載或短路,PLC將停止運(yùn)行。PACSystems*RX3i系統(tǒng)手冊第3節(jié)GFK-2314T 2019年9月安裝67 2.6.6.2交流電源連接將火線和中性線或L1和L2連接到適當(dāng)?shù)碾娫炊俗印?.6.6.3直流電源連接所有RX3i電源都具有直流輸入功能。將直流電源的+和-導(dǎo)線連接到適當(dāng)?shù)亩俗印_@些連接是極性敏感的直流電源。2.6.6.3.1接地連接將安全接地線連接到標(biāo)有接地符號的端子。2.6.6.4外部過電壓保護(hù)電源模塊上的接地和MOV端子通常通過用戶安裝的跳線連接到機(jī)架接地(如圖52所示)。如果不需要過電壓保護(hù)或在上游提供過電壓保護(hù),則不需要跳線。在具有浮動中性輸入的系統(tǒng)中(中性線未參考保護(hù)接地),不得安裝此跳線。此外,在浮動中性點(diǎn)系統(tǒng)中,電壓浪涌保護(hù)裝置(如MOV)必須從L1安裝到接地,從L2(中性點(diǎn))安裝到接地線。+/L1-/N/L2跳線帶將過電壓保護(hù)裝置連接至機(jī)架接地機(jī)架接地螺釘端子圖52:外部過電壓保護(hù)2.6.6.5浮動中性點(diǎn)(IT)系統(tǒng)的交流電源連接如果在中性線未參考保護(hù)接地的系統(tǒng)中安裝交流輸入電源,必須遵循特殊的安裝說明,以防止損壞電源。浮動中性點(diǎn)系統(tǒng)是一種配電布線系統(tǒng),其中中性點(diǎn)和保護(hù)接地不通過可忽略的阻抗連接在一起。在歐洲,這被稱為IT系統(tǒng)(參考IEC950)。在浮動中性點(diǎn)系統(tǒng)中,從輸入端子到保護(hù)接地測量的電壓可能超過264Vac最大輸入電壓電源規(guī)格。L1 N PE圖53:浮動中性點(diǎn)PACSystems*RX3i系統(tǒng)手冊第3節(jié)GFK-2314T 2019年9月安裝68 2.6.6.6非浮動中性點(diǎn)系統(tǒng)系統(tǒng)的交流電源連接,其中配電線路的一條腿連接到保護(hù)接地,或配電線路的兩條腿之間的抽頭連接到保護(hù)地。非浮動中性系統(tǒng)。非浮動中性系統(tǒng)不需要特殊的安裝程序。圖54:中性點(diǎn)不浮動(接地)2.6.6.7浮動中性點(diǎn)系統(tǒng)說明1。輸入電源端子的接線應(yīng)如上圖49至圖51所示。2.不得在電源模塊的端子3和4之間安裝跳線。3.必須安裝電壓浪涌保護(hù)裝置,如MOV:? 從L1到接地? 從L2(中性點(diǎn))到接地電壓浪涌裝置的額定值必須確保系統(tǒng)免受超過線路電壓+100 Vac+(N-PE)MAX的電力線瞬變的影響。N-PE表示中性點(diǎn)和保護(hù)接地(PE)之間的電壓電勢。例如,在中性點(diǎn)浮動的240伏交流系統(tǒng)中

    Yes No Figure 49: Correct Wiring Practice for Power Supply Input Terminals ? For IC694 Power Supplies, each terminal accepts one AWG #14 (2.1mm2 ) or two AWG #16 (1.3mm2 ) copper 75°C (167°F) wires. The suggested torque for the Power Supply terminals is 1.36 Nm (12 in-lb). Each terminal can accept solid or stranded wires. Multiple wires in the same terminal should be of the same type (solid or stranded) and size. Figure 50: IC695 Power Supply Terminals 24VDC Output for I/O Modules + / L1 - / N / L2 Jumper Ground Figure 51: IC694 Power Supply Terminals § For Expansion (IC694) Power Supplies only, the bottom terminals provide access to the Isolated +24Vdc output of the Expansion Backplane, which can be used to power input circuits for certain IC694 modules. Refer to the table Module Load Requirements, Section 4.2 for information. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 66 CAUTION If the Isolated 24Vdc supply is overloaded or shorted, the PLC will stop operation. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 67 2.6.6.2 AC Power Source Connections Connect the hot and neutral wires or lines L1 and L2 to the appropriate Power Supply terminals. 2.6.6.3 DC Power Source Connections All RX3i Power Supplies have DC input capabilities. Connect the + and - wires from the DC source to the appropriate terminals. These connections are polarity-sensitive DC-only supplies. 2.6.6.3.1 Ground Connection Connect the safety ground wire to the terminal marked with a ground symbol. 2.6.6.4 External Overvoltage Protection The Ground and MOV terminals on a Power Supply module are normally connected to frame ground with a user-installed jumper (as shown in Figure 52). If overvoltage protection is not required or is supplied upstream, no jumper is needed. In systems with a floating neutral input (the neutral line is not referenced to Protective Earth Ground), this jumper must NOT be installed. In addition, in a floating neutral system, voltage surge protection devices such as MOVs must be installed from L1 to earth ground, and from L2 (Neutral) to earth ground. + / L1 - / N / L2 Jumper strap connects overvoltage protection devices to frame ground Frame Ground Screw Terminals Figure 52: External Overvoltage Protection 2.6.6.5 AC Power Supply Connections for Floating Neutral (IT) Systems If an AC input power supply is installed in a system where the Neutral line is not referenced to Protective Earth Ground, special installation instructions must be followed to prevent damage to the power supply. A Floating Neutral System is a system of power distribution wiring where Neutral and Protective Earth Ground are not tied together by negligible impedance. In Europe, this is referred to as an IT system (refer to IEC950). In a Floating Neutral System, voltages measured from input terminals to protective earth ground may exceed the 264Vac maximum input voltage power supply specification. L1 N PE Figure 53: Floating Neutral PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 68 2.6.6.6 AC Power Supply Connections for Non-Floating Neutral System Systems where one leg of the power distribution wiring is tied to Protective Earth or a tap between two legs of the power distribution wiring is tied to Protective Earth are not Floating Neutral Systems. Non-floating neutral systems do not require special installation procedures. Figure 54: Neutral Not Floating (Tied to Ground) 2.6.6.7 Instructions for Floating Neutral Systems 1. The input power terminals should be wired as shown in Figure 49 through Figure 51 above. 2. No jumper may be installed jumper between terminals 3 and 4 of the Power Supply module. 3. Voltage surge protection devices such as MOVs must be installed: ? From L1 to earth ground ? From L2 (Neutral) to earth ground The voltage surge devices must be rated such that the system is protected from power line transients that exceed Line voltage + 100 Vac + (N-PE)MAX. The expression N-PE refers to the voltage potential between neutral and Protective Earth (PE) ground. For example, in a 240 Volt AC system with neutral floating

    2022.12.15.jpg

    2022.11.29.jpg

    fa405aeea632aa6912154382925a28b_副本.jpg

    手機(jī)輪播圖2(1)_副本.jpg



    品牌: HIMA

    型號:  HIMA F3406a 

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號