HIMA F1101 DCS模塊卡件
和低報(bào)警? 上夾具和下夾具? 超量程和欠量程報(bào)警每個(gè)報(bào)警可按通道單獨(dú)配置,以生成診斷位狀態(tài)、故障報(bào)警或中斷報(bào)警。PACSystems*RX3i系統(tǒng)手冊(cè)第12節(jié)GFK-2314T 2019年9月模擬輸出模塊461如果命令信道高于上限值,則輸出設(shè)置為上限值,并指示上限條件。如果命令通道低于下限值,則輸出設(shè)置為下限值,并指示下限條件。在可能通過斜坡、箝位和故障條件進(jìn)行調(diào)整后,對(duì)工程單位輸出值執(zhí)行高報(bào)警和低報(bào)警檢查。PACSystems*RX3i系統(tǒng)手冊(cè)第12節(jié)GFK-2314T 2019年9月模擬輸出模塊462信道參數(shù)(續(xù))參數(shù)默認(rèn)說明診斷報(bào)告啟用如果啟用了診斷報(bào)告,則可以使用下面列出的其他參數(shù)啟用特定類型的報(bào)警。Disabled Diagnostic Reporting Enable(禁用診斷報(bào)告啟用)選項(xiàng)用于啟用將報(bào)警報(bào)告到Diagnostic reference(診斷參考)區(qū)域的參考內(nèi)存。故障報(bào)告啟用選項(xiàng)可將報(bào)警記錄到I/O故障表中。這些參數(shù)啟用或禁用通道的各個(gè)診斷功能。當(dāng)這些參數(shù)中的任何一個(gè)被啟用時(shí),模塊使用相關(guān)參數(shù)來執(zhí)行啟用的功能。例如,如果在Diagnostic Reporting Enable(診斷報(bào)告啟用)菜單中啟用了Over Range(超出范圍),則模塊將在通道的Diagnostic Reference(診斷參考)中設(shè)置Over Range位。如果這些參數(shù)中的任何一個(gè)被禁用,則模塊不會(huì)對(duì)相關(guān)報(bào)警條件做出反應(yīng)。例如,如果在故障報(bào)告啟用菜單中將低報(bào)警啟用設(shè)置為禁用,則當(dāng)通道上檢測到低報(bào)警時(shí),低報(bào)警故障不會(huì)記錄在I/O故障表中。故障報(bào)告啟用如果啟用了故障報(bào)告,下面列出的其他參數(shù)可用于啟用特定類型的故障。禁用中斷啟用禁用低報(bào)警啟用禁用高報(bào)警啟用禁用低范圍啟用禁用超范圍啟用禁用下限報(bào)警啟用禁用上限報(bào)警啟用禁用PACSystems*RX3i系統(tǒng)手冊(cè)第12節(jié)GFK-2314T 2019年9月模擬輸出模塊463 10.3.13.3.1報(bào)警和故障報(bào)告診斷報(bào)告啟用、故障報(bào)告啟用、,和中斷啟用配置參數(shù)可用于啟用各個(gè)信道報(bào)警的不同類型的響應(yīng)。默認(rèn)情況下,在每個(gè)通道上禁用所有響應(yīng)??梢詾槊總€(gè)通道配置報(bào)警啟用的任何組合。? 如果啟用了診斷報(bào)告,模塊將在為該通道配置的診斷參考地址的參考存儲(chǔ)器中報(bào)告通道報(bào)警。? 如果啟用了故障報(bào)告,則模塊會(huì)在I/O故障表中記錄每次通道報(bào)警的故障日志。? 如果啟用了中斷,警報(bào)可以觸發(fā)應(yīng)用程序中中斷塊的執(zhí)行,如下所述。10.3.13.3.2使用中斷要正確配置I/O中斷,必須在該模塊的配置文件中設(shè)置中斷啟用位。此外,應(yīng)響應(yīng)信道中斷而執(zhí)行的程序塊必須映射到對(duì)應(yīng)于該信道的參考地址。示例:在此示例中,輸出參考地址塊映射到%AQ0001-%AQ0008。
and Low Alarm ? Upper Clamp and Lower Clamp ? Over-range and Under-range Alarm Each alarm is individually configurable per channel to generate diagnostics bit status, fault alarms, or interrupt alarms. PACSystems* RX3i System Manual Section 12 GFK-2314T Sept. 2019 Analog Output Modules 461 If a channel is commanded higher than the Upper Clamp value, the output is set to the Upper Clamp value and an Upper Clamp condition is indicated. If a channel is commanded lower than the Lower Clamp value, the output is set to the Lower Clamp value and a Lower Clamp condition is indicated. The High and Low Alarm checks are performed on the engineering units output value after possibly being adjusted by ramping, clamping, and fault conditions. PACSystems* RX3i System Manual Section 12 GFK-2314T Sept. 2019 Analog Output Modules 462 Channel Parameters (Continued) Parameter Default Description Diagnostic Reporting Enable If Diagnostic Reporting is enabled, the additional parameters listed below can be used to enable specific types of alarms. Disabled Diagnostic Reporting Enable options are used to enable reference memory reporting of alarms into the Diagnostic Reference area. Fault Reporting Enable options enable fault logging of alarms into the I/O Fault Table. These parameters enable or disable the individual diagnostics features of a channel. When any of these parameters is enabled, the module uses associated parameters to perform the enabled feature. For example, if Over Range is enabled in the Diagnostic Reporting Enable menu, the module will set the Over Range bit in the Diagnostic Reference for the channel. If any of these parameters is disabled, the module does not react to the associated alarm conditions. For example, if Low Alarm Enable is set to Disabled in the Fault Reporting Enable menu, the Low Alarm fault is not logged in the I/O Fault Table when Low Alarm is detected on the channel. Fault Reporting Enable If Fault Reporting is enabled, the additional parameters listed below can be used to enable specific types of Faults. Disabled Interrupts Enable Disabled Low Alarm Enable Disabled High Alarm Enable Disabled Under Range Enable Disabled Over Range Enable Disabled Lower Clamp Alarm Enable Disabled Upper Clamp Alarm Enable Disabled PACSystems* RX3i System Manual Section 12 GFK-2314T Sept. 2019 Analog Output Modules 463 10.3.13.3.1 Alarming and Fault Reporting The Diagnostic Reporting Enable, Fault Reporting Enable, and Interrupt Enable configuration parameters can be used to enable different types of responses for individual channel alarms. By default, all responses are disabled on every channel. Any combination of alarm enables can be configured for each channel. ? If Diagnostic Reporting is enabled, the module reports channel alarms in reference memory at the Diagnostic Reference address configured for that channel. ? If Fault Reporting is enabled, the module logs a fault log in the I/O Fault table for each occurrence of a channel alarm. ? If Interrupts are enabled, an alarm can trigger execution of an Interrupt Block in the application program, as explained below. 10.3.13.3.2 Using Interrupts To properly configure an I/O Interrupt, the Interrupt enable bit or bits must be set in the configuration profile of this module. In addition, the program block that should be executed in response to the channel interrupt must be mapped to the reference address corresponding to that channel. Example: In this example, the Output Reference Address block is mapped to %AQ0001-%AQ0008.