中国大胆老太性视频HD_影视在线观看三级综合_久久精品国产首叶15_老子影院午夜伦手机不卡_亚洲伦理日韩无码_亚洲av永久无码精品_欧美暴力深喉囗交_黄色软件导航_一个人免费观看www视频二_亚洲欧美一区二区少妇

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗(yàn),請(qǐng)點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪問(wèn)瑞昌明盛自動(dòng)化設(shè)備有限公司網(wǎng)站!

圖片名

全國(guó)訂購(gòu)熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

RELIANCE S-D4007驅(qū)動(dòng)電機(jī)

RELIANCE S-D4007驅(qū)動(dòng)電機(jī)

RELIANCE S-D4007驅(qū)動(dòng)電機(jī)連接錯(cuò)誤可能由重新配置或臨時(shí)錯(cuò)誤(如電纜錯(cuò)誤)引起。如果糾正了臨時(shí)錯(cuò)誤,將自動(dòng)重新建立連接。CI854/CI854A上出現(xiàn)系統(tǒng)錯(cuò)誤,必須觸發(fā)兩個(gè)看門狗,否則模塊切換到安全狀態(tài)模式并停止PROFIBUS上的通信。與所有連接的從屬單元的連接中斷。AC 800M控制器上的ISP控制和從屬單元上的OSP控制將激活。為了使CI854/CI854A恢復(fù)到正常操作模式,您...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

RELIANCE S-D4007驅(qū)動(dòng)電機(jī)

    RELIANCE S-D4007驅(qū)動(dòng)電機(jī)

    連接錯(cuò)誤可能由重新配置或臨時(shí)錯(cuò)誤(如電纜錯(cuò)誤)引起。如果糾正了臨時(shí)錯(cuò)誤,將自動(dòng)重新建立連接。CI854/CI854A上出現(xiàn)系統(tǒng)錯(cuò)誤,必須觸發(fā)兩個(gè)看門狗,否則模塊切換到安全狀態(tài)模式并停止PROFIBUS上的通信。與所有連接的從屬單元的連接中斷。AC 800M控制器上的ISP控制和從屬單元上的OSP控制將激活。為了使CI854/CI854A恢復(fù)到正常操作模式,您必須在連接錯(cuò)誤的情況下,例如,由于電纜斷開(kāi),CI854/CI854A將保持屬于受干擾從屬單元的所有輸入的當(dāng)前值。CI854/CIL854A上的系統(tǒng)錯(cuò)誤實(shí)現(xiàn)了兩個(gè)必須觸發(fā)的看門狗,否則模塊切換到安全狀態(tài)模式并停止PROFIBUS上的通信。與所有連接的從屬單元的連接中斷。AC 800M控制器上的ISP控制和從屬單元上的OSP控制將激活。為了使CI854/CI854A恢復(fù)到正常操作模式,您必須重新設(shè)置控制器,如果是CI854A,您也可以執(zhí)行模塊的熱交換。

    A connection error can be caused by reconfiguration or a temporary error such as cable error. If a temporary error is corrected, the connection will be reestablished automatically. System Error On CI854/CI854A two watchdogs are implemented that have to be triggered otherwise the module switches into a safe state mode and stops the communication on the PROFIBUS. The connections to all connected slave units get interrupted. ISP control on the AC 800M controller and OSP control on the slave units will get active. To get the CI854/CI854A back into the normal operating mode you have to In case of a connection error, for example due to a disconnected cable, the CI854/CI854A will keep the current values for all inputs belonging to the disturbed slave unit.System Error On CI854/CI854A two watchdogs are implemented that have to be triggered otherwise the module switches into a safe state mode and stops the communication on the PROFIBUS. The connections to all connected slave units get interrupted. ISP control on the AC 800M controller and OSP control on the slave units will get active. To get the CI854/CI854A back into the normal operating mode you have toreset the controller, in case of CI854A you also can perform a hot swap of the module instead.


    GE DS3820DMCB渦輪機(jī)控制板(圖1)         GE DS3820DMCB渦輪機(jī)控制板(圖1)         GE DS3820DMCB渦輪機(jī)控制板(圖1)


    微信圖片_20220816154436.png

    微信圖片_20230209094814_副本 (2).jpg


    品牌:RELIANCE

    型號(hào):RELIANCE S-D4007驅(qū)動(dòng)電機(jī)

    質(zhì)保:365天

    成色:全新/二手





圖片名 客服

在線客服 客服一號(hào)