WOODWARD 5466-458轉(zhuǎn)速控制模塊
1.產(chǎn) 品 介 紹
品牌:WOODWARD
型號(hào)說(shuō)明:WOODWARD 5466-458轉(zhuǎn)速控制模塊
優(yōu)勢(shì):供應(yīng)進(jìn)口原裝正品,專(zhuān)業(yè)停產(chǎn)配件。
公司主營(yíng)特點(diǎn):主營(yíng)產(chǎn)品各種模塊/卡件,控制器,觸摸屏,伺服驅(qū)動(dòng)器。
2.產(chǎn) 品 詳 情 資 料:
在單一配置中安裝WOODWARD 5466-458使用以下步驟以單一配置中的PM891處理器單元:1。如果已連接,請(qǐng)從WOODWARD 5466-458處理器單元一側(cè)卸下CEX總線終端。2.將WOODWARD 5466-458處理器單元、通信接口和S800 I/O單元安裝在DIN導(dǎo)軌上。PM891的通信接口連接到處理器單元左側(cè)的CEX總線。WOODWARD 5466-458的S800 I/O單元通過(guò)處理器單元底部的光模塊總線連接。3.將總線終端重新插入離處理器單元最遠(yuǎn)的通信單元。對(duì)于CEX總線,如果使用CEX總線擴(kuò)展電纜TK850,則使用TB850終端插頭(TB851)。如果CEX總線上未使用任何單元,則不需要總線終端。4。通過(guò)在處理器單元頂部的RCU控制鏈路連接器處使用端接插頭WOODWARD 5466-458RCU控制鏈接端接器,為冗余提供端接。5.提供電纜連接:a.將電源線連接到螺絲端子L+和L-。如果適用,將SS82x的電源監(jiān)控信號(hào)連接到螺絲端子SA和SB。b.將控制網(wǎng)絡(luò)電纜連接到CN1(單連接)或CN1+CN2(冗余連接)。c.使用電纜TK212將Control Builder連接到COM4(如果需要,用于更改IP地址)。否則,將Control Builder連接到控制網(wǎng)絡(luò)。
Installing WOODWARD 5466-458 in Single Configuration Use the procedure below to install the WOODWARD 5466-458 processor unit in single configuration: 1. If already connected, remove the CEX-Bus termination from the side of theWOODWARD 5466-458 processor unit. 2. Mount the PM891 processor unit, the communication interfaces, and the S800 I/O units on the DIN-rail. The communication interfaces for PM891 is connected to the CEX-Bus to the left of the processor unit. The S800 I/O units forWOODWARD 5466-458 is connected through the optical ModuleBus at the bottom of the processor unit. 3. Re-insert the bus terminations into the communication units farthest from the processor unit. For CEX-Bus, use the TB850 termination plug (TB851, if CEX-Bus Extension cable TK850 is used. If no units are used on the CEX-Bus, no bus termination is required. 4. Provide termination for redundancy, by using the termination plug TB853 RCU Control Link Terminator, at the RCU Control Link connector at the top of the processor unit. 5. Provide cable connections: a. Connect the power leads to screw terminals L+ and L-. If applicable, connect the power supervision signals from SS82x to the screw terminals SA and SB. b. Connect the Control Network cables to CN1 (single connection) or CN1 + CN2 (redundant connection). c. Connect the Control Builder to COM4 with cable TK212 (if required, for changing an IP address). Otherwise connect the Control Builder to the Control Network.WOODWARD 5466-458
3.產(chǎn) 品 展 示
4.公 司 優(yōu) 勢(shì) 主 營(yíng) 產(chǎn) 品
5.相 關(guān) 產(chǎn) 品 展 示
本篇文章出自瑞昌明盛自動(dòng)化設(shè)備有限公司官網(wǎng),轉(zhuǎn)載請(qǐng)附上此鏈接:http://qing-ting.cn