HIMA F32100 H51A-HRS機(jī)械設(shè)備卡件
該模塊可與盒型(IC694TBB032)、擴(kuò)展盒型(IC 694TBB132)、彈簧型(IC6914TBS032)或擴(kuò)展彈簧型(IC 6914TBS132)接線(xiàn)板一起使用。擴(kuò)展接線(xiàn)板提供屏蔽布線(xiàn)所需的額外護(hù)罩深度。有關(guān)接線(xiàn)板的更多信息,請(qǐng)參閱第17章。接線(xiàn)板單獨(dú)訂購(gòu)。這些模塊必須位于RX3i通用背板中。9.10.1特點(diǎn)? 完全軟件可配置,無(wú)需設(shè)置模塊跳線(xiàn)? 全自動(dòng)校準(zhǔn)? 車(chē)載錯(cuò)誤檢查? 所有電壓和4-20mA輸入的開(kāi)路檢測(cè)? 每個(gè)通道可配置的縮放和偏移? 每個(gè)通道可選擇高報(bào)警、低報(bào)警、高高報(bào)警、低低報(bào)警檢測(cè)和報(bào)告? 模塊故障報(bào)告? 支持邏輯程序中的診斷點(diǎn)故障觸點(diǎn)? 用于未來(lái)升級(jí)的閃存? 正負(fù)變化率報(bào)警? 啟動(dòng)時(shí)自動(dòng)校準(zhǔn)? 通道報(bào)警和故障的可配置中斷? 接線(xiàn)板插入或移除檢測(cè)? 模塊支持插入和取出通電的RX3i通用背板。參見(jiàn)第2.6.4.1節(jié)熱插拔。PACSystems*RX3i系統(tǒng)手冊(cè)第10節(jié)GFK-2314T 2019年9月模擬輸入模塊410 9.10.2 LED:ALG608和ALG616模塊OK LED指示模塊狀態(tài)?,F(xiàn)場(chǎng)狀態(tài)LED指示至少一個(gè)通道上存在故障或接線(xiàn)板錯(cuò)誤。TB(端子塊)LED指示是否存在端子塊。LED由背板電源總線(xiàn)供電。LED指示模塊正常開(kāi)啟綠色:模塊正常且已配置。綠色或琥珀色緩慢閃爍:模塊正常,但未配置??焖匍W爍綠色:錯(cuò)誤。OFF:模塊故障或無(wú)背板電源現(xiàn)場(chǎng)狀態(tài)ON綠色:任何已啟用通道上無(wú)故障,且存在接線(xiàn)板。ON黃色:至少一個(gè)通道出現(xiàn)故障。OFF:接線(xiàn)板不存在或未完全就位。TB ON紅色:接線(xiàn)板不存在或未完全就位。ON綠色:存在接線(xiàn)板。OFF:模塊沒(méi)有背板電源。9.10.3及更早版本的最大4.83W-FB及更高版本的最大2.58W ALG616-EA及更早版本最大6.48W-FB和更高版本最大4.25W熱降級(jí)無(wú)分辨率參考本節(jié)中的分辨率和量程類(lèi)型表。輸入數(shù)據(jù)格式可配置為32位字段中的浮點(diǎn)IEEE 32位或16位整數(shù)濾波器選項(xiàng)8Hz、12Hz、16Hz、40Hz、200Hz、500Hz模塊掃描時(shí)間(以毫秒為單位)模塊掃描最多可包含四個(gè)采集周期。每個(gè)周期包括一組特定的通道,如“通道掃描”一節(jié)所述??倰呙钑r(shí)間取決于掃描中的采集周期數(shù)和配置的過(guò)濾器選項(xiàng)。配置的濾波器編號(hào)412正常模式噪聲抑制(單位:dB)50Hz 60Hz 8 Hz濾波器103 97定期校準(zhǔn)調(diào)整。隔離電壓接線(xiàn)板至背板/底盤(pán)光電隔離,變壓器隔離250 Vac連續(xù)/1500 Vac 1分鐘用于產(chǎn)品
This module can be used with a Box-style (IC694TBB032), Extended Boxstyle (IC694TBB132), Spring-style (IC694TBS032), or Extended Spring-style (IC694TBS132) terminal Block. Extended terminal blocks provide the extra shroud depth needed for shielded wiring. Refer to Chapter 17 for more information about Terminal Blocks. Terminal Blocks are ordered separately. These modules must be located in an RX3i Universal Backplane. 9.10.1 Features ? Completely software-configurable, no module jumpers to set ? Full auto-calibration ? On-board error-checking ? Open-circuit detection for all voltage and 4-20mA inputs ? Configurable scaling and offsets per channel ? High alarm, low alarm, high-high alarm, low-low alarm detection and reporting selectable per channel ? Module fault reporting ? Supports diagnostic point fault contacts in the logic program ? Flash memory for future upgrades ? Positive and negative Rate of Change Alarms ? Auto-calibration at startup ? Configurable interrupts for channel alarms and faults ? Terminal Block insertion or removal detection ? Module supports insertion into and removal from an RX3i Universal Backplane which is under power. Refer to Hot Insertion and Removal, Section 2.6.4.1. PACSystems* RX3i System Manual Section 10 GFK-2314T Sept. 2019 Analog Input Modules 410 9.10.2 LEDs: ALG608 & ALG616 The Module OK LED indicates module status. The Field Status LED indicates the presence of a fault on at least one channel or a terminal block error. The TB (Terminal Block) LED indicates the presence or absence of the terminal block. LEDs are powered by the backplane power bus. LED Indicates Module OK ON Green: Module OK and configured. Slow Flashing Green or Amber: Module OK but not configured. Quick Flashing Green: Error. OFF: Module is defective or no backplane power present Field Status ON Green: No faults on any enabled channel, and Terminal Block is present. ON Yellow: Fault on at least one channel. OFF: Terminal block not present or not fully seated. TB ON Red: Terminal block not present or not fully seated. ON Green: Terminal block is present. OFF: No backplane power to module. 9.10.3 & earlier 4.83W max -FB & later 2.58W max ALG616 -EA & earlier 6.48W max -FB & later 4.25W max Thermal De-rating None Resolution Refer to the table Resolution and Range Types in this section. Input Data Format Configurable as floating-point IEEE 32-bit or 16-bit integer in a 32-bit field Filter Options 8Hz, 12Hz, 16Hz, 40Hz, 200Hz, 500Hz Module Scan Time (in ms) The module scan can consist of up to four acquisition cycles. Each cycle includes a specific set of channels, as described in the section “Channel Scanning”. Total Scan Time depends on the number of acquisition cycles in the scan, and the configured filter option. Configured Filter Number 412 Normal Mode Noise Rejection in dB At 50Hz At 60Hz 8 Hz filter 103 97 periodic calibration adjustment. Isolation Voltage terminal block to backplane/chassis Opto-isolated, transformer isolated 250 Vac continuous/1500 Vac for 1 minute For product