HIMA F3226自動(dòng)化模塊備件
f對于4至20 mA增強(qiáng)范圍內(nèi)的所有輸入? 每個(gè)通道可配置的縮放和偏移? 每個(gè)通道可選擇高報(bào)警、低報(bào)警、高高報(bào)警、低低報(bào)警檢測和報(bào)告? 模塊故障報(bào)告? 支持邏輯程序中的診斷點(diǎn)故障觸點(diǎn)? 正負(fù)變化率報(bào)警? 在編程軟件中顯示模塊序列號、版本和日期代碼。? 模塊支持插入和取出通電的RX3i通用背板。參見第2.6.4.1節(jié)熱插拔。? 模塊支持使用WinLoader軟件實(shí)用程序(如果主機(jī)CPU具有串行端口)或使用基于Web的工具(如果主機(jī)沒有串行端口)進(jìn)行固件升級。固件升級套件中包含說明。23 9.9.3 LED:ALG233 MODULE OK LED提供模塊狀態(tài)信息,如下:ON:狀態(tài)正常,模塊已配置;PACSystems*RX3i系統(tǒng)手冊第10節(jié)GFK-2314T 2019年9月模擬輸入模塊397關(guān)閉:無背板電源或軟件未運(yùn)行(看門狗計(jì)時(shí)器超時(shí));持續(xù)快速閃爍:未從CPU接收到配置數(shù)據(jù);緩慢閃爍,然后熄滅:通電診斷失敗或遇到代碼執(zhí)行錯(cuò)誤。用戶電源LED指示外部24Vdc電源在規(guī)格范圍內(nèi)。9.9.4規(guī)格:ALG233信道數(shù)1至16可選;(單端信道)從DC到1kHz輸入阻抗250W輸入低通濾波器響應(yīng)23 Hz外部電源電壓范圍20到30 Vdc 56的交叉信道抑制>70dB在存在嚴(yán)重輻射射頻干擾(IEC 61000-4-3,10V/m)的情況下,精度可能會(huì)降低到滿量程的±5%。57在存在嚴(yán)重傳導(dǎo)射頻干擾(IEC 61000-4-6,10Vrms)的情況下,精度可能會(huì)降低到滿量程的±0.5%。PACSystems*RX3i系統(tǒng)手冊第10節(jié)GFK-2314T 2019年9月模擬輸入模塊398外部電源電壓紋波10%功耗120 mA來自背板上的+5Vdc總線來自24Vdc外部用戶電源65 mA(除了電流回路電流)對于產(chǎn)品標(biāo)準(zhǔn)和一般規(guī)范,參考附錄A.9.9.5配置:ALG233 9.9.5.1模塊設(shè)置:ALG23參數(shù)選擇描述活動(dòng)信道1至16要掃描的信道數(shù)量。通道按連續(xù)順序掃描。通道值參考模塊。通道值參考長度只讀取決于活動(dòng)通道的數(shù)量。每個(gè)通道提供兩個(gè)字的模擬輸入數(shù)據(jù)。啟用診斷報(bào)告級別。診斷參考長度只讀通道診斷數(shù)據(jù)所需的內(nèi)存量。啟用模塊級診斷報(bào)告時(shí),模塊中的32位診斷信息。模塊狀態(tài)參考長度0,32報(bào)告給CPU的模塊狀態(tài)位數(shù)。數(shù)據(jù)格式如下圖所示。58注意:要支持此功能,應(yīng)在Machine Edition中啟用Variable Mode屬性。PACSystems*RX3i系統(tǒng)手冊第10節(jié)GFK-2314T 2019年9月模擬輸入模塊399當(dāng)設(shè)置為0時(shí),狀態(tài)報(bào)告被禁用。要啟用狀態(tài)報(bào)告,請將此參數(shù)設(shè)置為0以外的值。I/O掃描集1至32將模塊I/O狀態(tài)數(shù)據(jù)分配給CPU配置中定義的掃描集。確定RX3i輪詢數(shù)據(jù)輸入默認(rèn)強(qiáng)制關(guān)閉(默認(rèn))或保持最后狀態(tài)的頻率。如果模塊發(fā)生故障或移除,此參數(shù)指定模塊所有通道值參考的狀態(tài)。強(qiáng)制關(guān)閉=通道值清除為0。保持最后狀態(tài)=頻道保持其最后狀態(tài)。
or all inputs in 4 to 20 mA Enhanced Range ? Configurable scaling and offsets per channel ? High alarm, low alarm, high-high alarm, low-low alarm detection and reporting selectable per channel ? Module fault reporting ? Supports diagnostic point fault contacts in the logic program ? Positive and negative Rate of Change Alarms ? Display of module serial number, revision and date code in programming software. ? Module supports insertion into and removal from an RX3i Universal Backplane which is under power. Refer to Hot Insertion and Removal, Section 2.6.4.1. ? Module supports firmware upgrades using the WinLoader software utility (if the host CPU has a serial port) or using a Web-based tool (if the host CPU has no serial port). Instructions are included with the firmware upgrade kit.23 9.9.3 LEDs: ALG233 The MODULE OK LED provides module status information as follows: ON: status is OK, module configured; PACSystems* RX3i System Manual Section 10 GFK-2314T Sept. 2019 Analog Input Modules 397 OFF: no backplane power or software not running (watchdog timer timed out); Continuous rapid blinking: configuration data not received from CPU; Slow blinking, then OFF: failed power-up diagnostics or encountered code execution error. The USER SUPPLY LED indicates that the external 24Vdc supply is within specifications. 9.9.4 Specifications: ALG233 Number of Channels 1 to 16 selectable; (single-ended channels) Cross-Channel Rejection > 70dB from DC to 1kHz Input Impedance 250W Input Low Pass Filter Response 23 Hz External Supply Voltage Range 20 to 30 Vdc 56 In the presence of severe Radiated RF interference (IEC 61000-4-3, 10V/m), accuracy may be degraded to ±5% of full scale. 57 In the presence of severe Conducted RF interference (IEC 61000-4-6, 10Vrms), accuracy may be degraded to ±0.5% of full scale. PACSystems* RX3i System Manual Section 10 GFK-2314T Sept. 2019 Analog Input Modules 398 External Supply Voltage Ripple 10% Power Consumption 120 mA from the +5Vdc bus on the backplane 65 mA from 24Vdc external user power supply (in addition to current loop currents) For product standards and general specifications, refer to Appendix A. 9.9.5 Configuration: ALG233 9.9.5.1 Module Settings: ALG233 Parameter Choices Description Active Channels 1 to 16 The number of channels to be scanned. Channels are scanned in sequential, contiguous order. Channel Value Reference module. Channel Value Reference Length Read-only Depends on the number of active channels. Each channel provides two words of analog input data Level Diagnostic Reporting is enabled. Diagnostic Reference Length Read-only The amount of memory required for the channel diagnostics data. When Module Level Diagnostic Reporting is enabled, 32 bits of diagnostic rom the module. Module Status Reference Length 0, 32 The number of module status bits reported to the CPU. Data format is displayed in the following figure. 58 Note: To support this feature, Variable Mode property should be enabled in Machine Edition. PACSystems* RX3i System Manual Section 10 GFK-2314T Sept. 2019 Analog Input Modules 399 When set to 0, status reporting is disabled. To enable status reporting, set this parameter to a value other than 0. I/O Scan Set 1 through 32 Assigns the module I/O status data to a scan set defined in the CPU configuration. Determines how often the RX3i polls the data Inputs Default Force Off (default) or Hold Last State In the event of module failure or removal, this parameter specifies the state of all Channel Value References for the module. Force Off = Channel Values clear to 0. Hold Last State = Channels hold their last state.